Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder value | |
| 2 | L2₹8.7 L+₹15,061 (1.75%)Rejected-Finance 24 234 2 NEAR VYDHYUTHI BHAVAN KOTTAPPURAM ROAD PUNKUNNAM THRISSUR KERALA 680002 | THRISSUR | KERALA | 680002 | L2 | Rejected-Finance L2 Bidder |
Tender Value
₹9.3 L
EMD Value
₹23,400
Closing Date
26 Mar 2022, 3:00 pmClosed
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Replacement of Existing Heavy Duty Exhaust Fans with Normal Type Exhaust Fans at Hostel Premises of G V Raja Sports School, Thiruvananthapuram.
2022_SKF_482555_1
32/SKF/CE/2021-22
Open Tender
Electrical Works
Item Rate
60 days
Thiruvananthapuram
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,242
Yes
₹23,400
Yes
24 May 2022
17 Mar 2022
28 Mar 2022
17 Mar 2022
26 Mar 2022
17 Mar 2022
Amount
$Electrical Works
2.3.8 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+12 way, Double door
od333523/2021_2022 : Supply and installation of Single phase 1kVA UPS 72V Pure Sinewave with inbuilt battery for the back of the one hour with THD of output voltage greater 5% of the linear load and IP protection with all accessories
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.7.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire
90.12.41.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
od263735/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)<br>
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
od333517/2021_2022 : Servicing of 400mm wall mounted fan including disconnecting the pull switch nylon cord and re-installation of wall fan without speed control as instructed in Engineer-in charge
1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
od289828/2021_2022 : Dismantling of existing damaged exhaust fans from the top wall at 9 mtr height including connections with all accessories complete as required
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG).
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
od263878/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.<br>2 X 6 sq. mm (19mm)
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
od333700/2021_2022 : Servicing of ATS of 160 KVA generator including replacement of faulty relay disconnecting the supply and reconnecting the same as per the instruction of Engineer in charge
Networking Works For HM Office
1.7.1 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
90.10.1.1 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 1 module moulded plastic box on surface.
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 3 module moulded plastic box on surface.
90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 8 module moulded plastic box on surface.
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.53.2 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable
od333613/2021_2022 : Supply and Installation of 6 KVA UPS Online Double conversion IGBT Inverter with advanced technology and Rectifier with DSP Based System Wide input range from 100-280 V AC with single phase input and single phase output with display panel inbuild LED Display and LED With backup for 60 mins and Battery rack of approved make 3 Years WarrantyDelta Hykon and approved make
od303298/2021_2022 : Supply, Installation, Testing & Commissioning of Single/ Dual Port Faceplate
od303299/2021_2022 : Supply of Router: Wireless Router using the DIR-825/AC device, high-speed wireless network, Simultaneous activity of 2.4GHz band and 5GHz band allows performing a wide range of tasks, 1200 Mbps Speed Frequency: 2.4 GHz, 5 GHz External Antenna
Fire Extinguisher
od296741/2021_2022 : Refilling of Fire Extinguisher 4.0 Kg capacity ABC type by Using Monoammonium phosphate powder ISI,MAP 90
Relaying of Damaged cable and Panel Repair works
90.12.10.5 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 90/75 mm or nearest size
od303317/2021_2022 : Detection of cable fault of UG cable location through suitable techniques including excavation and refilling as per the instruction of Engineer in Charge
90.12.5.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3.5 core 70 sq mm
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG)
High Speed Network for Khelo India Officials
od296771/2021_2022 : Supplying and drawing 4 core Fibre optic cable conforming to relevant standards and giving connections through the surface/ recessed medium class PVC conduit as required
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
od296773/2021_2022 : Supply ,conveyance and erection of 9U rack(D link or equivalent) conforming to relevant standards and giving connections as required
od296774/2021_2022 : Supply,conveyance and installation of Fibre Patch cord(D link or equivalent) conforming to relevant standards and giving connections as required
od296775/2021_2022 : Supply,conveyance,erection and testing of Optical Fiber media converter (D link or equivalent) including adaptor conforming to relevant standards and giving connections as required
od303299/2021_2022 : Supply of Router: Wireless Router using the DIR-825/AC device, high-speed wireless network, Simultaneous activity of 2.4GHz band and 5GHz band allows performing a wide range of tasks, 1200 Mbps Speed Frequency: 2.4 GHz, 5 GHz External Antenna
MERKURY ELECTRICAL CORPORATION
Bidder Name
MERKURY ELECTRICAL CORPORATION
SREEJITH S G
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_693494.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .