Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.7 L+₹18,064 (3.26%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.8 L+₹23,140 (4.17%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance L3 | |
| 4 | L4₹6.0 L+₹49,714 (8.97%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Non submission of documents in shortfall stage |
Tender Value
Refer Docs
EMD Value
₹10,536
Closing Date
16 Dec 2024, 3:00 pmClosed
EXECUTIVE ENGINEER BIDHANNAGAR ELECTRICAL DIVN
ROOM NO -108 PURTA BHAWAN SALT LAKE KOL 91
Electrical installation and allied works for re constructed Conference Room and Digital studio at 3rd floor of Vidyasagar Bhavan, SITC of Air Conditioning machine
2024_WBPWD_774290_1
WBPWD/EE/BED/e-NIQ-46/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Vidyasagar Bhavan
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,536
ROOM NO -108 PURTA BHAWAN SALT LAKE KOL 91
3 Mar 2025
27 Nov 2024
18 Dec 2024
3 Dec 2024
16 Dec 2024
9 Dec 2024
5 Dec 2024
Amount
Supply, Installation, Testing and Commissioning of Split type AC machine having Cooling Capacity range (6.9 kw - 7.5 kw) with fixed speed Rotary compressor, Refrigerant gas R32 / R410A, BEE star rating - 3, (ISEER range 3.5 to 3.99), Air flow range CFM (780 - 880 or better), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 139 l ( Part - I & Part - II) with all amendments (Make - Mistubishi Electric/Mistubishi Heavy/O-General) as per choice of E.I.C.
Supply and delivery of Cassette Air Conditioner fitted with Rotary Compressor: Cooling capacity nominal (K.Cal/Hr): 5800; Cooling Cap(Min) Guaranteed (K.Cal/Hr): 5500; Min Room Discharge Air Flow (Cu.m/h): 800; R410a / R-32 Gas Without Installation Kit of 12 fts not included. (2TR) Make: Mitsubishi Heavy / O-General / Daikin as per EIC.(NS)
Installation, testing and commissioning Charges for Cassette type A.C machines including making proper arrangements to grout the indoor unit with the ceiling with fass-bolts, Iron Rods & accessories. a)For 2TR Cassette AC
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard 85864 or ANSIB 16.22) incl. 19 mm thick insulation.
5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
Supply & Laying PVC Drain Pipe 25mm dia with 6mm thick nitrile rubber insulation (Make-supreme/Ori-Plast)
S & F 1.1 KV grade, PVC insulated & unsheathed 3 Core 2.5 Sqmm Copper flexible Cable for Indoor to outdoor connection as per direction of EIC.
Supply & fixing for installation of 2 nos outdoor unit of Split type AC Machine by Fabrication of suitable M.S. Structure by 14 mtrs 40x40x80x6mm MS U channel, 37.2 mtrs 25x6mm M.S flat & 12.2 mtrs 25x25x4 mm M.S. angle. The platform & gaurdwall of M.S. structure fixed on outside wall of building by cutting hole & necessary scaffolding arrangement incl. mending good the damages by cement concrete as per direction of EIC & painting the fabrication work with one coat of RO primer & 2 coat of oil paint. Approx weight in kg for M.S. structure = 159.74 kg (For 06 nos Outdoor unit = 159.74 kg X 3 = 479.22 kg i.e. 479.00 kg)
S & F 3mtr of 40mm dia UPVC Pipe as per direction of EIC.
S & F 40mm dia UPVC Elbow as per direction of EIC.
S & F 40mm dia UPVC Socket as per direction of EIC.
S & F 40mm dia UPVC Pipe Clamp as per direction of EIC.
S & F 40mm dia UPVC Bush as per direction of EIC.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for AC installation per storey of building per vertical run.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
GITANJALI ELECTRONICS AND ELECTRICALS (BID ID -5865258)
Lyric International (BID ID -5858704)
Cool Point (BID ID -5861746)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .