Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹2.0 L+₹2,468.71 (1.27%)Admitted-Fee/PreQual/Technical/Finance KUNNATH CHALI THALAMUNDA KOODALI | KOODALI | KANNUR | KERALA | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Madhusuthanan K P L2 | MUHAMMAD L1 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 35 | point | 1,430 ₹50,050 Lowest | 1,500 ₹52,500 |
| 1.00 | OD77402/2026-2027:Supply, Conveyance installation testing and commissioning of Led Recessed mounted 600*600 mm Luminaire having power consumption not more than 30W and light output not less than 3600 Lumens with System efficacy> 120 Lumen/Watt . Luminaire Housing Shall be made from single piece CRCA body without welding. The Luminaire should be having minimum 50000 Burning hours with CRI ≥80, SDCM<5 and 1 Co-related color temperature (CCT) of 6500K.The luminaire must have 4KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,EMI/EMC Compliant, Operating voltage range 140-270V with High voltage cutoff@325 ± 15V with Auto restart feature. Luminaire and driver shall be separately BIS approved of same make .all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required | 14 | each | 3,001.59 ₹42,022.26 Lowest | 3,050 ₹42,700 |
| 1.00 | OD77403/2026-2027: Supply, Conveyance installation testing and commissioning of LED Downlight Luminaire having power consumption not more than 18W and light output not less than 2000 Lumens with System efficacy> 110 Lumen/Watt. Housing Shall be made of pressure die cast aluminum body with 40mm height suitable for installation in low heights and polycarbonate diffuser to reduce glare. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and 1 Co-related color temperature (CCT) of 6500K.The luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,EMI/EMC Compliant and Operating voltage range 160-270V .Luminaire and driver shall be separately BIS approved of same make. all types complete with all accessories in the existing opening of false ceiling, giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required | 4 | each | 1,561.49 ₹6,245.96 | 1,500 ₹6,000 Lowest |
| 1.00 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | 14 | each | 170.24 ₹2,383.36 | 165 ₹2,310 Lowest |
| 1.00 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | 70 | each | 52.85 ₹3,699.5 | 25 ₹1,750 Lowest |
| 1.01 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | 14 | each | 2,094.91 ₹29,328.74 Lowest | 2,150 ₹30,100 |
| 1.01 | 90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) | 1 | each | 4,271.15 ₹4,271.15 Lowest | 4,400 ₹4,400 |
| 1.01 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 14 | each | 258.5 ₹3,619 Lowest | 260 ₹3,640 |
| 1.01 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | 1 | each | 1,017.21 ₹1,017.21 Lowest | 1,025 ₹1,025 |
Tender Value
₹2.1 L
EMD Value
₹5,299
Closing Date
31 Jul 2026, 6:00 pmClosed
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
GENERAL-Muzhappilangad School Renovation of Auditorium-Additional Electrification-General Electrical Work
2026_PWD_862152_1
PWD/BLDG/TR/6664/2026_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹5,299
6 Aug 2026
23 Jul 2026
3 Aug 2026
23 Jul 2026
31 Jul 2026
23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | - | - |
| 1.002 | OD77402/2026-2027:Supply, Conveyance installation testing and commissioning of Led Recessed mounted 600*600 mm Luminaire having power consumption not more than 30W and light output not less than 3600 Lumens with System efficacy> 120 Lumen/Watt . Luminaire Housing Shall be made from single piece CRCA body without welding. The Luminaire should be having minimum 50000 Burning hours with CRI ≥80, SDCM<5 and 1 Co-related color temperature (CCT) of 6500K.The luminaire must have 4KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,EMI/EMC Compliant, Operating voltage range 140-270V with High voltage cutoff@325 ± 15V with Auto restart feature. Luminaire and driver shall be separately BIS approved of same make .all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required | - | each | - | - |
| 1.003 | OD77403/2026-2027: Supply, Conveyance installation testing and commissioning of LED Downlight Luminaire having power consumption not more than 18W and light output not less than 2000 Lumens with System efficacy> 110 Lumen/Watt. Housing Shall be made of pressure die cast aluminum body with 40mm height suitable for installation in low heights and polycarbonate diffuser to reduce glare. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and 1 Co-related color temperature (CCT) of 6500K.The luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,EMI/EMC Compliant and Operating voltage range 160-270V .Luminaire and driver shall be separately BIS approved of same make. all types complete with all accessories in the existing opening of false ceiling, giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required | - | each | - | - |
| 1.004 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | - | each | - | - |
| 1.005 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | - | each | - | - |
| 1.006 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | - | each | - | - |
| 1.007 | 90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) | - | each | - | - |
| 1.008 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | - | each | - | - |
| 1.009 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | - | each | - | - |
stage.html
html • 0.02 MB
finance_1458129.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewnit.pdf
Tender Documents • 0.02 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
BOQ_1458129.xls
BOQ • 0.32 MB
MOM.pdf
Tender Documents • 0.20 MB
viewsbd.pdf
Tender Documents • 2.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .