Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹3.0 LAdmitted-Finance 112 21 A 2 K N MUKHERJEE ROAD P O TALPUKUR BARRACKPORE 24 PGS N | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | H1 | Admitted-Finance | |
| 2 | H2₹3.0 L−₹2,980 (0.98%)Admitted-Finance 159 KAILASH GHOSHI ROAD KOLKATA WEST BENGAL 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | H2 | Admitted-Finance | |
| 3 | H3₹2.9 L−₹12,363 (4.06%)Admitted-Finance | H3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | POWER INDIA H2 | MIK ENTERPRISES H1 | M/S STARLIGHT & CO H3 |
|---|---|---|---|---|---|---|
| 1.00 | Tripping the OCB manually for disconnection of the 11 KV electrical connections from the HT Switchgear Panel and isolation of power cables from the panel terminal including necessary safety arrangement. | 1 | Item | 5,202 ₹6,138 | 5,253 ₹6,199 | 5,040 ₹5,947 Lowest |
| 2.00 | Dismantling and drawing out of the OCB (Oil Circuit Breaker) from the panel housing and shifting to a clean working space for necessary overhauling. | 1 | Item | 5,573 ₹6,576 | 5,628 ₹6,641 | 5,400 ₹6,372 Lowest |
| 3.00 | Removal of 3 nos. faulty CTs from the OCB using necessary tools and tackles. | 1 | Item | 3,385 ₹3,994 | 3,419 ₹4,034 | 3,280 ₹3,870 Lowest |
| 4.00 | Supply,delivery,fitting and fixing of 11KV grade Resin Cast Current Transformer, Ratio: 50/5A, Class: 5P10, Burden: 15VA, conforming to IS standards of any reputed make. | 3 | Nos. | 43,818 ₹1,55,116 | 44,251 ₹1,56,649 | 42,455 ₹1,50,291 Lowest |
| 5.00 | Thorough overhauling of OCB mechanism, checking of alignment, lubrication, and replacement of arcing contacts to ensure zero millivolt drop. | 1 | Item | 24,234 ₹28,596 | 24,473 ₹28,878 | 23,480 ₹27,706 Lowest |
| 6.00 | Inspection and servicing of HT Busbars including checking of tightness, cleaning of supports/insulators, and applying contact grease. | 1 | Item | 9,103 ₹10,742 | 9,193 ₹10,848 | 8,820 ₹10,408 Lowest |
| 7.00 | Dehydration and filtration of OCB insulating oil to achieve dielectric strength > 50KV, including top-up with fresh oil to desired level. | 1 | Item | 16,834 ₹19,864 | 17,000 ₹20,060 | 16,310 ₹19,246 Lowest |
| 8.00 | Complete replacement of panel control wiring using 2.5 sq. mm copper flexible FRLS wire with printed ferruling and heavy-duty lugs. | 1 | Item | 12,282 ₹14,493 | 12,403 ₹14,636 | 11,900 ₹14,042 Lowest |
| 9.00 | Supply,fitting and fixing of shunt trip coil. | 1 | Item | 2,941 ₹3,470 | 2,971 ₹3,506 | 2,850 ₹3,363 Lowest |
| 10.00 | Measurement of Insulation Resistance (Megger Test) and High Voltage (Hi-Pot) testing of the panel assembly as per IS standards. | 1 | Item | 14,749 ₹17,404 | 14,894 ₹17,575 | 14,290 ₹16,862 Lowest |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
1 Aug 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy. CE ( M/S and D)
5, S.N Banerjee Road, Kolkata ,700013.
Restoration of HT Power including repair and replacement of damaged components of 11KV/400A Incomer OCB, and allied works at Keorapukur STP Old PS under Kudghat Unit/S and D Department.
2026_KMC_1034029_1
KMC/S_D/KGPS-07/26-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
Kudghat
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹6,000
12 Aug 2026
24 Jul 2026
4 Aug 2026
24 Jul 2026
1 Aug 2026
24 Jul 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Tripping the OCB manually for disconnection of the 11 KV electrical connections from the HT Switchgear Panel and isolation of power cables from the panel terminal including necessary safety arrangement. | 1 | Item | 5,100 | ₹5,100 |
| 2 | Dismantling and drawing out of the OCB (Oil Circuit Breaker) from the panel housing and shifting to a clean working space for necessary overhauling. | 1 | Item | 5,500 | ₹5,500 |
| 3 | Removal of 3 nos. faulty CTs from the OCB using necessary tools and tackles. | 1 | Item | 3,230 | ₹3,230 |
| 4 | Supply,delivery,fitting and fixing of 11KV grade Resin Cast Current Transformer, Ratio: 50/5A, Class: 5P10, Burden: 15VA, conforming to IS standards of any reputed make. | 3 | Nos. | 42,560 | ₹1,27,680 |
| 5 | Thorough overhauling of OCB mechanism, checking of alignment, lubrication, and replacement of arcing contacts to ensure zero millivolt drop. | 1 | Item | 23,500 | ₹23,500 |
| 6 | Inspection and servicing of HT Busbars including checking of tightness, cleaning of supports/insulators, and applying contact grease. | 1 | Item | 8,750 | ₹8,750 |
| 7 | Dehydration and filtration of OCB insulating oil to achieve dielectric strength > 50KV, including top-up with fresh oil to desired level. | 1 | Item | 16,250 | ₹16,250 |
| 8 | Complete replacement of panel control wiring using 2.5 sq. mm copper flexible FRLS wire with printed ferruling and heavy-duty lugs. | 1 | Item | 11,850 | ₹11,850 |
| 9 | Supply,fitting and fixing of shunt trip coil. | 1 | Item | 2,960 | ₹2,960 |
| 10 | Measurement of Insulation Resistance (Megger Test) and High Voltage (Hi-Pot) testing of the panel assembly as per IS standards. | 1 | Item | 14,330 | ₹14,330 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
Tendernotice_2.pdf
PDF • 0.80 MB
BOQ_2539567.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .