Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L1 | Accepted-AOC ACCEPTED LOWEST BIDDER L1 | |
| 2 | L2₹23.9 L+₹2.2 L (10.1%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L2 | Rejected-Finance Being rejected L2 | |
| 3 | L3₹31.0 L+₹9.3 L (42.8%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being rejected L3 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jan 2024, 6:00 pmClosed
SHRI ABHINANDAN KUMAR MISHRA EE IDSE
GE (SOUTH) AMBALA CANTT
CA NO GE SOUTH AMB 53 2023 2024 REPAIR REPLACEMENT OF EARTHING LOAD LINES AND CERTAIN INTERNAL ELECTRIFICATION WORKS AT OTM AND MARRIED ACCN OF SOUTHERN ZONE C2 SECTOR UNDER GE (SOUTH) AMBALA CANTT
2023_MES_631323_1
GE(SOUTH)/AMB-53/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹80,000
Yes
31 Jan 2024
6 Dec 2023
4 Jan 2024
6 Dec 2023
2 Jan 2024
20 Dec 2023
6 Dec 2023 - 19 Dec 2023
Amount
Dismantling/taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 25mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 2.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 2.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 2.00 here in before but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fixing of modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular switches, one way, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
Supply and fixing of modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fixing of modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed.
Supply and fixing of fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing of modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular blanking plate 1 module complete all as specified and directed.
Supply and fixing of ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing of door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Material and labour for concealed point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, stove enameled steel conduit not less than 25 mm dia with FRLSH accessories, concealed and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel flame proof juction boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch complete all as specified and directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 15.00 above but for socket out let point 5 Amps on same board,complete all as specified and directed.
Description all as per item No 15.00 above but for socket out let point 5 Amps on independent board,complete all as specified and directed.
Supply and fixing of flame proof switch rotary type with termination box in LM6, 16 Amps, single pole, 250 volt, complete all as specified and directed.
Supply and fixing of flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 volt, 2P+earth complete all as specified and directed.
Supply and fixing of flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 volt, 2P+earth complete all as specified and directed.
Supply and fixing of in repair of sheet metal enclosure SP with two pin and earth plug and socket including top with one single pole, MCB 20/32 Amps, 'B' curve, 240 volts complete all as specified and directed.
Supply and fixing of flame proof LED light fitting 1 x 20 Watt, CIMFR certified recommended for gas/ vapor group of IIA & IIB, Zone 1 & 2 and IP 65/66 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing of flame proof LED light fitting 2 x 20 Watt, CIMFR certified recommended for gas/ vapor group of IIA & IIB, Zone 1 & 2 and IP 65/66 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing of flame proof cum water proof LED bulk head well glass light fitting of not less than 10 Watt, IP 66 protection of cast aluminum alloy material and impact resistant toughened 'A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing of LED light fitting 1x20W, 220V, AC with aluminium housing with batten with driver, holder including 20W LED tube light for connecting up with three core flexible copper conductor cable with suitable size from ceiling rose to connector complete all as specified and directed.
Supply and fixing of LED light fitting 1x20W, 220V, AC with engineering plastic housing with batten with driver, holder including 20W LED tube light for connecting up with three core flexible copper conductor cable with suitable size from ceiling rose to connector complete all as specified and directed.
Supply and fixing of channel for fixing of LED tube rod of CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. (Tube rod shall be measured and paid for separately). NOTE : - Channel must be get approved from Engineer in charge to check fesibilty i.e. one end contact or two end contact.
Supply and fixing of 18 Watt/20 Watt LED tube light two end contact, fitting should have lumen output more than 100 lumens per watt, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. NOTE : - Tube rod must be get approved from Engineer in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
Supply and fixing of batten with surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of LED bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and directed.
Supply and fixing of LED lamp 9 watt B-22 base complete including taking down old existing lamp any type complete all as specified and directed.
Supply and fixing of LED lamp 12 watt B-22 base complete including taking down old existing lamp any type complete all as specified and directed.
Supply and fixing recess/ surface mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Disconnecting and taking down old existing recess/surface mounting ceiling light fitting of any description and in any position and supply and fixing surface/ recess mounting LED slim square/round down lighter 12 W LED with high efficient LEDs glare free opal diffuser madeup of PDC AL with IP 20 Protection including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Supply and fixing in repair bracket for security light made up of 25/40 mm dia, 0.60 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing of LED security light luminaire 30 watt, pressure die cast aluminum housing, toughened heat resistant glass, IP 66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of LED security light luminaire 45 watt, pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of inverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Material and labour for taking down existing light fitting any type / size/make / capacity and refix the same after minor repair/ cleaning including replacement of connection wire with 0.75sqmm copper wire twin core for connection from ceiling rose to light fitting all as specified and directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and supply and fixing aesthetically designed wall bracket light in B22 holder with 9 watt LED lamp warm white & clear diffuser including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Supply and fixing of post top lantern LED 30W warm white, cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed. NOTE: - LED (Cool white or warm white) must get approved by Engineer-in-Charge.
Disconnecting and taking down old existing Bollard light fitting of any description and in any position and supply and fixing LED bollard light fittings with aluminium pipe housing swith glare fee PMMA diffuser , IP 65 protection ofheight not less than 1000 mm with and including 15-20 Watt LED including base frame made up of sheet metal and connecting up with three core 1.5 sqmm flexible copper conductor cable including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed. NOTE : LED (Cool white or warm white) must get approved from Engineer-in-Charge.
Disconnecting and taking down old existing Bollard light fitting of any description and in any position and supply and fixing LED bollard light fittings with aluminium pipe housing swith glare fee PMMA diffuser , IP 65 protection ofheight not less than 600 mm with and including 10 watt LED including base frame made up of sheet metal and connecting up with three core 1.5 sqmm flexible copper conductor cable including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed. NOTE : LED (Cool white or warm white) must get approved from Engineer-in-Charge.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4.0 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall / pillars / columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6.0 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and as directed. NOTE: - (i) Earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. (ii) On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 125 Amps, 25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 100 Amps, 16 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of SPN distibution board 8 way,double door , IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing in repair of MCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal adjustable type complete all as specified and as directed.
Supply and fixing in repair of MCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal adjustable type complete all as specified and as directed.
Supply and fixing in repair of sheet steel enclosure with separate busbar chamber for cable termination with and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25KA, 125 Amps, thermal release type, complete all as specified and directed.
Supply and fixing in repair of sheet steel enclosure with separate busbar chamber for cable termination with and including MCCB four pole, 240 volts, 50Hz, breaking capacity 16KA, 100 Amps, thermal release type, complete all as specified and directed.
Supply and fixing in repair of metal clad plug (only metal top) of 20A, 2P+E, 240 volts, AC, complete all as specified and directed.
Supply and fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 6 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
Supply and fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
Material and labour for attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit incl no light , earth leakage, short cicuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centre alongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working days for rectification of complaints and resubmit the dockets after completion of each job of each job on the same day. If contractor is failed to submit the docket within 48 hours after issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00 per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates.
Supply only switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply, ISI Marked, complete all as specified and as directed.
Supply only switch, single pole two way 6 Amps, 230 volts AC circuit complete all as specified and as directed.
Supply only switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, complete all as specified and as directed.
Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and as directed.
Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as specified and as directed.
Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed.
Supply only ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed.
Supply only fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and as directed.
Supply only door bell electric ,ding dong /musical| type, single phase 230 volts, complete all as specified and as directed.
Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
Supply only switch modular 6 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply only switch modular 16 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply only socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply only fan regulator step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply only bell push modular with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Sipply only Fan condenser 2.5 mfd complete all as specified and as directed.
Supply only Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI marked complete all as specified and as directed.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked complete all as specified and as directed.
Supply only MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series complete all as specified and as directed.
Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series complete all as specified and as directed.
Supply and fixing in repair of driver for bollard light, recess/ceiling light of 10 to 20 watt of suitable size and easy installation as per existing make complete all as specified and directed.
Supply and fixing in repair of driver for ceiling light, post top lantern and security light of 30 to 45 watt of suitable size and easy installation as per existing make complete all as specified and directed.
NOTE:- Amount of credit of Rs. 72,009.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Mohinder Pal and Sons
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .