Shri Santosh Kumar Rai IDSE SE CWE NB
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
CLEANING OF UG SUMPS, OH RESERVOIRS AND SERVICE TANKS AND REPAIR/MAINT OF PUMP SETS, PIPE LINE AND CONNECTED WORKS AT INS DRONACHARYA, SMA RAMESWERAM UNDER GE FORT KOCHI.
2024_MES_685199_1
81171
Open Tender
Civil Works
Item Rate
365 days
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹30,000
Yes
7 Feb 2025
22 Nov 2024
21 Dec 2024
22 Nov 2024
19 Dec 2024
6 Dec 2024
Amount
Cleaning of UG Sump 4,50,000 Ltrs capacity by removing/taking out the sediments and cleaning inside, bottom and top of sump using wire brush & wash in side of the sump with clear water and apply two coats of white wash to the wall, bottom and top surfaces, writing date of cleaning and capacity on Sump with synthetic enamel paint complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 2,13,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 1,63,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 1,60,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 1,15,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 1,07,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 76,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 70,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 57,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 43,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 37,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 24,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 18,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Sump of 7,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 1 here-in-before but for UG Static tank of 45,000 Ltrs capacity complete all as specified and as directed.
Cleaning of 4.00 Mtr dia, 6.00 Mtr deep shallow well by removing/taking out the sediments after bailing out water and cleaning inside and bottom of well using wire brush complete and writing date of cleaning on the surfaces of well with synthetic enamel paint complete all as specified and as directed.
Cleaning of RCC Over Head reservoir, 4,50,000 Ltrs capacity, on 18 Mtrs high staging at INS Dronacharya by removing/ taking out the sediments and cleaning inside the reservoir using wire brush & wash in side of the reservoir with clear water and apply two coats of white wash to the inside surfaces of reservoir, writing date of cleaning and capacity on reservoir with synthetic enamel paint on outer surface of reservoir complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 1,22,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 98,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 69,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 52,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 48,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 42,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 29,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 17 here-in-before but for 22,000 Ltrs capacity complete all as specified and as directed.
Note for item Nos 1.00 to 25.00: a) The tank/sump shall be cleaned once in a year. b) For bailing out water, pump set shall be arranged by the contractor. c) Date of cleaning and capacity of sump/tank to be written as per the direction of Engr - in- Charge.
Cleaning inside of PVC Over Head Tank, 5000 Ltrs capacity, by removing/taking out the sediments using brush and wash in side of the tank with clear water complete and writing date of cleaning on OH tank with synthetic enamel paint complete all as specified and as directed.
All as per srl item No 27 here-in-before but for 4,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 27 here-in-before but for 2,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 27 here-in-before but for 1,000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 27 here-in-before but for 500 Ltrs capacity complete all as specified and as directed.
All as per srl item No 27 here-in-before but for 250 Ltrs capacity complete all as specified and as directed.
Cleaning inside of RCC Over Head Tank on multistoried buildings, 12000 Ltrs capacity by removing/taking out the sediments using wire brush & wash in side of the tank with clear water complete and writing date of cleaning on OH tank with synthetic enamel paint complete all as specified and as directed
All as per srl item No 33 here-in-before but for 8000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 33 here-in-before but for 7000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 33 here-in-before but for 5000 Ltrs capacity complete all as specified and as directed.
All as per srl item No 33 here-in-before but for 4500 Ltrs capacity complete all as specified and as directed.
All as per srl item No 33 here-in-before but for 3000 Ltrs capacity complete all as specified and as directed.
Note for item No 27.00 to 38.00: a) The tank shall be cleaned twice in a year b) For bailing out water, pump set shall be arranged by the contractor c) Date of cleaning and capacity of sump/tank to be written as per the direction of Engr - in- Charge. d) The quoted rate shall be considered cleaning of tank at one time
Supply and fix in repair HDPE Water Tank covers suitable for 500 Ltr capacity with locking arrangement complete all as specified and as directed.
Supply and fix in repair HDPE Water Tank covers suitable for 1000 Ltr capacity with locking arrangement complete all as specified and as directed.
Supply and fix in repair HDPE Water Tank covers suitable for 2000 Ltr capacity with locking arrangement complete all as specified and as directed.
Supply and fix in repair HDPE Water Tank covers suitable for 5000 Ltr capacity with locking arrangement complete all as specified and as directed.
M&L dismantling unserviceable electric motor, 2 HP capacity, single phase, opening carefully, taking out old burnout windings, cleaning of slots, motor and stator complete, rewinding of motor with super enameled copper winding wire of same gauge, as per existing pattern with proper insulating material, apply two coats of varnish and heating of windings, reassemble the motor, refixing in the same location, testing and commissioning of motor on full load complete all as specified and as directed.
Dismantling 500 Ltr rotational moulded polythene water storage tanks from multi story buildings removing clear off site after credit for the same is recovered by the dept, complete all as specified and as directed.
Dismantling 1000 Ltr rotational moulded polythene water storage tanks from multi story buildings removing clear off site after credit for the same is recovered by the dept, complete all as specified and as directed.
Dismantling 2000 Ltr rotational moulded polythene water storage tanks from multi story buildings removing clear off site after credit for the same is recovered by the dept, complete all as specified and as directed.
S&F 500 ltr capacity rotational moulded polythene water storage tank cylindrical vertical with closed top, hoisted three layer and connecting to existing water system complete all as specified and as directed.
S&F 1000 ltr capacity rotational moulded polythene water storage tank cylindrical vertical with closed top, hoisted three layer and connecting to existing water system complete all as specified and as directed.
S&F 2000 ltr capacity rotational moulded polythene water storage tank cylindrical vertical with closed top, hoisted three layer and connecting to existing water system complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation etc or not exceeding 10 Sqm on plan & not exceeding 1.5 mtr depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply and fix in repair 15 mm dia ball valves brass high pressure with polythene float and fly nut complete all as specified and as directed.
Supply and fix in repair 20 mm dia ball valves brass high pressure with polythene float and fly nut complete all as specified and as directed.
Supply and fix in repair 25 mm dia ball valves brass high pressure with polythene float and fly nut complete all as specified and as directed.
Supply and fix in repair 40 mm dia ball valves brass high pressure with polythene float and fly nut complete all as specified and as directed.
Taking up or down HDPE pipe of size 100mm dia and connection removing clear of site after credit for the same is recovered by the department complete all as specified and as directed.
Supplying and laying in repair HDPE pipe 110mm dia PE 80 pressure rating 10kg/cm2 incl all fittings/joints laid in trenches complete all as specified and as directed.
Detecting the water leakage from under ground HDPE/PPR pipes up to 110mm bore and rectifying the leakage by taking out existing pipe and arresting the leakage by applying heating machine/mirror and provide suitable fittings/jointing materials if required at site complete including necessay earth work up to 1.5 meter deep complete all as specified and as diretced.
HIGH TECH ENGINEERS AND CO (BID ID -3185484)
3 VOLT ELECTRICALS ENTERPRISES (BID ID -3185309)
GOLDEN EYE BUILDERS (BID ID -3189817)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .