Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | ₹15.3 L Quoted ₹16.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹16.5 L+₹53,748 (3.37%)Rejected-Finance JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | ₹16.5 L+₹53,748 (3.37%) | L2 | Rejected-Finance Not Being 1 |
| 3 | L3₹19.6 L+₹3.6 L (22.7%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | ₹19.6 L+₹3.6 L (22.7%) | L3 | Rejected-Finance Not Being 1 |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
24 Sept 2024, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
REPAIR/REPLACEMENT OF LT PANELS, MCCBS, CLEANING OF SUB STATION, PAINTING OF POLES/PANELS INCL ALLIED WORKS UNDER GE (ARMY) TRIVANDRUM
2024_MES_667074_2
8200/E8
Open Tender
Civil Works
Item Rate
270 days
Trivandrum
As per tender documents
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹34,000
Yes
4 Nov 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
24 Sept 2024
7 Sept 2024
31 Aug 2024 - 4 Sept 2024
Amount
Dismantling of unserviceable / broken electric pole of any size and type by disconnecting all connections, demolition of concerted foundation including excavation, earth work as required and removing the same from site complete all as specified and directed.
Dismantling of unserviceable insulators of any size and type from LT overhead lines complete all as specified and directed.
M&L for erection of Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 vertical position complete including painting two coats of bituminous paint thoughout upto the below ground level depth and the remining portion of the exterior shall be painted with anti-fungal weather coat paint complete all as specified and directed.
Stretching/ restringing only ACSR conductor in position on LT overhead lines of any size, type, span length with permissible span sag and binding with pin/ shackle insulator with new aluminium binding wire not less than 2mm dia complete all as specified and directed.
M&L for pin type insulator, porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height and 65 mm dia for 1100 volts grade complete all directed.
M&L for shackle type porcelain vitreous white, brown or green insulator of size 75mm height, 90mm dia (maximum) including galvanised steel fittings straps of section 31mmx3mm, washers, 12mm dia insulator bolts and nuts suitable for working pressure 1100 volts grade complete all as specified and directed.
M&L for loop type insulator, vitreous porcelain, white, brown or green large size, with overall dimensions 90mm x 140mm and clearance of hole 25.5mm complete all as specified and directed.
M&L for preparation old painted surface of cement concrete poles of any size from pole coping to top of pole including struts, cross arms, clamps, etc and painting with two coats of approved colour of aluminium paint on cross-arms over one coat of aluminium red oxide primer and two coats of anti-fungal weather coat paint (apex ultima) on cement poles and numbering of poles as directed with black synthetic enamelled paint complete all as specified and directed.
M&L for LT UG cable XLPE insulated and screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of cross-sectional area 95 Sq.mm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
M&L for LT UG cable XLPE insulated and screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of cross-sectional area 70 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 50 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 35 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 25 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 16 Sqmm, 4 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor of size 2 core x 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including provision of 4mm dia GI suspension wire, one twin core cable flat or circular complete all as specified and directed.
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor of size 2 core x 6 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including provision of 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and directed.
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor of size 2 core x 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including provision of 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and directed.
S&F MCCB 4 pole 400 Amps 415Volt 50Hz breaking capacity 36KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F MCCB 4 pole 250 Amps 415Volt 50Hz breaking capacity 25KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F MCCB 4 pole 200 Amps 415Volt 50Hz breaking capacity 25 KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F MCCB 4 pole 160 Amps 415Volt 50Hz breaking capacity 16KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F MCCB 4 pole 100 Amps 415Volt 50Hz breaking capacity 16KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F MCCB 4 pole 125 Amps 415Volt 50Hz breaking capacity 16KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F MCCB 4 pole 63 Amps 415Volt 50Hz breaking capacity 16KA adjustable type including taking down existing unserviceable complete all as specified and directed.
S&F cable route indicator for LT Cable, cast iron material, 100mm dia, round with 5-6mm thick also paint whole plate with arrow for direction indication and, two hole for mounting (3 mm embossed letter as appropriate) with angle complete all as specified and directed.
M&L for LT Danger notice plate of size 25x15cm, 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size complete all as specified and directed.
S&F synthetic rubber insulated mats 2.50 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety of size 2m x 1 m complete all as specified and directed.
M&L for high density polyethylene pipes (HDPE) of 50 mm bore of pressure rating 6 kgf/cm2 for cable protection laid in trenches complete all as specified and as directed.
M&L for high density polyethylene pipes (HDPE) of 40 mm bore of pressure rating 6 kgf/cm2 for cable protection laid in trenches complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm bore from earth plate to Panel/DBs and water pipe 20mm bore GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm bore GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI strip of size 32x6mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 50mm bore from earth plate to Panel/DBs and water pipe 20mm bore GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm bore GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
Cutting and trimming of tree branches, bushes not exceeding 3 Mtr min clearance around the overhead electric lines/guard wire and removing branches out of defence land complete all as directed. Note: One metre length comprising upto 6 feeder of 2/4 conductors each shall be measured as one unit.
Removing grass and bushes growing at all electric substations and keep all the sub station yards neat and clean complete all as specified and directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean throughout the period of the contract.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32 x 6 mm galvanised iron strip complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 meter but not exceeding 3.00 metre depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, riddled soil including spreading leveling, watering and well ramming in layers not exceeding 25cm using soil obtained from excavation after the pipes/ fittings are laid/ fixed jointed and tested complete all as specified and directed.
Removing excavated soil material from site to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr from the starting point complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 with using 40mm graded stone aggregate as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 with using 20mm graded stone aggregate as in coping of steel tubular poles with necessary form work as required complete all as specified and directed.
S&F in repair to RYB indicator lamp as required in various panel complete all as specified and directed.
S&F in repairs Ammeter/Voltmeter same as per existing, required in various panels complete all as specified and directed.
S L ELECTRICAL WORKS (BID ID -3100124)
JEETH CONSTRUCTION (BID ID -3111613)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .