Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Construction for Upgradation of Mirik Hospital from 30 to 100 bedded SD hospital, Darjeeling - SITC of Fire Detection System.
2026_WBPWD_5018551_1
WBPWD/EE/DED/e-NIT-39 of 2026-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
90 days
SILIGURI
Please refer Tender documents.
5 documents required · 5 mandatory
₹45,426
14 Aug 2026
14 Aug 2026
3 Sept 2026
14 Aug 2026
1 Sept 2026
14 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector ( VDS / UL / LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector is to be provided without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. Degree of protection as per OEM Standard. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 261 | Nos | 1,685 | ₹4,39,785 |
| 1.01 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA (Note : MCP without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). Degree of protection as per OEM Standard. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 16 | Nos | 2,195 | ₹35,120 |
| 1.02 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered /panel powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator as per NFPA (Note :Hooter without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). ( VDS / UL / LPCB / FM approved ) approved. Degree of protection as per OEM Standard (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 30 | Nos | 1,579 | ₹47,370 |
| 1.03 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector ( VDS / UL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 58 deg. C to 68 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector in the loop is to be provided without extra cost) the detectors should have built in response indicator with LED indicator.Degree of protection as per OEM Standard.
(Approved Make: Cerberus Pro / Honeywell/ Johnson Controls/Edward/Secutron/Securiton/Apollo/ Morley / Eaton / GST/Ravel/Notofire) | 6 | Nos | 1,512 | ₹9,072 |
| 2 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. (Approved Make: Cerberus Pro / Honeywell/ Johnson Controls / Edward /Secutron/Securiton/Apollo/ Morley / Eaton / GST/Ravel/Notofire) | 16 | Nos | 1,836 | ₹29,376 |
| - | Supply, Installation, Testing & Commissioning of Addressable OPC complied Monitor Modules (VDS / UL /ERTL/LPCB/FM approved) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Approved Make: Cerberus Pro / Honeywell/ Johnson Controls /Edward/Secutron/ Securiton/ Apollo / Morley / Eaton/GST/Ravel/Notofire) | 4 | Nos | 1,856 | ₹7,424 |
| - | Supply, Installation, Testing & Commissioning of Addressable Control Modules/ Relay Module ( VDS / UL / LPCB / FM approved ) for controling Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator / External fault isolator with adjustable setting parameter likes(Resistive, Inductive or capacitive) of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required (Approved Make: Cerberus Pro / Honeywell/ Johnson Controls Edward/Secutron/Securiton/ Apollo / Morley / Eaton / GST/Ravel/Notofire) | 4 | Nos | 1,677 | ₹6,708 |
| - | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box with metallic cover having two LED and Degree of protection as per OEM Standard etc. complete with all connections etc as required.
(Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire/System Sensor/Agni Suraksha ) | 32 | Nos | 146 | ₹4,672 |
| 3 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,
600/1000V rated with annealed copper conductor having
XLPE insulation, steel wire armouring & FRLS/HFFR outer
sheath complete as required. (Approved Make : Finolex/ Gloster/ RR Kable/ Polycab/ KEI ) | 6,578 | Mtr. | 161 | ₹10,59,058 |
| - | Supply, Installation, Testing & Commisioning of Microprocessor based addressable OPC complied fully networkable fire alarm control panel (VDS / UL / LPCB / FM approved ) suitable for the devices as stated in
the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 320 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store minimum 4000 log events in its memory (EPROM). The panel should have extra loop card slot for future expansion. | 1 | No. | 2,67,184 | ₹2,67,184 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
WBF2911.pdf
Tender Documents • 0.50 MB
BOQ_5089672.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].