Loading…
Loading…
Tender ID
Tender Value
₹2.5 L
EMD Value
₹2,540
Closing Date
13 Feb 2026, 6:00 pmClosed
Deputy Executive Engineer, Electrical (R&B) Sub-Division, Surat
Renovation to Street lights for ITI Mahila building At. Bhimrad Di. Surat.
273227
17 of 2025-26
Open
Electrical Works
Works
Surat
7 documents required · 7 mandatory
₹600
Yes
Executive Engineer, Electrical (R&B) Division, Surat
₹2,540
Yes
5 Feb 2026
5 Feb 2026
5 Feb 2026
13 Feb 2026
5 Feb 2026
Name of work :- Renovation to Street lights for ITI Mahila building At. Bhimrad Di. Surat.
Memorandum showing items of work to be carried out
Item Quantities Item of work Estimated Rates Unit Total
No. estimated but Amount
may be more according to
or less In words estimated
1a 7 Nos Replacing old & u/s by Supplying and erecting 4997.48 Rupees Four Ea
LED street light / Flood light fittings with High Thousand Nine
power White LEDs wattage of 3 Watt and above Hundred
assembled on single MCPCB, efficiency more Ninety Seven
than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with
company mark/name engraved or embossed
to 270 V,Power Factor more than 0.95, THD <
10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %.( fittings required
LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the
ranges shown.) (A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must have
440VAC line supply with over-voltage
protection. (ii) above 48 to 60 Watts Cat-III
1b 20 Nos (A) Street Light (IP-65), Surge protection -4KV 5976.17 Rupees Five Ea
integral and ,Light must have 440VAC line Thousand Nine
supply with over-voltage protection. (iii) Above Hundred
60 to 90 watts Cat-III Seventy Six
2 432 Mtr. Replacing old & u/s by Providing and erecting 126.25 Rupees One Mtr.
XLPE (IS:7098)(I)-88 ISI armoured cable Hundred
multistrand / Solid Aluminium conductor for Twenty Six
1.1 KV. to be laid on wall with necessary And Paise
clamps or in existing trench / pipe of following
size of cables (B) 4 core 6 Sq. mm
3 367 Mtr. Making trench in soft soil of suitable width of 55.55 Rupees Fifty Mtr.
90 cm deep for laying cable or locating the fault Five And Paise
all over the run and back filling the same and Fifty Five Only
making the surface as normal ground.
4 294 Mtr. Providing & laying approved make Double 62.62 Rupees Sixty Mtr.
walled corrugated pipes (DWC) of Two And Paise
polyethylene(conforming to IS 14930 II )with Sixty Two
necessary connecting accessories of same Only
material at required depth in existing trench for
laying of cable. below ground / road surface
for enclosing cable (A)50 mm outer dia
5 27 Nos Replacing old & u/s by Providing and erecting 112.11 Rupees One Ea
Miniature circuit breaker single pole 6A to 25A Hundred
suitable to operate on 240 V A.C. system and Twelve And
having breaking capacity 10 KA to be erected Paise Eleven
in existing box. confirming to IS 8828/1996
with ISI Mark Cat.III
6 4 Nos Replacing old & u/s by Supplying & erecting 476.72 Rupees Four Ea
approved make SMC press moulded composite Hundred
FRP. loop-in, loop-out approx. 2mm thick box Seventy Six
complete with Bakelite connector strip And Paise
5way(3P+N+E),DIN rail for mounting mob &
hinged doors as per requirement having locking
arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole
with cable clamps& earth bolt of following size
of box. (C)150mm x 125mm x 100mm [deep]
7 8 Nos Providing and, fixing heavy duty flange type 38.38 Rupees Thirty Ea
brass cable gland with rubber ring for PVC Eight And
insulated armoured cable complete with out Paise Thirty
going tails, insulating tape etc for following size Eight Only
of cables. (B) 2 to 4 core 6 Sq. mm
8 1 Nos Replacing old & u/s by Providing & erecting 638.32 Rupees Six Ea
415V MCB Four Pole Switch for Lighting Load Hundred
(B curve) having 10KA breaking capacity & Thirty Eight
confirms to IS :8828 in existing box having And Paise
following capacity (b)40 Amp. Cat.III
Rupees Two Lakh(s) Fifty Three Thousand Seven Hundred Eighteen And Paise Eighteen Only
I/We am /are willing to carry out the work at…………% above/below percent (should be written in figures and words) at
the estimated rates mentioned above amount of my/your tender works out as under.
*Estimated Amount *Estimated Amount
put to Tender Rs. 253718.18 put to Tender Rs.
Deduction …………….. % below………………… Add ………… % above Rs. …………….
Less Dismental 10814.82 Less Dismental
Note 1:- An amount of Rs.10814.82 (Rs.Ten Thousand Eight Hundred Fourteen & Eighty Two Paise Only)
towards estimated credit value of dismantled materials shall be recovered from the 1st R.A. Bill of
Note 2:- All work shall be carried out as per public work department hand book and other specifications of Division
Note 3:- Rates quoted include clearance of site (Prior commencement of work and its close) in all respects and hold
good for work under all condition, site, moisture/ weather etc
Note 4:- The Contractor shall exhibit a board as per Government Circular No. BDG/ 3277/ 1657/ N Dated 26/1/1997
S (M.GUJ) with detailed specification and details of work and amount involved at site without any payment
as directed by the Engineer-in-charge.
Signature of Bidder Deputy Executive Engineer
Electrival (R&B) Sub-Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
dismental condition.pdf
FINAL _ SBD (Electrical Work) bOOK LATE.pdf
List of Dismental.pdf
schedule-B.pdf
TENDER NOTICE 17 OF 2025-26.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .