| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹53,560Qualified Make: Dr.Trust
Model: Digital Bp Monitor Machine 16 90 2ND FLOOR SUBHASH NAGAR NEW DELHI WEST DELHI DELHI 110027 | WEST DELHI | DELHI | 110027 | Make: Dr.Trust
Model: Digital Bp Monitor Machine | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
8 Jun 2018, 2:00 pmClosed
blood pressure recording units Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 5 Year (s) Blood Pressure Recording Units ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values CONFIGURATION DETAILS Type Of SPHYGMOM ANOMETERS or Blood Pressure recording unit: Digital Digital Conformity to Indian Standrad for SPHYG MOMANOMETERS IS:3390 latest for Mercurial IS:3390 latest for Mercurial Measuring device Automated Automated Type Portable Portable ISI MARKED NA for digital Yes
NA for digital CM/L No and validity date NA - Measurement Method others - Display for Digital BP instrument: LCD(Liquid Crystal Digital) Display - Range: Pressure measurement (mmHg) 0 to 300 - Range:Pulse measurement for digital with accuracy 40 to 200 - 1/5 ± 5%. (per minute) Accuracy:Pressure measurement (mmHg) +/- 3 - Pressure Detection Capacitive Pressure sensor - Inflation Automatic Pressure Application by pump - Deflation and rapid Air Release Automatic Pressure Release Valve - Cuff Range Medium (22-32)cm Medium (22-32)cm Dimensions of the Equipment (mmXmm) 6x4 - Dimensions of the Display screen (mmXmm) 5x3 - Operating Temperature range 0 to 55 degree Celsius - Stroage Temperature range (-10) to 55 degree Celsius - Automatic power off if system is idle for 3 minutes. Yes - Weight (in gram) 250 - Power Power Source: Either Charageble Battery Set Or {220 Volt
50 Hz AC Supply ] Either Charageble Battery Set Or {220 Volt
50 Hz AC Supply ] Type of AA Size chargeable Battery (AA Size) Alkaline Alkaline WARRANTY
CERTIFICATIONS
TEST REPORTS Warranty Period (in Year) 2 2 Availability of Type Test Report covering complete test parameters as per IS3390 latest for Mercurial and IS7652 latest for Aneriod type
from any ILAC/NABL accredited/Central Gov LABFor digital type including Environmental test from any ILAC/NABL accredited/Central Gov LAB Yes - Type test report No and date NA - 2/5 Name and address of the Lab where test Conducted. NA - CE Marking Certificate for B.P. Apparatus Model. Yes - Conformity to OILM- R-16-1 and OILM- R-16-2 for both Non- invasive mechanical sphygmomanometers and Non-invasive automated sphygmomanometers are for guidance and All the Gazette of india related to legal metrology issued time to time
are applicable to the specification as well as to the product. Yes - Others Certificate ie ROHS
WHO
GMP etc. NA - For Digital Sphygmomanometer
Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a) Dry heat test (For 16 hrs at a temp of 55degree C in accordance with IS: 90 00/part-3/section-3/197 7)latest Yes - For Digital Sphygmomanometer Cold test(For 4 hrs at a temp of (-10) degree C in accordance with IS: 9 000/part-2/section-3/19 77latest c) Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temp 55 degree C & 95% RH in accordance with IS: 9000/part-5/sec tion-1/1981)latest Note:- The BP Instrument shall be checked for all the Yes - 3/5 parameters before conditioning After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
BP Instrument shall be functional " * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Deshraj Sharma 175008
Principal
SLBS Govt. Medical College & Hospital
Mandi at Nerchowk. 20 15 EMD Required No ePBG Required No
173083
GEM/2018/B/24667
blood pressure recording units
15 days
Himachal Pradesh; Mandi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| blood pressure recording units Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 5 Year (s) Blood Pressure Recording Units ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values CONFIGURATION DETAILS Type Of SPHYGMOM ANOMETERS or Blood Pressure recording unit: Digital Digital Conformity to Indian Standrad for SPHYG MOMANOMETERS IS:3390 latest for Mercurial IS:3390 latest for Mercurial Measuring device Automated Automated Type Portable Portable ISI MARKED NA for digital Yes | - | - | - |
| NA for digital CM/L No and validity date NA - Measurement Method others - Display for Digital BP instrument: LCD(Liquid Crystal Digital) Display - Range: Pressure measurement (mmHg) 0 to 300 - Range:Pulse measurement for digital with accuracy 40 to 200 - 1/5 ± 5%. (per minute) Accuracy:Pressure measurement (mmHg) +/- 3 - Pressure Detection Capacitive Pressure sensor - Inflation Automatic Pressure Application by pump - Deflation and rapid Air Release Automatic Pressure Release Valve - Cuff Range Medium (22-32)cm Medium (22-32)cm Dimensions of the Equipment (mmXmm) 6x4 - Dimensions of the Display screen (mmXmm) 5x3 - Operating Temperature range 0 to 55 degree Celsius - Stroage Temperature range (-10) to 55 degree Celsius - Automatic power off if system is idle for 3 minutes. Yes - Weight (in gram) 250 - Power Power Source: Either Charageble Battery Set Or {220 Volt | - | - | - |
| 50 Hz AC Supply ] Either Charageble Battery Set Or {220 Volt | - | - | - |
| 50 Hz AC Supply ] Type of AA Size chargeable Battery (AA Size) Alkaline Alkaline WARRANTY | - | - | - |
| CERTIFICATIONS | - | - | - |
| TEST REPORTS Warranty Period (in Year) 2 2 Availability of Type Test Report covering complete test parameters as per IS3390 latest for Mercurial and IS7652 latest for Aneriod type | - | - | - |
| from any ILAC/NABL accredited/Central Gov LABFor digital type including Environmental test from any ILAC/NABL accredited/Central Gov LAB Yes - Type test report No and date NA - 2/5 Name and address of the Lab where test Conducted. NA - CE Marking Certificate for B.P. Apparatus Model. Yes - Conformity to OILM- R-16-1 and OILM- R-16-2 for both Non- invasive mechanical sphygmomanometers and Non-invasive automated sphygmomanometers are for guidance and All the Gazette of india related to legal metrology issued time to time | - | - | - |
| are applicable to the specification as well as to the product. Yes - Others Certificate ie ROHS | - | - | - |
| WHO | - | - | - |
| GMP etc. NA - For Digital Sphygmomanometer | - | - | - |
| Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a) Dry heat test (For 16 hrs at a temp of 55degree C in accordance with IS: 90 00/part-3/section-3/197 7)latest Yes - For Digital Sphygmomanometer Cold test(For 4 hrs at a temp of (-10) degree C in accordance with IS: 9 000/part-2/section-3/19 77latest c) Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temp 55 degree C & 95% RH in accordance with IS: 9000/part-5/sec tion-1/1981)latest Note:- The BP Instrument shall be checked for all the Yes - 3/5 parameters before conditioning After completion of the above environmental tests sequence | - | - | - |
| with a recovery period of 1 to 2 hrs | - | - | - |
| BP Instrument shall be functional " * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Deshraj Sharma 175008 | - | - | - |
| Principal | - | - | - |
| SLBS Govt. Medical College & Hospital | - | - | - |
| Mandi at Nerchowk. 20 15 EMD Required No ePBG Required No | - | - | - |
Exempted
8 Jun 2018
5 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_173083.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .