| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹19.1 L+₹31,604 (1.69%)Rejected-Finance 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹19.7 L+₹90,970 (4.85%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹22.0 L+₹3.2 L (17.2%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹24.0 L+₹5.2 L (27.8%)Rejected-Finance MCB Z 5 04939 GURU GOBIND NAGAR BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Being not lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
REPAIR MAINT OF LT ELECTRIC DISTRIBUTION SYSTEM IN DOMESTIC AREA AT AF STATION HALWARA
2020_MES_360413_1
GE/HAL-24/2020-21
Open Tender
Civil Works
Works
365 days
GE (AF) Halwara
MES ENLISETED CONTRACTORS CLASS E CAT b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹50,000
Yes
1 Oct 2020
13 Jul 2020
13 Aug 2020
13 Jul 2020
11 Aug 2020
27 Jul 2020
60 days
Amount
Taking up/down worn out/damaged/unserviceable PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/duct/pole/wall/pipes/roof tops etc. complete including taking out sand cushioning and brick protection etc all as specified and directed. Note:- Excavation and earth work shall be measured and paid separetely.
Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 240Sqmm 3.5 core complete all as specified and directed. Note : Epoxy cable Joints shall be measured and paid separately
All as per Srl item No 2.00 above but of 185 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 150 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 120 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 95 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 70 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 50 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 35 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 25 sqmm 4.00 core.
All as per Srl item No 2.00 above but of 10 sqmm 2 core.
Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 300 Sqmm single core complete all as specified and directed. Note : Epoxy cable Joints shall be measured and paid separately
Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out complete all as specified and directed. Notes : (i) Payment for excavation shall be made for one time in case the new cable is laid in the same trenches .
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.
Brick protection with sub class "B" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed specified .
Sand cushioning in trenches and well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection and complete all as specified and directed. Note: 18 cm punned thickness shall be measured for payment purpose.
40mm bore GI tubing light grade as in cable protection pipe including all fittings as in replacement complete all as directed.
50mm bore GI tubing light grade as in cable protection pipe including all fittings as in replacement complete all as directed.
80mm bore GI tubing light grade as in cable protection pipe including all fittings as in replacement complete all as directed.
Boring under road/path/hard standing to pass the HT / LT UG cables upto 80mm dia pipe using mechanical arrangements complete all as specified and directed.
Heat shrinkable straight through joint for LT XLPE UG cables suitable for cable of size 300 Sqmm 3.5 core aluminium complete all as specified and directed.
Heat shrinkable straight through joint for LT XLPE UG cables suitable for cable of size 185 to 240 Sqmm 3.5 core aluminium complete all as specified and directed.
Heat shrinkable straight through joint for LT XLPE UG cables suitable for cable of size 70 to 150 Sqmm 3.5 core aluminium complete all as specified and directed.
M&L in replacement for feeder pillars box factory made-out door type made out of MS sheet (CRCA) of thickness not less than 3mm of size 75x75x45cm with aluminium bus bar strip 4 Nos of 600 Amps rated suitable for 1100 volt (LT) mounted of LT porcelain insulator front opening door two leaf braced with hinged,mounted on 4 Nos of angle iron 50x50mm duly welded with box and grouted in PCC block of size 30cmx30cmx30cm in concrete 1:2:4 type B-1, Top of box MS sheet duly bent in/slope,tapper with projection of 30mm on all side,weather/vermin proof with high quality of rubber beeding on panel door,cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with two coats of ssmoke grey stove enameled paint over a primer coat including providing MCCB, 4 pole,fixed type 400Amps, 36 KA rating-01 No complete all as directed by Engr-In-Charge.
Cleaning,scrapping,preparing the old painted steel surface of any description and applying two coats of synthetic enamel paint over one coat of red oxide primer to HT/LT panel complete all as specified.
M&L in replacement for earthing complete with GI earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15cm thick and packed layer of charcol dust and common salt filling in alternate layers and electrode connected by galvanised iron strip 32mmx6mm by means of bolts,nuts,check nut and washers connected to test termination point protected by 40mm bore GI pipe light grade and GI pipe light grade 20mm bore for watering and including funnel,wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B1 including exluvation and earth work,disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in electrical plate No.3 of SSR Part-I complete all as specified and directed Note :- (i) The unit rate shall include for GI water pipe,protection pipe wire mesh,funnel,excavation, RCC pit cover, PCC test point, GI strip 32x6mm from top of earth plate upto 5 mtr. (ii) PCC pit shall be providded at least 1.5m away from the earth pit and extra cost of additional length of water pipes and fixing junction,Elbows etc. Shall be deemed to be included in the unit rate. (iii) RCC pit cover shall be percast of RCC 1:2:4, type B-1,80mm thickreinforced with XPM weighing not less than 4kg/Sqm in liue of cast iron cover.
S&F in replacement MCB 63A TPN complete all as specified and directed.
S&F in replacement MCCB 63A 4 pole 25KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 100Amp 4 pole 25KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 160A 4 pole 25KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 200 A 4 pole 25KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 250 A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 315A/320A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 400-A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 630-A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
CHOUDHARY ENTERPRISES
JASSI TRADERS
M/S SANGA SINGH AND CO
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .