Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.2 L
Closing Date
11 Oct 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER ELECTRIC DIVISION BARAMULLA
EXECUTIVE ENGINEER ELECTRIC DIVISION BARAMULLA
Installation of Tri-Vector Meter and restoration of normal power supply to I.T.I. Kralhal
2021_PDD_140221_1
EDB/84
Open Tender
Electrical Works
Turn-key
30 days
Installation of Tri-Vector Meter and restoration o
Please refer Tender documents.
6 documents required · 6 mandatory
₹201
EXECUTIVE ENGINEER ELECTRIC DIVISION BARAMULLA
Exempted
13 Oct 2021
18 Sept 2021
13 Oct 2021
18 Sept 2021
11 Oct 2021
20 Sept 2021
18 Sept 2021 - 20 Sept 2021
180 days
Supply, Carriage up to site, Erection, testing and commissioning of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long )
Supply ,Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (50mm2 ACSR Conductor)
Supply, Carriage up to site, and fixing of GI Channel Iron x-arm 9' long 100x50x6mm 02 No. including suitable clamps/collars
Supply, Carriage up to site, and fixing of GI Channel Iron x-arm 9' long 75x40x6mm 08 Nos including suitable clamps/collars .
Supply, Carriage up to site, and fixing of GI V cross arm with top bracket ,(75X40X6mm) 05 No. including Collars (50X8mm) 03 No.
Supply, Carriage up to site, and fixing of GI Angle iron (50X50X6), 9'long 02 Nos for Transformer belting including suitable clamps/collars
Supply, Carriage up to site, and fixing of supported structure fabricated of GI Pipes 5 inch Dia, 14 ft. Long (01 No.)
Supply, Carriage up to site, Installation, testing and Commissioning of 11 KV Pin Insulators (Porcelain with Pins (5KN)
Supply, Carriage up to site, Installation, testing and Commissioning of 11 kV G.O AB Switch , 3-phase, 3 pole 400A polymer Stn. Type
Supply, Carriage up to site, Installation, testing and Commissioning of 11 kV D O Fuse 3phase 400Apolymer Stn. Type
Supply, Carriage up to site, Installation, testing and Commissioning of Gapless Surge Arrestor,9 KV ,10 KA ,LA with Porcelain Stn. Type
Supply, Carriage up to site, Installation, testing and Commissioning of LT Fuse Sets (Pre-fabricated)
Supply, Carriage up to site, laying ,stringing, tensioning , binding of 1.1 KV grade, 300 sq-mm 1-core PVC Cable
Supply, Carriage up to site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply, Carriage up to site, and fixing of Galvanised nuts and bolts of sizes
Supply, Carriage up to site, Installation, testing and Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2 Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Providing, carriage, transportation, Installation etc. Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50 mmx6 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover.
Shifting Charges of sub station
Providing, carriage, transportation, Installation etc. of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole (Pit 600x600x1600 mm) for 9 MTR ST Pole
Providing & Painting of Poles with one coats of Red Oxide and two coat of aluminium paint
Supply, Carriage up to site, Installation, testing and Commissioning of danger Plates
Supply, Carriage up to site, Installation, testing and Commissioning of anti-climbing devices
Supply, Carriage up to site, installation, testing and commissioning of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semisynthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door.
Supply, Carriage up to site, installation, testing and commissioning of Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5. The CT ratio shall be as under: i. 2.5 /5 for 25kVA DT ii. 5/5 for 63kVA DT iii. 7.5/5 for 100kVA DT iv. 15/5 for 200kVA DT v. 20/5 for 250kVA DT vi. 25/5 for 400kVA DT vii. 50/5 for 630kVA DT viii. 75/5 for 1MVA DT
Supply, Carriage up to site, installation, testing and commissioning of 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute.
Supply, Carriage up to site, installation, testing and commissioning of Bus Bar details: CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape
Supply, Carriage up to site, installation, testing and commissioning of PVC Copper wire flexible multi-strand of required size for secondary connections for CTwiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB).
Supply, Carriage up to site, installation, testing and commissioning of Copper Lugs preferably ring type duly crimped for termination of wires and tapes
Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. The CTs, PT meter and 11kV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm2
Supply, Carriage up to site, installation, testing and commissioning of 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS Compliant Category 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure, ABB)
Supply, Carriage up to site, installation, testing and commissioning of Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartment
Supply, Carriage up to site, installation, testing and commissioning of Pedestal made out of MS Channel of size 75 x 40 mm or angle iron of size 65 x 65 x 5 mm,duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts
Supply, Carriage up to site, installation, testing and commissioning of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixing where ever required.
Supply, Carriage up to site, installation, testing and commissioning of Cable termination kits suitable for 3 x 35 mm2 XLPE Cable (indoor/outdoor)
Earthing 40 mm GI Pipe, 2.5 mtr for metering unit. Earthing of meteringcubicle through two No 25 x 5 mm flat iron.
Supply, Carriage up to site, Installation, testing and Commissioning of 4 Pole MCCB 400 Amp (reputed make),
M/S H.B.C ENGINEERING
M/S BASHIR AHMAD CHALKOO
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .