| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC H NO 89 BEHIND DD LEH UT LADAKH | LEH | LEH | LADAKH | 194101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.4 L+₹44,420 (1.39%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance L2 | |
| 3 | L3₹35.0 L+₹3.0 L (9.37%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | - | Rejected-Technical No not enlisted in requsite category |
Tender Value
₹32.1 L
EMD Value
₹64,200
Closing Date
15 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG
GE-KHU-20-2022-23 PROVN OD 04 X OIL FIRED HEATING SYSTEM AND INSULATION WALL TO BUILDING IN 8 MTN DIV PRO UNIT UNDER GE KHUMBATHANG
2022_MES_558149_2
GE/KHU-20/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹64,200
14 Feb 2023
25 Nov 2022
16 Dec 2022
25 Nov 2022
15 Dec 2022
3 Dec 2022
Amount
Supply, installation and commissioning of stand alone air heater for space heating of capacity 25000 Kcal /Hr suitable for operation with diesel fuel complete with fuel filter, burner, blower fan, blower motor, automatic digital temperature controller, control panel (prewired type complete with audio/visual controls, safety interlocks , MCB, overload relays, timers and alarm hooters), blower fan gaurd , fuel tank all as per standard specifications of manufacturer complete all as specified and directed by Engr-in-Charge. The air heater suitable for following specifications:- (a) Hot air delivery of minimum 1750 Cum/Hr at 80 degree centigrade (b) The motor should be capable of operating on single phase supply. Note:- Make -Alfatherm/ Maktek/Technolima/Munters (c) The complete unit shall be mounted on PCC plateform of suitable size as recommended by the manufacturer. The unit shall be installed outdoor. The chimney to carry out the exhaust beyond roof level all as per recommendation of manufactures shall be provided by the contractor. (d) Make and Model to be offered by the contractor shall be got approved from GE before procurement. (e) Voltage regulator for burner assembly shall also be supplied with air heater. Voltage regulators shall be supplied by the manufacturers of the air heater. (f) MS fuel tank of capacity 100 Ltrs including mounting stand of suitable height shall be provided by the manufactures within the overall cost quoted. (g) All piping network from fuel tank to standalone heaters shall be included in the overall cost quoted complete all as specified and directed.
Supply, fabrication, installation and commissioning of air ducting made of Galvanised steel sheet metal casing cross section 400x400mm (24 gauge) alongwith 50 mm glass wool insulation with neoprene rubber gaskets, Elbow, split dampers, vanes,hangers, supports etc. complete all as specified and directed by Engr-in-Charge.
Supply, fabrication, installation and commissioning of return air ducting made of Galvanised steel sheet metal casing cross section 400x400mm (24 gauge) with neoprene rubber gaskets, Elbow, split dampers, vanes,hangers, supports etc. complete all as specified and directed by Engr-in-Charge.
Supply, fabrication, installation and commissioning of aluminium cladding of any ducting size as required at site complete all as specified and directed by Engr-in-Charge.
M & L for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith accessories with 2.5 Sq mm FRLS PVC insulated unsheathed copper conductor cable as earthing and connected to common earth complete all as specified and directed by Engr-in-Charge.
S & F metal enclosure (DB 08 way), triple pole and neutral with 200 amps rated bus bar, 240 volts double door including neutral bus bar and earth bar complete all as specified and directed by Engr-in-Charge.
M&L for Circuit breaker single pole, 5 to 40 Amp 240 volt C curve 10 KA, IP 20 complete all as specified and directed incl taking down old one complete all as specified and directed by Engr-in-Charge.
S & F MCCB 415 Volt, 16 KA 4 Pole 100 Amps capacity IP 20 complete all as specified and directed by Engr-in-Charge.
M & L switch socket combination switch socket outlet 3 pin, 16 amp flush type complete all as specified and directed by Engr-in-Charge.
S&F two single core 6 sq mm for Sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping/ pvc conduit with fixing accessories including one run of 6 Sq mm copper conductor complete all as specified and directed by Engr-in-Charge. Note - Two runs of 06 Sq mm cable, one run of 6 Sq mm earth cable and one run of PVC casing Capping shall be measured as one running meter.
Material and labour earthing complete with galvanized steel earth plate 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.5 mtr filled around with 15 cm thick alternate layers of charcoal dust and salt and connected to earth lead wire 4mm dia (8 SWG) by means of bolt, nut and check nuts and washers of galvanized iron or steel and thimble and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, pcc 1:3:6 type C-1 in chambers RCC 1:2:4 type B-1 in pit cover reinforced with 8 mm dia deformed bars 15cm center to center both ways all as shown in electric plate No 3 of MES SSR Part I complete all as specified and directed by Engr-in-Charge.
M&L second class soft wood, plain fillets, square, rectangular or triangular in section of area exc 13 and n exc 25 Sqcm clean sawn, secured with screw or brads complete all as specified and directed by Engr-in-Charge.
M&L second class soft wood, plain fillets, square, rectangular or triangular in section of area exc 6 and n exc 13 Sqcm clean sawn, secured with screw or brads complete all as specified and directed by Engr-in-Charge.
M&L second class soft wood, plain fillets, square, rectangular or triangular in section of area n exc 6 Sqcm clean sawn, secured with screw or brads complete all as specified and directed by Engr-in-Charge.
M&L 12 mm thick, prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in walls complete all as specified and directed by Engr-in-Charge.
S&F 50 mm thick bonded mineral wool blankets slab made from rock, density 48 kg/cum and fixed as per manufacturer’s instructions complete all as specified and directed by Engr-in-Charge.
SUMEET TRADING CORPORATION
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .