Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.1 LAccepted-AOC | ₹68.1 L Quoted ₹69.3 L | L1 | Accepted-AOC ok |
| 2 | L2₹71.7 L+₹2.4 L (3.47%)Rejected-Finance 136 VEER COLONY BATHINDA | ₹71.7 L+₹2.4 L (3.47%) | L2 | Rejected-Finance OK |
| 3 | L3₹78.2 L+₹8.9 L (12.8%)Rejected-Finance | ₹78.2 L+₹8.9 L (12.8%) | L3 | Rejected-Finance OK |
| 4 | L4₹80.1 L+₹10.9 L (15.7%)Rejected-Finance LUDHIANA | LUDHIANA | PUNJAB | 141001 | ₹80.1 L+₹10.9 L (15.7%) | L4 | Rejected-Finance OK |
Tender Value
₹84.6 L
EMD Value
₹1.7 L
Closing Date
24 Jul 2026, 5:00 pmClosed
Er. Navjeet Singh Brar
Executive Engineer Electrical Division PWD Ldh
Replacement of 3 Nos. 13 passenger old Lifts with Three New Lifts at Judicial Courts Complex Ludhiana (Old Seven story Building)
2026_CEPW_171854_1
Bid No.4 dt 14.07.2026
Open Tender
Electrical Works
Percentage
120 days
Ludhiana
Please refer Tender documents.
22 documents required · 22 mandatory
₹5,000
₹1.7 L
12 Aug 2026
15 Jul 2026
27 Jul 2026
15 Jul 2026
24 Jul 2026
15 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, erection, testing and commissioning of 13 passengers 6 Stops ( machine room less)Gearless Monospace elevators with the following material service specification complete in all respect as per satisfaction of the Engineer in charge of the work. Specifications as per Below | - | - | - | - |
| 2 | LIFTS | - | - | - | - |
| 3 | Supply, Installation, testing and commissioning of 1 No. Lift of 13 Passangers machine room less. Type including cost of dismentalling existing lift and Capacity : Approximately 884 Kg 13 passenger
Speed: 1.0 Meter per second
Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.
Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way
Travel: Approximately 23 Meters
Serving: 6 Floors 6 Stops 6 Openings 6 Levels (All on the same side) Hoist way : 2500 mm (Wide) x 1900mm (Deep) Clear dimensions
Headroom Height (HR): upto 5000 mm beyond finished floor level of last landing
Pit Depth : 1600mm below the finish floor level of first landing
Car Size Area : Minimum 2.06 square meter amd Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof). with Honeycomb finish./ Hairline finish Car Entrance: Center Opening Automatic Doors of Stainless steel Honeycomb/Hairline finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) (In compliance with harmonised guidelines and standards for universal accessibility in india-2021 having fire rated door as per NBC), (Fire rated door minimum 120 min. Classified as EI120 acc. to E-No 81-58) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current " | - | - | - | - |
| 4 | "Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. | - | - | - | - |
| 5 | "Other Features: 1. Battery operated emergency light with rechargeable battery
2. Battery operated emergency alarm with rechargeable battery
3. Adjustable Guide shoes
4. Micro movement LED based buttons
5. Door Open and Close buttons
6. Emergency Intercom Provided inside the elevator 7. Emergency Intercom usable without the voice communication
8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication
9. Steel items, door frames sill angle's, fascia plates, spring buffers
10. Automatic phase reversal device and Phase Failure protection
11. Call registration
12. Audio & Video System installted in the lift indicating arrival at a floor
13. Manual break lever 14. Additional car gate lock
15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system
17. Kick plate/Skirting
18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close
19. Car Operating Panel
20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel
21. Phase two device fire man drive
22. Fire Man switch at main lobby
23. Car false ceiling in stainless steel
24. Pit ladder
25. Anti Nuisance car call protection
26. Door Nudging " | - | - | - | - |
| 6 | *Braille Fixtures *kick plate/skirting *Lift Announcement system to announce floor levels in English language only *Car operating panel, *Car platform constructed out of cold Rolled Grain Oriented Formed Sheets of Steel. *2 phase Device Fire Man Drive *Fire man switch at Main Lobby *Car False ceiling in Stainless Steel Finish *Pit Ladder *Motor compatible for 180 Starts Per hour *Rescue Device to bring the Elevator to a nearest Landing in case of Power failure. | - | - | - | - |
| 7 | 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.
28. The use of visually and accoustically reflective wall surace should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairements.
29. The floor of lift car should be slip resistant and have similar frictional qualities to thye floor of lift landing to decrease the risk of stumbling.
30. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight. 31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids." etc. complee in all respect desired by Engineer in charge of work.( Including cost of dismentalling existing lift). | 2 | Each | 27,51,306 | ₹55,02,612 |
| 8 | Supply, erection, testing and commissioning of 13 passengers 7 Stops ( machine room less)Gearless Monospace elevators with the following material service specification complete in all respect as per satisfaction of the Engineer in charge of the work. Specifications as per Below | - | - | - | - |
| 9 | "Supply, Installation, testing and commissioning of 1 No. Lift of 13 Passangers machine room less. Type Including cost of dismentalling existing lift.and Capacity : Approximately 884 Kg 13 passenger
Speed: 1.0 Meter per second
Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.
Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way
Travel: Approximately 28 Meters
Serving: 7 Floors 7 Stops 7 Openings 7 Levels (All on the same side) Hoist way : 2700mm (Wide) x 1950mm (Deep) Clear dimensions Height (HR): upto 5000 mm beyond finished floor level of last landing
Pit Depth : 1600mm below the finish floor level of first landing
Car Size Area : Minimum 2.06 square meter amd Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof). with Honeycomb finish/ Hairline finish Car Entrance: Center Opening Automatic Doors of Stainless steel/ Honeycomb Hairline finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) (In compliance with harmonised guidelines and standards for universal accessibility in india-2021 having fire rated door as per NBC), (Fire rated door minimum 120 min. Classified as EI120 acc. to EN. 81-58). Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current " | - | - | - | - |
| 10 | "Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 21.38 MB
Tendernotice_2.pdf
PDF • 16.87 MB
BOQ_349626.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .