Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.4 LAccepted-AOC 31 GARFA NORTH LAKE ROAD JADAVPUR KOLKATA | KOLKATA | KOLKATA | WEST BENGAL | L1 | Accepted-AOC lowest | |
| 2 | L2₹69.7 L+₹1.4 L (2.01%)Rejected-Finance 18 DHRUBESH CHATTERJEE LANE UTTARPARA HOOGHLY 712258 | UTTARPARA | HOOGHLY | WEST BENGAL | 712258 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹70.1 L+₹1.7 L (2.51%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
29 Nov 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Supply, delivery, laying and connection of cable for high lift pump house power connection and other works under Raghunathpur water supply project under PMD, PHE, Dte.
2024_PHED_766358_12
10 /EE/PMD/PHED OF 2024-2025
Open Tender
MECHANICAL
Item Rate
90 days
Purulia
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.2 L
Yes
17 Feb 2025
5 Nov 2024
2 Dec 2024
5 Nov 2024
29 Nov 2024
5 Nov 2024
Amount
Supply and delivery of 1.1 KV grade XLPE insulated Alumium Armoured cable as per IS: 7098 ( Part -1 )2011 Make: Gloster / Polycab/ Crystal /NICCO/Other approved i) 300 sqmm, 3 core
ii) 240 sqmm, 3.5 core
iii) 185 sqmm, 4 core
iv) 95 sqmm, 4 core
v) 70 sqmm, 3.5 core
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cableand also the trenchwith
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cableand also the trenchwith
Supply delivery and connection of 1.1 KV grade XLPE insulated multistranded Copper unarmoured cable as per IS: 7098 ( Part -1 )2011 Make: Gloster / Polycab/ Crystal /NICCO/Other approved make. i) 150 sqmm
Supply, delivery and installation of MS dismanteling joint PN-2.0 with SS 304 stud.
Supply and delivery of 14 ring current collector box complete with wheather proof enclosure with central pipe complete with slip ring and carbon bush with holder complete with terminal box.
Installation of above current collector after dismanteling of existing damaged current collector, electrical dis-connection and re-connection with all necessery jointing material new one all complete. Testing the newly installed current collector.
Supply& Delivery at site alone front And rear lockable hinged door access type PDB Panel with 1.6 mm thick and load bearing 2 mm CRCA sheet steel enclosed indoor canopy type floor mounted dust & vermin proff equivalent to IP 64 degree protection with detachable gland plateat bottom and necessary lifting hooks with all neoprene gasket cubical type panel board including TPN electrolyte grade , suitable tined copper busber .With Comprising of following feeders. a) Incoming 125 A TPN microprocessor based trip unit for system protection MCCB (Adj over load ) -1 no Standrad breaking capacity. B)Out Going Straigth feeder 63A TPN microprocessor based trip unit for system protection MCCB (Adj over load ) with suitable out going 4 pole terminal -2 Nos , 25A DP MCB-2 nos. The Complete circuit diagram of the panel must be submitted and get it approved from EIC before Delivery(for Garden)
Supply Delivery & fitting fixing in existing VFD mcc panel feeder of 3 phase 7.5 KW,15.4 A Supply voltage 380-480 VAC panel mounted Drive Make PHED Approved Make
Supply& Delivery at site alone front and rear lockable hinged type door, Kioks Box with 1.6 mm thick and load bearing part 2 mm thick CRCA sheet steel enclosed out door canopy type wall mounted dust & vermin proff equivalent to IP 55 degree protection with detachable gland plate at bottom with all neoprene gasket cubical type Kioks Box, including TPN electrolyte grade , suitable tined copper busber terminal rating 300 A for high lift pump cable connection. The Complete Design of the panel must be submitted .
Supply delivery & storage at wtp lakshmanpur of 45 m3/hr @93.6 M head VFD driven vertical multistage centrifugal inline type pump, coupled to 18.5 kw, 2900 rpm, 415V ± 10%, 50 c/s, A/c motor. Pumps shall be suitable for operation between 50 Hz – 12.5 Hz. Make – Grundfos.or its equvelent
Supply delivery & storage at wtp lakshmanpur of 45 m3/hr @38.7 M head VFD driven vertical multistage centrifugal inline type pump, coupled to 7.5 kw, 2900 rpm, 415V ± 10%, 50 c/s, A/c motor. Pumps shall be suitable for operation between 50 Hz – 12.5 Hz. Make – Grundfos.or its equvelent
Installation of above supplied item under sl. No. 9 to 11 at proper places as per requirement at site with supply of all necessery materials to complete the job. All complete in all respect as per direction of EIC
Add GST @ 18%
Add CESS @ 1%
R.N.S.TRADING (BID ID -5760072)
DEY ENTERPRISE (BID ID -5781846)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .