Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹6.1 L+₹3,060 (0.50%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | M/s Ramesh & Company L2 | MAHINDRA WORLD L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for servicing of casette type inverter AC of 1.65/2.7 TR capacity indoor & 4.0 TR outdoor, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location. The rate of wiring, thermistor any type, wire harness assembly, crankcase heater, coil motorised valve, filter etc are required deemed in the quoted rates. | 13 | Each Job | 1,750 ₹22,750 Lowest | 4,000 ₹52,000 |
| 2.00 | S&F in replacement PCB for out door any type/model of 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge. | 24 | Each | 3,200 ₹76,800 Lowest | 7,500 ₹1,80,000 |
| 3.00 | M&L, repairs to existing PCB for outdoor any type/model of 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge. | 3 | Each | 3,200 ₹9,600 Lowest | 4,500 ₹13,500 |
| 4.00 | S&F in replacement PCB for indoor any type/model of casette AC 1.65/2.7 TR capacity of existing make complete all as specified and directed by Engineer-in-charge. | 8 | Each | 3,200 ₹25,600 Lowest | 4,500 ₹36,000 |
| 5.00 | M&L, repairs to existing PCB for indoor any type/ model of casette AC 1.65/2.7 TR capacity by changing parts /soldering etc complete all as specified and directed by Engineer-in-charge. | 8 | Each | 3,000 ₹24,000 Lowest | 3,000 ₹24,000 Lowest |
| 6.00 | S&F in replacement Adaptor complete all specified and directed by Engineer-in-charge. | 4 | Each | 2,560 ₹10,240 | 750 ₹3,000 Lowest |
| 7.00 | M&L recharge top up gas refrigerant R-410A in casette type of cap 1.65/2.7 TR complete all as specified and directed by Engineer-in-charge. | 80 | Kg | 810 ₹64,800 Lowest | 960 ₹76,800 |
| 8.00 | S&F in replacement fan blower of casette type 1.65/2.70 TR capacity of existing make complete all as specified and directed by Engineer-in-charge. | 4 | Each | 5,600 ₹22,400 | 2,000 ₹8,000 Lowest |
| 9.00 | S&F in replacement fan motor for indoor of casette type 1.65/2.70 TR capacity of existing make complete all as specified and directed by Engineer-in-charge. | 6 | Each | 5,600 ₹33,600 | 1,000 ₹6,000 Lowest |
| 10.00 | S&F in replacement fan motor for oudoor of casette type AC 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge. | 8 | Each | 7,500 ₹60,000 | 1,000 ₹8,000 Lowest |
Tender Value
₹6.3 L
EMD Value
₹12,660
Closing Date
3 Nov 2025, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LABORATORY JODHPUR
REPAIR AND MAINT OF CASSETTE AC INSTALLED IN NTC AT DEFENCE LAB JODHPUR
2025_MES_735739_1
8698/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹12,660
Yes
24 Feb 2026
17 Oct 2025
6 Nov 2025
17 Oct 2025
3 Nov 2025
27 Oct 2025
18 Oct 2025 - 25 Oct 2025
Amount
M&L for servicing of casette type inverter AC of 1.65/2.7 TR capacity indoor & 4.0 TR outdoor, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location. The rate of wiring, thermistor any type, wire harness assembly, crankcase heater, coil motorised valve, filter etc are required deemed in the quoted rates.
S&F in replacement PCB for out door any type/model of 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L, repairs to existing PCB for outdoor any type/model of 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement PCB for indoor any type/model of casette AC 1.65/2.7 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L, repairs to existing PCB for indoor any type/ model of casette AC 1.65/2.7 TR capacity by changing parts /soldering etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement Adaptor complete all specified and directed by Engineer-in-charge.
M&L recharge top up gas refrigerant R-410A in casette type of cap 1.65/2.7 TR complete all as specified and directed by Engineer-in-charge.
S&F in replacement fan blower of casette type 1.65/2.70 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement fan motor for indoor of casette type 1.65/2.70 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement fan motor for oudoor of casette type AC 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L finding out leakage with the pressure testing of the condensor/cooling unit/ compressor including nitrogen flushing if required and dismantling the same for recharging and stop leakage by brizing/soldering including charging the R-410A gas to required level and testing the AC for the entire satisfaction of Engineer-in-Charge.
S&F in replacement of compressor 4.0 TR Capacity casette type Air conditioner as per existing make including leakage testing etc complete all as specified and directed by Engineer-in-charge. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transporation, fittings, etc. complete with necessary guarntee period including oiling and R-410A gas charging, testing etc complete.
S&F in replacement of blower and bush of casette type capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement of fan blade of casette type capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L, repairs to existing blower moter of any capacity by re-winding / changing parts /soldering etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement blower moter of any capacity complete all as specified and directed by Engineer-in-charge.
Supply and fix capacitor of any type suitable for outdoor/ indoor unit as per sample and make for existing all as directed.
Supply and fix in replacement of old unsv remote control suitable for cassette type AC as per sample and make for existing all as directed.
M&L, for pipe insulation suitable for outdoor/ indoor complete all as specified and directed by Engineer-in-charge.
S&F contractor suitable for outdoor unit complete as per sample and make for existing all as directed by Engineer-in-charge.
S&F filter drain pump for indoor unit cassete type complete as per sample and make for existing all as directed by Engineer-in-charge.
S& fixing copper pipe/ refrigerent tube as epr existing size as required complete all as directed by Engineer-in-charge.
S&F three core copper cable 6 sqmm all as specified and as directed by Engr-in-Charge
M/s Ramesh & Company (BID ID -3465815)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
PS.pdf
Tender Documents • 1.06 MB
BOQ_823868.xls
BOQ • 1.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .