Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹3.2 CrAWARDED | ₹3.2 Cr | AWARDED |
Tender Value
₹3.7 Cr
EMD Value
₹5.5 L
Closing Date
2 Apr 2025, 4:00 pmClosed
Karnataka Neeravari Nigam Limited
Third party consultants for Inspection, testing, quality control & monitoring and construction supervision for the work of Providing community irrigation facility to 9950 Ha of leftout area in Athani Taluk, Belagavi District Including Filling up of 17 Nos MI/ZP tanks by lifting water from Krishna River near Zunjurwad Village of Athani taluk Belgaum District for the work of Ammajeshawari (Kottalagi) LIS Phase-I
KNNL/2024-25/OW/WORK_INDENT2591
KNNL/2024-25/OW/WORK_INDENT2591
Open
Other Works
Two Tender Document System(Two Cover)
KNNL Division HBC Div Athani
₹5,000
₹5.5 L
8 Sept 2026
25 Mar 2025
4 Apr 2025
1 Apr 2025
29 Mar 2025
Third party consultants for Inspection, testing, quality control & monitoring and construction supervision for the work of Providing community irrigation facility to 9950 Ha of leftout area in Athani Taluk, Belagavi District Including Filling up of 17 Nos MI/ZP tanks by lifting water from Krishna River near Zunjurwad Village of Athani taluk Belgaum District for the work of Ammajeshawari (Kottalagi) LIS Phase-I
TESTS ON SOIL SAMPLE Conducting Mechanical analysis (Sieve test) as per IS Codes as directed by Engineer-In-incharge
Conducting Liqid limit and plastic limit test as per IS Codes as directed by Engineer-In-incharge
Conducting Specific gravity test as per IS Codes as directed by Engineer-In-incharge
Conducting Standard compaction test [OMC % MDD] as per IS Codes as directed by Engineer-In-incharge
Conducting Traxial shear at OMC/in-situ condition test as per IS Codes as directed by Engineer-In-incharge
Conducting Permeability Test at OMCas per IS Codes as directed by Engineer-In-incharge
Conducting Triaxial shear at saturation as per IS Codes as directed by Engineer-In-incharge
Conducting Swelling pressure test as per IS Codes as directed by Engineer-In-incharge
Conducting Consolidation test as per IS Codes as directed by Engineer-In-incharge
TESTS ON CEMENT SAMPLE Conducting Consistency test as per IS Codes as directed by Engineer-In-incharge
Conducting Fineness test as per IS Codes as directed by Engineer-In-incharge
Conducting Soundness test by Le-Chatellier method as per IS Codes as directed by Engineer-In-incharge
Conducting Initial and final Setting time [for set of three nos] as per IS Codes as directed by Engineer-In-incharge
Conducting compression test on cement concrete cubes as per IS Codes as directed by Engineer-In-incharge
TESTS ON FINE AGGREGATE Conducting Sieve analysis Test as per IS Codes as directed by Engineer-In-incharge
Conducting Particle finer than 75 micron test as per IS Codes as directed by Engineer-In-incharge
Conducting Specific gravity, bulk density, bulking & moixture content and water absorption test as per IS Codes as directed by Engineer-In-incharge
Conducting Fineness Modulus test as per IS Codes as directed by Engineer-In-incharge
Conducting Silt content test as per IS Codes as directed by Engineer-In-incharge
TESTS ON COURSE AGGREGATE Conducting Sieve analysis Test as per IS Codes as directed by Engineer-In-incharge
Conducting Particle finer than 75 micron test as per IS Codes as directed by Engineer-In-incharge
Conducting Specific gravity, bulk density.test as per IS Codes as directed by Engineer-In-incharge
Conducting Aggregate Impact value test as per IS Codes as directed by Engineer-In-incharge
Conducting Aggregate crushing value/10% fine value test as per IS Codes as directed by Engineer-In-incharge
Conducting Abrasion Value test as per IS Codes as directed by Engineer-In-incharge
Conducting Crushing Value test as per IS Codes as directed by Engineer-In-incharge
Conducting Stripping Value test as per IS Codes as directed by Engineer-In-incharge
Conducting lab test on steel (round bar/twisted) for determining tensile strength, elongation, 0.2% proof stress and unit weight of up to 20mm dia as per IS Codes as directed by Engineer-In-incharg...
Conducting lab test on steel (round bar/twisted) for determining tensile strength, elongation, 0.2% proof stress and unit weight of Dia nore than 20mm as per IS Codes as directed by Engineer-In-incha...
Casting and testing for compressive strength of Cement Concrete Cubes by normal curing method as per IS Codes as directed by Engineer-In-incharge
Extraction and Conducting Compression test of cement concrete core samples including capping &etc. and furnishing the reports. (for set of three cores) Up to 100 mm core diameter (4 inch) as per IS Co...
Conducting Slump test as per IS Codes as directed by Engineer-In-incharge
NON DESTRUCTIVE TESTING Conducting non-destructing test using rebound hammer at site as per IS Codes as directed by Engineer-In-incharge
Conducting Ultrasonic pulse velocity test as per IS Codes as directed by Engineer-In-incharge
TESTS ON BITUMEN Conducting Penetration test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Specific gravity test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Ductility test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Flash and Fire point test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Softening point test at site as per IS Codes as directed by Engineer-In-incharge
TESTS ON BITUMEN CONCRETE MIX Conducting Sieve Analysis test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Impact Value test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Abrasion Value test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Flakiness & Elongation Index ,Water Absorption & Density test at site as per IS Codes as directed by Engineer-In-incharge
Conducting Bitumin content test at site as per IS Codes as directed by Engineer-In-incharge
TESTS ON GRANULAR SUB BASE Conducting Sieve Analysis test at site as per IS Codes as directed by Engineer-In-incharge
TESTS ON WET MIX MECADAM (WMM) Conducting Sieve Analysis test at site as per IS Codes as directed by Engineer-In-incharge
TEST ON PIPES Conducting Test on pipe shell thickness as per IS Codes as directed by Engineer-In-incharge
Conducting Test On Paint Thickness Of M.S Pipe as per IS Codes as directed by Engineer-In-incharge
Test On outer surface layer Of M.S Pipe Conducting Pull off adhesion test as per IS Codes as directed by Engineer-In-incharge
Conducting Gauge test as per IS Codes as directed by Engineer-In-incharge
Conducting Water Absorption test as per IS Codes as directed by Engineer-In-incharge
Conducting Cold Flexibility test as per IS Codes as directed by Engineer-In-incharge
Conducting Ultrasonic pulse velocity test as per IS Codes as directed by Engineer-In-incharge
Conducting Radiography test as per IS Codes as directed by Engineer-In-incharge
MEASUREMENT/BILLING SERVICES Engaging PROJECT MANAGER (Engineering Graduate Employee). as directed by Engineer-In-incharge
Engaging Field surveyour / Total station operator (Engineering Graduate Employee) as directed by Engineer-In-incharge
Engaging LAB TECHNICIANS (Engineering Graduate Employee) as directed by Engineer-In-incharge
Engaging HELPER LABORATORY as directed by Engineer-In-incharge
Engaging FIELD ENGINEERS (Diploma in Engineering Employee) as directed by Engineer-In-incharge
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .