Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L1 | Accepted-AOC being lowest bidder | |
| 2 | L2₹21.2 L+₹32,495 (1.56%)Rejected-Finance | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹23.2 L+₹2.3 L (11.2%)Rejected-Finance DOOR NO 44 19 10 RAILWAY NEW COLONY BEHIND SIVALAYAM VISAKHAPATNAM AP 530016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹25.7 L+₹4.8 L (23.0%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹26.2 L+₹5.3 L (25.5%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-Finance not being L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
16 Jan 2025, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF STREET/SECURITY/PERIPHERY/HIGH MAST/GARDEN LIGHTS, POST TOP LANTERNS AND REPAIR/MAINT OF DG SETS AT CTW, INS VISHWAKARMA, B V YARD, SRU, CQAE AND MOV OLD AREA UNDER AGE E/M NO-II OF GE(U-I) VISAKHAPATNAM
2024_MES_663745_3
8674/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer Utility-I
₹82,000
Yes
14 Feb 2025
31 Dec 2024
18 Jan 2025
31 Dec 2024
16 Jan 2025
8 Jan 2025
Amount
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed.
S&F in repair 50 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection / Lamps complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 (using 40mm graded stone aggregate) / bituminous mix as per existing & matching with the surroundings complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete including demolition complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in copings, benching and the like etc. including necessary formwork & demolition of old concrete complete all as specified and directed.
S&F in repair analog time switch 3 module suitable for street light timer panel / DG AMF panel / star delta starter panel complete all as specified and directed. Make :- L&T / Legrand / Siemens / ABB / Schnieder / Havells / HPL
S&F in repair 3 / 4 Pole contactor suitable for street light timer panel / DG AMF panel complete all as specified and directed. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens
Taking down defective street light fitting of any make / type / capacity from top of pole / walls / high mast at a height exceeding 9.0 m but not exc 11.0 m, at any location, for repair work and re-fixing the same after repair work including testing and commissioning complete all as specified and directed. Note:- (i) M&L for Items like ballast, lamp, ignitor, capacitors, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items. However rate quoted shall deemed to include cost of minor spares like nut bolts, circle clips, clamps etc (if reqd) (ii) Necessary T&P like ladders etc required to take the fitting down shall be arranged by the contractor.
S&F in repairs electronic driver of make as per existing, suitable for 120 to 150W street light / flood light / post top lantern complete all as specified and directed. Note:-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
All as per serial Item No. 13.00 above but suitable for 90 to 100 W
All as per serial Item No. 13.00 above but suitable for 70 to 80 W
S&F in repairs surge protection device of capacity 10 KV & make as per existing, suitable for street light / flood light / post top lantern complete all as specified and directed. Note:-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
M&L for dismantling defective LED street / flood light fitting of any make / type and of capacity 120 to 150 W, strip opening the LED panel complete including identifying defective LED diodes, supply and replacement of defective LED diodes, soldering, replacement of pitted control wiring from LED panel to driver etc, testing and commissioning complete all specified and directed by Engineer-in-Charge. Note :-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
All as per serial Item No. 17.00 above but LED street / flood light fitting of capacity 90 to 100 W
All as per serial Item No. 17.00 above but LED street / flood light fitting of capacity 70 to 80 W
S&F in repair LED street light fitting of capacity 60 watt, IP-65 (minimum), integrated type with high efficiency electronic driver, SPD of capaciity 10 KV, pressure die cast aluminium housing with toughened glass cover, internally prewired and including electrically connecting complete all as specified and as directed. Make:- Signify Innovations India Ltd (Formerly Philips) / Havells / Crompton / Bajaj / Jaquar & Co Pvt Ltd Note:- Supply of new GI Pipe bracket if required shall be measured and paid seperately under relevant item.
All as per serial Item No. 20.00 above but LED street light fitting of capacity 90 W
All as per serial Item No. 20.00 above but LED street light fitting of capacity 100 W
All as per serial Item No. 20.00 above but LED street light fitting of capacity 120 W
S&F LED flood light fitting of capacity 120 watt, IP-65 (minimum) with luminous efficacy 100 Lumen/watt (minimum), SPD of capaciity 10 KV, pressure die cast aluminium housing, toughened glass cover, internally prewired and including electrically connecting & all other necessary fixing accessories such as 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers including painting to clamps with two coat of aluminium paint over a coat of red oxide primer & taking down old unserviceable flood light fittings from any position at a height exceeding 7.5 m complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Philips) / Havells / Crompton / Bajaj / Jaquar & Co Pvt Ltd
All as per serial Item No. 24.00 above but LED flood light fitting of capacity 150-170 W
S&F in repair 20 watt LED post top lantern with polycarbonate opal diffuser, pressure die cast aluminium housing, IP-65 (minimum), high efficient constant current electronic driver including electrically connecting complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Philips) / Havells / Crompton / Bajaj / Jaquar & Co Pvt Ltd
M&L for replacement of 35 Sqmm, leaded copper battery cable set of 2 Nos, length not less than 1.5 mtr each, suitable for DG sets, including GM terminals at one end and copper lugs at other end complete all as specified and as directed. Note:- 02 Nos cable of 1.5 m length each shall be measured as one unit.
Supply and topping up of engine oil 15W40 or as per manufacturer’s recommendations suitable for DG sets complete all as specified and as directed. Make: Castrol / Servo / HPCL
Supply and topping up of radiator coolants as per OEM’s recommendations suitable for DG sets complete all as specified and as directed.
S&F in repair 12 V, 90 to 100 AH maintenance free battery complete all as directed . Make : Exide / Amron / Luminous / Nicco / AMCO
All as per Sl Item No. 30.00 but 24 V, 180 AH
M&L for checking complete wiring for AMF panel for DG set engine of capacity 400 to 500 KVA and identifying fault in the safety and control system wiring from AMF panel to engine control gadgets like HWT, LLOP, and shut down valve, dynamo self-starter etc., rectifying fault in the AMF system including replacement of EC-2 Relay, suitable capacity of contactor, burnt control wiring cable with thimbles and ferrules, blown out fuses for proper functioning and testing the DG set complete all as specified and as directed by Engr-in-Charge.
All as per Sl item No. 32.00 above but for DG Set of 15 to 250 KVA capacity
S&F in repair 4 Pole 63 Amps isolator, 415V complete all as specified and as directed. Make :- L&T / Havells / C&S / ABB / Legrand / Indo Asian / HPL
All as per item No. 34.00 but 4 Pole 100 Amps
All as per item No. 34.00 but TPN 63 Amps
All as per item No. 34.00 but TPN 100 Amps
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 95 Sqmm x 3.5 Core, laid in trenches / duct / on pole including taking down existing cable complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
All as per Sl item No. 38.00 but cross sectional area 70 Sqmm x 4 Core
All as per Sl item No. 38.00 but cross sectional area 25 Sqmm x 4 Core
All as per Sl item No. 38.00 but cross sectional area 16 Sqmm x 4 Core
All as per Sl item No. 38.00 but cross sectional area 10 Sqmm x 4 Core
S&F in repair steel tubular swaged poles conforming to IS-2713, complete with cast iron base plate, finial taper plug, bolts, nuts & screws, type 410 SP-31 (9 m long) and including painting with two coat of aluminium paint over a coat of primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and 03 Nos band / strips with white synthetic enamel paint, 30 cm wide each at a distance of 30 cm from top of plinth block and numbering of poles complete all as specified and directed. Note:- Excavation, earth work and PCC work will be measured and paid for separately under respective items. Make of Pole:- Calcutta Poles & Tubes / Skipper Limited / Jindal Steel / National tubing Co / Bombay tube & Store Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
S&F in repair PVC insulated 3 core multistranded sheathed cable with 1.5 Sqmm copper conductor for connection of street / security light etc, complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
S&F in repair three phase, automatic street light control panel with and including astronommical timer switch for automatic switching on / off street light as per set time through programmable switch, 65A, TP power contactor, suitable capacity MCB / MCCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd / Indo Asian
S&F in repair weather proof cable junction box of size not less than 300 mm x 250 mm x 120 mm with terminals, IP 66 (minimum), suitable for outdoor installation,including 01 No 5/6 Amp MCB, 50 Amp rated 3 pole connector, fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers complete all as specified and directed. Make :- Hensel / Sintex Industries Ltd. / C&S electric Ltd. / National / Cape Elect Pvt Ltd.
M&L in repair for bracket suitable for street light made out of GI pipe light grade of 40 mm bore & 1.20 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make of Pipe :- Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L preparation of old painted surface of existing 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the colour code, writing pole details & applying one coat of white wash on pole coping complete all as specified and directed. Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
All as per Sl item No. 46.00 above but 11 m long old steel poles
S&F 2 inches wide reflective tape with high-performance adhesion, water resistant including fixing around the circumference of pole at an approximate height of two meters complete all as specified and directed. Note:- Unit rate quoted shall deemed to include cost for arrangment of all T&P such as ladder etc. reuired.
M&L for alternators warm up of DG Set of 400 to 500 KVA capacity, cleaning the dust with dry blow air, megger the insulation values, measure the load / no load excitation voltages before & after maintenance and recording the values complete all as specified and as directed by Engr-in-Charge.
All as per Sl item No. 49.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 49.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 49.00 above but for DG Set of 15 KVA capacity
M&L for repair and servicing of self starters including replacement / rewinding of armature, carbon brush set with holder, king pin holder, check nut, body screens, clutch plate assembly and solenoid switch etc (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 53.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 53.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 53.00 above but for DG Set of 15 KVA capacity
M&L for De-scaling of radiator of DG set of capacity 400 to 500 KVA by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals (radi wash), components and arresting the leakage in core by brazing / dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, re-fixing the same including testing and painting complete all as specified and directed.
All as per Sl item No. 57.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 57.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 57.00 above but for DG Set of 15 KVA capacity
M&L for preparation of old painted external surfaces of DG set of capacity 400 to 500 KVA including alternator, radiator support channels, connected equipments complete and spray painting with two coats synthetic enamel paint complete all as specified and as directed. Note:-Rusted surfaces of DG Set shall be scraped with sand paper and shall be applied with one coat of zinc chromate primer before application of paint and unit rate quoted against this item shall be considered to include this aspect.
All as per Sl item No. 61.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 61.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 61.00 above but for DG Set of 15 KVA capacity
Cleaning of diesel tank of DG set of capacity 400 to 500 KVA carefully by draining out fuel in the tank including disconnection from fuel system, De-scaling the diesel tank with water pressure and removing the complete sludge deposited, drying the tank, repairing any leakage, cleaning and testing of fuel line up to fuel pump inlet complete all as specified and as directed.
All as per Sl item No. 65.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 65.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 65.00 above but for DG Set of 15 KVA capacity
S&F in repair view glass with beading in canopy (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 69.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 69.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 69.00 above but for DG Set of 15 KVA capacity
M&L for replacement of complete water hose pipe set including clips,nuts, bolts and washers etc (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 73.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 73.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 73.00 above but for DG Set of 15 KVA capacity
M&L for replacement of complete fuel and lub oil hose pipe set with clamp / clip etc (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 77.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 77.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 77.00 above but for DG Set of 15 KVA capacity
M&L for replacement of complete harness wiring (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 81.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 81.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 81.00 above but for DG Set of 15 KVA capacity
M&L for pump & injectors calibration (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 85.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 85.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 85.00 above but for DG Set of 15 KVA capacity
S&F in repair PVC covered iron mesh at fresh air inlet to avoid entry of snakes, lizards etc. all (as per existing) for DG set of capacity 400 to 500 KVA complete all as specified and as directed.
All as per Sl item No. 89.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 89.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 89.00 above but for DG Set of 15 KVA capacity
M&L for carrying out 'B' check for DG set of capacity 400 to 500 KVA after 06 months or 250 hrs running, whichever is earlier as per manufacturer's recommendation including replacement of fuel filters, air filters, oil filters, 'O' rings, engine oil, gasket, coolant etc complete all as per manufacturers instructional manual and all as directed by Engg-in-charge. Note:- Unit rates quoted against this item shall be considered to include cost of fuel filters, air filters, oil filters, 'O' rings, gasket etc.
All as per Sl item No. 93.00 above but for DG Set of 125 KVA capacity
All as per Sl item No. 93.00 above but for DG Set of 30 / 40 KVA capacity
All as per Sl item No. 93.00 above but for DG Set of 15 KVA capacity
S&F in repair AVR suitable for DG sets of capacity 125 KVA to 200 KVA, with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator drop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set initial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max up to 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR, testing & commissioning complete all as specified and as directed by Engr-in-Charge.
All as per Sl item No. 97.00 above but for DG Set of 400 to 500 KVA capacity
Supply and replace automatic battery charger of 12V,0-10 Amps / 0-5 Amps charging rate with auto cut off system complete all as specified. Make : Exide / Amron / Luminous / Nicco / AMCO
F AND M TECHNOLOGIES (BID ID -3216136)
ANJALI ENTERPRISES (BID ID -3215826)
GS ENGINEERS (BID ID -3213029)
VENKATESWARA ENGINEERS AND CONTRACTORS (BID ID -3209413)
GVR ENGINEERING WORKS (BID ID -3215820)
CHAMUNDESWARI ENTERPRISES (BID ID -3215838)
jyothi constructions (BID ID -3210592)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .