Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B WING 601 602 DELPHI BUILDING CENTRAL AVENUE HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance B 24 SITE IV GHAZIABAD SAHIBABAD INDUSTRIAL AREA GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Admitted-Finance |
| 4 | Admitted-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Technically not acceptable |
Tender Value
Refer Docs
EMD Value
₹48,500
Closing Date
24 Aug 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SOBHANA V.S.
Corporate Materials, Petrochemical Division, Udyogamandal-683 501
MASSFLOW METER
2020_FACT_570681_1
MM/131/E21748
Open Limited
Miscellaneous Goods
Supply
UDYOGAMANDAL
As per tender
4 documents required · 4 mandatory
₹0
₹48,500
Yes
21 Jan 2021
16 Jul 2020
25 Aug 2020
16 Jul 2020
24 Aug 2020
16 Jul 2020
90 days
Mass Flow meter, Coriolis Type TRANSMITTER: Type: Smart Microprocessor based Remote Field Mounted with Display Display: Required, LCD backlit, alphanumeric Range: User Configurable Flow accuracy (including sensor): +/-0.15% or better Flow Repeatability (including sensor): +/-0.1% or better Output 1): Analog Output, 4-20 mA DC, HART compatible Output 2) : Pulse Output Maximum Load Limit: 700 Ohms or better Power Supply: 110VAC, 50 Hz +/- 10% or Universal (90 to 240 VAC) Display Language: English Display shall have: a) Actual flow rate, user configurable (Units: T/hr; kg/hr), b)Totalizer (non-volatile) with Reset facility (Units:Tonnes; Kilograms), c) Density(Units-g/cc), d)Status / error messages Calibration / Configuration: Through front panel keypad and HART communicator Protection with access code: Required for Calibration/configuration/setup data Memory: Non-volatile EEPROM Self-Diagnostics: Required Cable entry: 1/2 NPTF Junction box/ terminal box material: Die Cast Aluminium or better Enclosure: Weather proof to IP 65 and Ex-proof to Class 1 Div 1 Gr, B or better Mounting Brackets: Required, SS304 for pipe mounting Maximum working temperature: 55 Deg.C Humidity: Up to 95%(RH) SENSOR: Type: Coriolis type, enclosed in a hermetically sealed housing End connection: Flanged, RF Housing Material: SS304 or better Junction box/ terminal box material: Die Cast Aluminium or better Interconnection cables between Sensor and Transmitter: 5 metres (min) required Interchangeability of Sensor and Transmitter: Required (with same/similar models) Instrument details To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification: Required for sensor and transmitter Hydraulic test pressure: 1.5 times maximum working pressure Painting: As per manufacturer’s standard. FLOWMETER,MASS,REMOTE,1 ,300#,LIQUID NH3 Process Conditions : Flowrange : 0-10 Tonnes/Hour End connection : 1 , ANSI 300 Service : Liquid Ammonia Max Pressure : 25 kg/cm2 Density Range : 600-700 kg/m3 Temperature Range : -35 Deg C to 150 Deg.C SENSOR : Flowtube/Wetted Parts Material : SS316L or better FF distance: 586 +/- 3mm [Smaller FF distance is acceptable such that the required spool piece (SS316L) is to be supplied by the vendor to meet the FF distance requirement.]
Mass Flow meter, Coriolis Type TRANSMITTER: Type: Smart Microprocessor based Remote Field Mounted with Display Display: Required, LCD backlit, alphanumeric Range: User Configurable Flow accuracy (including sensor): +/-0.15% or better Flow Repeatability (including sensor): +/-0.1% or better Output 1): Analog Output, 4-20 mA DC, HART compatible Output 2) : Pulse Output Maximum Load Limit: 700 Ohms or better Power Supply: 110VAC, 50 Hz +/- 10% or Universal (90 to 240 VAC) Display Language: English Display shall have: a) Actual flow rate, user configurable (Units: T/hr; kg/hr), b)Totalizer (non-volatile) with Reset facility (Units:Tonnes; Kilograms), c) Density(Units-g/cc), d)Status / error messages Calibration / Configuration: Through front panel keypad and HART communicator Protection with access code: Required for Calibration/configuration/setup data Memory: Non-volatile EEPROM Self-Diagnostics: Required Cable entry: 1/2 NPTF Junction box/ terminal box material: Die Cast Aluminium or better Enclosure: Weather proof to IP 65 and Ex proof to Class 1 Div 1 Gr. B or better Mounting Brackets: Required, SS304 for pipe mounting Maximum working temperature: 55 Deg.C Humidity: Up to 95%(RH) SENSOR: Type: Coriolis type, enclosed in a hermetically sealed housing End connection: Flanged, RF Housing Material: SS304 or better Junction box/ terminal box material: Die Cast Aluminium or better Interconnection cables between Sensor and Transmitter: 5 metres (min) required Interchangeability of Sensor and Transmitter: Required (with same/similar models) Instrument details To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification: Required for sensor and transmitter Hydraulic test pressure: 1.5 times maximum working pressure FLOWMETER,MASS,REMOTE,1 ,300#,RLNG Process Conditions: Flowrange : 0-10 Tonnes/Hour End connection : 1 , ANSI 300 Service : RLNG Max Pressure : 25 kg/cm2 Density (norm.) : 3.72 kg/m3 Temperature Range : -35 Deg C to 150 Deg.C SENSOR : Flowtube/Wetted Parts Material : SS316L or better FF distance: 437+/- 3mm [Smaller FF distance is acceptable such that the required spool piece (SS316L) is to be supplied by the vendor to meet the FF distance requirement.]
Mass Flow meter, Coriolis Type TRANSMITTER: Type: Smart Microprocessor based Remote Field Mounted with Display Display: Required, LCD backlit, alphanumeric Range: User Configurable Flow accuracy (including sensor): +/-0.15% or better Flow Repeatability (including sensor): +/-0.1% or better Output 1): Analog Output, 4-20 mA DC, HART compatible Output 2) : Pulse Output Maximum Load Limit: 700 Ohms or better Power Supply: 110VAC, 50 Hz +/- 10% or Universal (90 to 240 VAC) Display Language: English Display shall have: a) Actual flow rate, user configurable (Units: T/hr; kg/hr), b)Totalizer (non-volatile) with Reset facility (Units:Tonnes; Kilograms), c) Density(Units-g/cc), d)Status / error messages Calibration / Configuration: Through front panel keypad and HART communicator Protection with access code: Required for Calibration/configuration/setup data Memory: Non-volatile EEPROM Self-Diagnostics: Required Cable entry: 1/2 NPTF Junction box/ terminal box material: Die Cast Aluminium or better Enclosure: Weather proof to IP 65 and Ex proof to Class 1 Div 1 Gr. B or better Mounting Brackets: Required, SS304 for pipe mounting Maximum working temperature: 55 Deg.C Humidity: Up to 95%(RH) SENSOR: Type: Coriolis type, enclosed in a hermetically sealed housing End connection: Flanged, RF Housing Material: SS304 or better Junction box/ terminal box material: Die Cast Aluminium or better Interconnection cables between Sensor and Transmitter: 10 metres (min) required Interchangeability of Sensor and Transmitter: Required (with same/similar models) Instrument details To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification: Required for sensor and transmitter Hydraulic test pressure: 1.5 times maximum working pressure Painting: As per manufacturer’s standard. FLOWMETER,MASS,REMOTE,1.5 ,300#,RLNG Process Conditions : Flowrange : 0-20 Tonnes/Hour End connection : 1.5 , ANSI 300 Service : RLNG Max Pressure : 25 kg/cm2 Density (norm.) : 3.72 kg/m3 Temperature Range : -35 Deg C to 150 Deg.C SENSOR : Flowtube/Wetted Parts Material : SS316L or better FF distance: 547+/- 3mm [Smaller FF distance is acceptable such that the required spool piece (SS316L) is to be supplied by the vendor to meet the FF distance requirement.].
Rockwin Flowmeter India Pvt Ltd
Endress plus Hauser India Pvt Ltd
Emerson Process Management (India) Private Limited
Bidder Name
Rockwin Flowmeter India Pvt Ltd
YOKOGAWA INDIA LTD.,
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .