Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹59.3 LAccepted-Finance | 1 | Accepted-Finance 1 | |
| 2 | 2₹91.7 L+₹32.4 L (54.6%)Rejected-Finance | 2 | Rejected-Finance 2 | |
| 3 | 3₹64.0 L+₹4.7 L (7.89%)Rejected-Finance DHALIWAL | FATEHGARH SAHIB | PUNJAB | 140402 | 3 | Rejected-Finance 3 | |
| 4 | 4₹64.5 L+₹5.2 L (8.79%)Rejected-Finance VILL SAKRAH PO CHAMBI TEHSIL SUNDERNAGAR DISTT MANDI HP | SUNDERNAGAR | MANDI | HIMACHAL PRADESH | 4 | Rejected-Finance 4 | |
| 5 | 5₹69.1 L+₹9.8 L (16.5%)Rejected-Finance VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | 5 | Rejected-Finance 5 |
Tender Value
₹1.0 Cr
EMD Value
₹1.4 L
Closing Date
2 May 2023, 11:00 amClosed
Executive Engineer
Jal Shakti Division Bilaspur
Augmentation of Lift Irrigaton Scheme Jukhala Ashamajari Panjaiten Bharoli Rehri Rihan in Tehsil Sadar District Bilaspur. (SH Supply and Erection of centrifugal pumping machinery along with allied accessories and laying jointing and testing of Risin
2023_HPIPH_72279_1
BLP-BLP-00736-NIT No. 1121-1220 Dated 17/04/2023
Open Tender
Civil Works
Item Rate
180 days
Sub Division Jukhala Section Jukhala
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,500
EE JSV Bilaspur
₹1.4 L
Yes
2 Jun 2023
19 Apr 2023
2 May 2023
19 Apr 2023
2 May 2023
19 Apr 2023
Amount
Providing horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistages centrifugal pump or combination of pump in series of recommended make such as Mather & Platt/KSB/Kirloskar make as per BIS-1520-1980 with upto date ammendments, read with IS: 9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels, casing ring and shaft sleaves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squarrel type drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It sho etc. and should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements. Please see the specification and others conditions in SOQ PDF format attached.
Discharge (Q) 49.11 LPS each Pump. Or 176.80 Cum/Hour (Both the pumps will run simultaneously)
Total Dynamic Head: 148.16 Meters. Make.
LWL in sump well (h). 994.10 Meters. Model.
Pump Shaft level: 997.40 Meters.
Level at discharge point. 1136.50.00 Meters.
Suction lift. 3.30 Meters.
Residual head: 3.00 Meters.
Static Head. 139.10 Meters.
Rising main.
Length. 420.00 Meters. Coupling
Dia. 350 mm Base plate
Pumping Hours. 20 Hours.
Altitude of Installation above MSL Meters
Characteristics of water. Make.
(a) Temperature 20o C Model
(b) Abient Temp. 42oC Motor rating (KW)
(c) Turbidity 80.00JTU Speed
(d) Alkalanity. Mg/Ca Co3 Insulation.
(e) Size of the solids. Mm
(f) Other.
Providing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T/Crompton/Standard/Havells make suitable Capacity Operational rating as per IS: 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTP Switches (i) Make ii) Model iii)Capacity: iv) Suitable capacity.
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- i) Drawing ii) Layour plan
M.C.B of Havells/MDS/Standard make suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date ammendments with. MCB i)Make: MEI ii) type iii) Range: iv) Rating:
Earth leakage relay of Havells/MDS/INDETEC make as per IS: 2516-1977 with upto date ammendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. E.L.R i)Make: ii) Type iii)Range: Rating
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 3842 ( Latest edition). Voltmeter. Range i) Make ii)Type: iii)Range: Amp
Power factor meter of standard make AE/L&T Rishab as per relevant IS code with upto date ammendments of suitable rating. Power factor meter. i) Type ii)Make:
Frequency meter of standard make AE/ L&T rishab as per relevant IS: Code with upto date ammendments of suitable rating. Frequency meter. i) Type ii)Make iii) Range::
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with upto date ammendments Amp. Bus Bar chamber. Make Rating Type
ICTP switches with HRC fuses of L&T/Standard/ Havells make and of suitable capacity as per IS: 4064-1978 with upto date ammendments ICTP Switches i) Type ii)Make: iii) Range:
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with upto date ammendments Three phase indicator: i) Type ii) Make iii)Rang:
Capacitor of L&T/Bajaj/Assian/Crompton make as per BIS: 2834-1986 latest with upto date ammendments to raise the power factor at site to 0.95 for direct connection to induction motor individually of requred KVAR rating according to HP offered including cable as per relevant ISI code of siemens/Gloster/IEC make form busbar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendements Capacitor i) Type ii) Make iii)Rang:
Providing suitable soft starter of MEI/ Kilburn make to BIS 8544-1979 with upto date amendments for squirrel cage motor mounted on penel board with magnetic type over load release and dashgas-pots, time legs, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS: 1248 (P=V)1983 with upto date amendements. i) Type ii) Make iii)Rang:
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 Hour Run Meter. i) Type ii) Make iii)Rang:
Providing cast iron foot valve of Leader/Kirloskar/KSB 400mm dia for the suction pipe as per IS: 4038-1986 with upto date amendements. Foot valve. Make Class Seat pressure: Materials: C.I
Providing double flanged cast iron sluice valve of Leader/ Kirloksar/Kartar and size one dia higher than pump for the delivery line of the pump and capable of with standing the normal seat pressure and as per IS: 14846-2021 with upto date amendements for Sluice valve. Make Class-PN-1.6 Seat pressure:16.32kg/cm2 Materials: C.I
Providing double flanged (Swing type) cast iron return valve of Leader/Kirloskar/KSB and one dia higher than pump having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per IS: 5312-2021 with upto date amendments. Reflux valve Make Class-PN1.6 Seat pressure:16.32kg/cm2 Materials: C.I
Providing double flanged cast iron non return valve of Leader/Kirloskar/KSB 350mm dia having bye pass arrangement for rising main and capable of with standing normal seat pressure as per IS: 5312-2021 with upto date amendements. Non Return valve Make Class:PN-1.6 Seat pressure:16.32kg/cm2 Materials: C.I
Providing 100mm dia circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1979 with upto date amendments range 0.6 of 16.32 kg/cm2 Pressure guage Make: Range: of 16.32 Kg/cm2
Providing 100mm dia circular vaccume gauge complete in all respect (vaccume gauge)
Installation of all the items appearing at Serial No. 1 to 8 as per the systematic drawing attached with the tender documents.
Providing and fixing double flanged MSERW piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 400 mm dia one dia higher the delivery of pumps Min.length = 10 Mtr (Flanged with Table-5)
(ii) Delivery pipe mm dia Min length =10 Mtr (Flanged with Table-17)
(iii)Common Header 350 mm dia Min length =10 Mtr (Flanged with Table-17)
and will extended upto 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitable size and capacity to and all other elecrtrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendmeents of Siemens/IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles,flexible, pipes solder, nut and bolts cable glands etc.laid in pipes of trenches under floor
Motor side: Suitable size cable Min length= 20 mtr
Supply side: Suitable size cable Min. length=10 mtr.
Providing and fixing double loop earthing and G.I plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm copper and G.I wire as per IS: 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Rising main: Excavation in foundation and trenches etc. ( for pipe and pits) up to all depths and in all kinds of soils such as pick work, pick jumper work, saturated soil including bailing or pumping out of water, blasting in soft/ hard rock, chiseling/wedging out of rock where blasting is prohibited, in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable materials/ soils separately and after laying, jointing and testing of pipes, returning the usable soils in 15 cm layers by ramming and watering and then disposing of all surplus excavated soil / unusable materials as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per the direction of the Engineer-in-charge.
Providing laying jointing and testing in trenches MSERW beveled edge flanged/wet welded pipes conforming to IS;ISO:3183-2012 grade L-290 or X-42 of below mentioned grade in item as per dimentions weight and test pressure mentioned therein code (Mill tolerances to be restricted with in 3%) in random length of 4 to 7 mtr including the cost of fabrication of bends by butt welding from parent tube as required at site. Only 1% joints shall be flanged joint and remaining shall be welded joints and welding of pipes will be done as per IS: 816-1969 with electrode as per IS: 814-1991 of make Advani/ Orelin (Adore)ESAH. The laying and jointing of pipes should conform to IS: 5822-1994 (Earth work in trenches, flanged joint and butt welded joints to be measured and paid for separately). The pipes shall have galvanised as per BIS: 4736. The galvanisation is done by the manufacturing firm it self complete in all respect (latest upto date amendments).
Rising main 350mm dia MSERW pipe grade L-290 X42 wall thickness 4.80 table-17 from RD 0/0 to 115=115 mtr
Rising main 350mm dia MSERW pipe grade L-290 X42 wall thickness 4.80 table-11 from RD 115 to 210=95 mtr
Rising main 350mm dia MSERW pipe grade L-290 X42 wall thickness 4.80 table-5 from RD 210 to 420 =210 Mtr
Providing fixing and welding of MS flange conforming to table as specifided below of BIS 6392-1971 (latest with upto date ammendments) welding of MS flanges on (two layere on outer face and one laye ron inner face of each flange) GMS pipe and bends on both ends (The GMS pipe to be measured and paid for separately). The welding of flanges confoming to IS: 816-1998 with eletrodes as per IS: 814-1997. Providing and fixing nuts and bolts of required size conforming to IS: 1364 including cost of gasket sheet. The thicknes sof gasket sheet should not be less than 3mm conforming to relevant BIS code IS: 2712-1998 in trenches complete in all respect and including all kinds of leads and lifts and to the entire satisfaction of the Engineer-in-charge.
350mm dia MSERW pipe flange table-17 RD 0-115Rmt@1% joint of length
350mm dia MSERW pipe flange table-11 RD 115-95 Rmt @ 1% joint of length
350mm dia MSERW pipe flange table-5 RD 210-420=210 Rmt @1% of length
Providing circumfrential butt welded joints by electrical arc welding to MSERW pipe welded in three layers of weld runs so as to achieve the minium effective thorat thickness of weld conforming to IS: 816-1969 justification by using welding electrodes conforming to IS: 814-1991 at site of work complete in all respect including manual / machincal handing of pipe in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.MSERW pipe 350mm dia Grade L-290 RD to 420 @ 99% butt welded jonts
Providing and fixing double flanged CI sluice valve 350mm dia class PN-1.6 of Leader/Kirloskar/KSB H/W rising spindal cable of with standing 16.32k/cm2 as per IS: 14846 H/W and welding of MS flanges in three layers on both faces including carriage and joint comnplete in all respect
Providing and fixing double flanged reflux valve 350mm dia class PN-1.6 of Leader/Kirloksar/KSB make capable of with standing 16.32kg/cm2 a sp er IS: 5312 Part-I H/W and welding of MS flanges in three layers on both faces including carriage and joint complete in all respect
Providing and fixing cast iron air valve 50mm dia (double ball type) of Leader/ Kirloskar/KSB make conforming to BS: 1452-90 with upto date amendements as per class PN 1-0 with stand a seat pressure 16.32kg/cm2 in rising main of 350mm dia including all leads and lifts
puneet angra
abhishek khajanchi
KUSHAL SINGH RAGHAV
Mohit Kaushal
Mr. Sanjeev Kumar
Raman Thakur Govt. Cont.
Neeraj Kumar
MNBN Enterprises
Naik Electrical Works
M/s.Pawan Kumar Sharma
Vijay Kumar C/O Vasudeva Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .