Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1 6 GOKHLE MARG 1ST FLOOR NEAR RED HILL SCHOOL LUCKNOW LUCKNOW | Admitted-Finance |
| 2 | Admitted-Finance MECHATRONICS HOUSE MUMBAI BANGALORE BYPASS HIGHWAY WARJE PUNE MAHARASHTRA 411058 | PUNE | MAHARASHTRA | 411058 | Admitted-Finance |
| 3 | Rejected-Technical 801802 SAKAR IV OPP MJ LIBERARY ELLISBRIDGE ASHRAM ROAD AHMEDABAD AHMEDABAD GUJARAT 380006 | 801802 | Rejected-Technical Technically Not Qualified |
| 4 | Rejected-Technical | Rejected-Technical Technically Not Qualified |
| 5 | Rejected-Technical 2ND ROSHAN TOWER S B SHOP BISTUPUR AREA EAST SINGHBHUM JHARKHAND | BISTUPUR | EAST SINGHBHUM | JHARKHAND | 831001 | Rejected-Technical Technically Not Qualified |
Tender Value
Refer Docs
Closing Date
11 May 2022, 3:00 pmClosed
Executive Engineer, Hydrology Project Division
Hydrology Project Division, Wainganga Nagar (Ajani), Nagpur - 440003
SCADA system for reservoir Operation of Gosikhurd Dam in Godavari Basin, including O and M For 5 Years. Tal-Pauni, Dist. Bhandara, Maharashtra
2022_PAHN_788601_1
E Tender Notice No. 13/2021-22
Open Tender
Supply, Erection and Commissioning
Item Rate
1825 days
Pauni, Dist. Bhandara
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
Nagpur (Online)
5 Jul 2022
11 Apr 2022
11 May 2022
11 Apr 2022
11 May 2022
11 Apr 2022
20 Apr 2022
Amount
Local Control System for Gosikhurd Dam .
Supply of Local Control PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & GPRS/GSM modem. Suitable 24 V DC power supply to power up PLC/RTU panel, including suitable switch mode power supply (SMPS) with 1 KVA UPS for Power back up of minimum 2 hours, 8” HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification.
Supply of Side looking Acoustic Doppler velocity meter (ADVM) with display unit for downstream discharge measurement and integration with Data logger/RTU system, Including all necessary cabling with suitable conduits & electrical fittings complete as per technical specifications.
Supply of Automated Water Level transmitter non-contact RADAR type having 35m range at Dam downstream, inflow river discharge & Early warning station. Including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.
Supply of automated Rain Gauge Stations (ARG) Equipment set with necessary hardware as per technical specifications
Supply of 2 channel input type Data logger/RTU with GSM & GPRS based telemetry for inflow stations, Dam downstream, Early warning level & ARG station, including antenna and all necessary equipment for data transmission as per technical specifications.
Supply of Bullet Camera (Fixed Type)- IP DIGITAL Night Vision (I.R.) Out door Weather Resistant, 2 Mega Pixel 2 OR4 Array/ 72 LED Colour Camera. 6 OR 8 or 12 MM (According to site suitability) 2 MP Auto Iris Lens in Elegant Metal Die Cast Housing. Outdoor weather resistant IP 66, for monitoring the gates operation complete as per technical specifications.
Supply of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Sensor, 500 metres. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling required for Dam monitoring. As per technical specifications
Supply of Automated Water Level transmitter non-contact RADAR/Ultrasonic type having 10m range for measuring sump level, Including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specification
Supply of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply at inflow, outflow discharge & Early flood warning station, as per technical specifications
Supply of intelligent field controller/ RTU as Early warning system with software development with metallic front door opening cabinet, fitted with GPRS/GSM modem with frequency-based siren at Specified locations along with industrial grade electrical fitting & cabling with suitable conduits complete, as per technical specification.
Supply of Full-bore Electromagnetic flow meter , testing, calibration, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per technical specifications for (150 mm)
Supply of Data Logger 8/RTU channel type with GSM & GPRS based telemetry including antenna and all necessary equipment for data transmission as per technical specifications.
Supply of Ultrasonic Clamp on type flowmeter for pipe discharge measurement of 1000mm -1800mm MS pipe, including GPRS/GSM modem & SIM along with required necessary mounting hardware complete as per technical specifications.
Control Room Equipment's
Supply of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. All the Electrical fittings should be Industrial Type. Including suitable switch mode power supply (SMPS) ,12” display & cabling with related remote PLC/RTU’s, complete as per technical specification
Supply, engineering and development of customized SCADA software for complete Dam automation with life time licensed version as per technical specifications.
Supply of Master server which includes Server with server Rack and industrial grade Monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 10 or higher compatible to SCADA System complete as per technical specifications.
Network Video Recorder (NVR) 32 channel 1080 P full HD, Real time recording and Reviewing in Compression Format. With HDD. along with dedicated server with sufficient Hard Drive to have memory of at least 30 days, as per technical specifications.
IT Hardware which includes required Static IP, Router , Switch, firewall system and A3 colour printer as per technical specifications
110” LED Display/ Video Wall System for monitoring of SCADA system at Control Room as per technical specifications.
Supply of 42” LED Display System as per technical specifications
Supply of laptops & 4G/3G internet dongles along with licenced version of Client SCADA software for remote viewing & monitoring of Dam automation as per technical specifications.
Supply of Laptop 15.6 " Screen, Intel core i5 processor, DDR 1 TB, Ram 8 GB and expandable upto 32 GB, internal speakers & carry case with 3 years warranty
Online 3 KVA UPS with Battery system for power back up of Dam control room equipment’s as per the technical specifications
Supply of Diesel Generator Set 10 KVA with Earth Pits for earthing & all associated accessories as per technical specifications.
Description of Work / Item(s)
Amount
Local Control System for GosikhurdDam
Installation, Testing & Commissioning of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & GPRS /GSM modem. Suitable 24 VDC power supply to power up PLC/RTU panel, including suitable switch mode power supply (SMPS) with 1 KVA UPS for Power back up of minimum 2 hours, 8” or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification
Installation testing and commissioning of Side looking Acoustic Doppler velocity meter (ADVM) with display unit for downstream discharge measurement and integration with Datalogger/RTU system, Including all necessary cabling with suitable conduits, mounting frame & electrical fittings complete as per technical specifications.
Installation, testing & Commissioning of Automated Water Level transmitter non-contact RADAR type having 35m range for Dam downstream, inflow river discharge & Early warning stations. Including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specification.
Installation, testing & Commissioning of Automated Rain Gauge Stations (ARG) Equipment set with necessary hardware as per technical specifications
Installation, testing & Commissioning of 2 channel input type Data logger/RTU with GSM & GPRS based telemetry for inflow stations, Dam downstream, Early warning level measurement & ARG station, including antenna and all necessary equipment for data transmission as per technical specifications.
Installation, Testing & Commissioning and integration with NVR located at Dam Control Room of Bullet Camera (Fixed type) - IP DIGITAL Night Vision (I.R.) Outdoor weather resistant, 2 Mega Pixel 2 OR 4 Array/ 72 LED Colour camera. 6 or 8 or 12mm (according to site suitability) 3 MP Auto Iris Lens in Elegant Metal Die Cast Housing. Outdoor weather resistant IP 66 suitable for monitoring the gates operation complete, in all respect as per Technical Specifications
Installation, Testing & Commissioning and integration with NVR located at Dam Control Room of Pan Tilt Zoom (PTZ) Cameras,36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Sensor, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling required for Dam monitoring
Installation, testing & Commissioning of Automated Water Level transmitter non-contact Ultrasonic/RADAR type having 10m range for measuring sump level. Including all necessary cabling, with suitable conduits, industrial type electrical fittings & mast complete as per technical specification.
Installation, testing & Commissioning solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply at inflow, outflow discharge & Early flood warning station, as per technical specifications.
Installation, testing & Commissioning of intelligent field controller/ RTU as Early warning system with software development with metallic front door opening cabinet, fitted with GPRS/GSM modem with frequency-based siren at Specified locations along with industrial grade electrical fitting & cabling with suitable conduits complete, as per technical specification.
Installation, testing & commissioning of Full-bore Electromagnetic flow meter , testing, calibration, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per technical specifications for (150 mm)
Installation, testing & Commissioning of Data Logger/RTU with 8 channel input type, with GSM & GPRS based telemetry including antenna and all necessary equipment for data transmission as per technical specifications
Installation, testing, Commissioning of Ultrasonic clamp on type flowmeter for pipe discharge measurement of 1800mm MS pipe, including GPRS/GSM modem & SIM along with associated Civil works, laying of signal cables, providing necessary fixtures for mounting flow sensors & required necessary mounting hardware as per technical specifications.
Installation of chain - link fencing of (5m X 5m) x 2 m along with lockable gates for external protection of Sensors and datalogger/RTU at Remote monitoring stations as per technical specifications.
Installation, Testing & Commissioning of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Including suitable switch mode power supply (SMPS) ,12” display & cabling with Industrial grade type electrical fittings for related remote PLC/RTU’s, as per technical specification.
Installation, Testing & Commissioning of customized SCADA software for complete Dam automation with life time licensed version as per technical specifications.
Installation, Testing & Commissioning of Master server with SCADA software which includes Server with server Rack and industrial grade Monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 10 or higher compatible to SCADA System complete as per technical specifications.
Installation, Testing & Commissioning of Network Video Recorder (NVR) 32 channel 1080 P full HD, Real time recording and reviewing in compression format. With HDD along with dedicated server rack mounted and industrial grade monitor with sufficient hard drive to have memory of at least 30 days as per technical specifications.
Installation, Testing & Commissioning of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 size colour printer as per technical specifications
Installation, Testing & Commissioning of 110” LED Display/Video wall system for monitoring of SCADA & Surveillance system at Control Room as per technical specifications.
Installation of 42” LED Display System as per technical specifications
Charges for 4G/3G internet dongles for five years which is to be provided along with laptops having lifetime licensed version of Client SCADA software for remote viewing & monitoring of Dam automation as per technical specifications
Installation, Testing & Commissioning of Online 3 KVA UPS with Battery system for power back up of Dam control room equipment’s as per the technical specifications
Installation, Testing & Commissioning of Diesel Generator Set of 10 KVA with 04 Earth Pits for earthing, Starter Panel, Energy meter & cabling Complete in all respects, as per technical specifications.
Charges for high speed synchronous internet connection (min. 8 mbps upload and download speed) & Static IP for Five years for Dam control room
Five Years Operation & Maintenance and Comprehensive Warranty for SCADA based Dam automation system as per Price schedule after final acceptance of SCADA & Surveillance system. This includes replacement of material & consumable as & when required at bidders’ cost and also necessary up gradation of SCADA system. The cost of Communication for GPRS & SIM charges for data transmission & other related charges. Minimum one Service Engineer shall be placed at Dam Control Room for Operation of SCADA & Surveillance system.
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC &SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment & SCADA configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies.
Mechatronics Systems Pvt Ltd
Bips Systems Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .