Tender Value
₹9.3 L
EMD Value
₹18,700
Closing Date
28 Sept 2026, 5:00 pmDue tomorrow
District Engineer, Zila Parishad, Dhanbad
District Engineer, Zila Parishad, Dhanbad
Renovation, Painting, Electrical work, Deep boring, installation of a submersible pump and necessary equipment at the Netrahin, Mukbadhir School Golf Ground, Dhanbad
2026_ZPDH_119086_1
26/2026-27/DE/ZPDH/DHANBAD/2nd Call
Open Tender
Civil Works
Percentage
90 days
Dhanbad
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,250
Yes
₹18,700
Yes
23 Sept 2026
23 Sept 2026
30 Sept 2026
23 Sept 2026
28 Sept 2026
23 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Deep Boring
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L. | 50 | M | 885.12 | ₹44,256 |
| 2 | (b) From 51.0 M to125.00 M | 75 | M | 924.19 | ₹69,314.25 |
| 3 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
200 mm nominal size dia | 60 | M | 579.59 | ₹34,775.4 |
| 4 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge | 1 | Hours | 794.86 | ₹794.86 |
| 5 | Supplying and commissionig of submersible pump set conforming to IS 8034 and motor conforming to IS 9283 should be suitable for various head and discharge with stainless steel pump soft and polypyenen -do-do- all complete job aas per specification and direction of E/I . 100 MM dia 1.5 HP Pump (sl. 139 M 1055, PG- 124 Part A) | 1 | Each | 19,698.8 | ₹19,698.8 |
| 6 | providing and fixing M.S clamp of required dia to the top ofcasing/housing pipe of tubewell as per IS: 2800(part I) including necessary bolts & nuts of required size complete 200 mm clamp | 1 | Each | 1,598.04 | ₹1,598.04 |
| 7 | Supplying fitting and fizing 3 crore 4 sqmm flat copper submemersible cable Finolex/Hevels make including all taxes royality etc. al complete job as per direction of E/I | 75 | m | 124.3 | ₹9,322.5 |
| 8 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
40mm nominal outer dia pipe | 60 | M | 640.81 | ₹38,448.6 |
| 9 | Supplying fitting of standard make starter pannel board with arrangement of aa necessary protection inlcuding all taxes royalty etc all complete job as per direction of E/I | 1 | Each | 3,305.96 | ₹3,305.96 |
| 10 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40mm nominal outer dia pipe | 20 | m | 580.64 | ₹11,612.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
BOQ_161094.xls
BOQ • 0.32 MB
SBD26.pdf
Tender Documents • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .