Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74,010.53Accepted-AOC | L1 | Accepted-AOC Accepted Vide Resolution No.1(3) dtd.09/06/2026 of MOONNILAVU GP | |
| 2 | L2₹77,785.07+₹3,774.54 (5.10%)Rejected-AOC | L2 | Rejected-AOC Higher rate and hence not admitted |
Tender Value
₹74,011
EMD Value
₹1,850
Closing Date
28 May 2026, 3:00 pmClosed
ASSISTANT ENGINEER
ASSISTANT ENGINEER MOONNILAVU GP
Chillichi kadavu Kuzhalkinar maintenance-General Electrical Work
2026_LSGD_851606_7
02/2026/AE/LID EW/MNLV/2026-27
Open Tender
Civil Works - Water Works
Percentage
MOONNILAVU GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹1,850
Yes
23 Jul 2026
19 May 2026
29 May 2026
19 May 2026
28 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification Work | |||||
| 1.001 | OD20917/2026-2027:Supply and installation of dust and Vermin proof wall mounding meter box SINTEX make GSMB 4537 or equilent make with base plate suitable to fix 3 phase energy meter and 3 nos 63A fuse and Nuetral link. | - | each | 5,658 | - |
| 1.002 | OD20921/2026-2027:Supply and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base | - | each | 246.18 | - |
| 1.003 | OD20922/2026-2027:Supply and fixing 63, HRC Fuse Base with HRC Fuse link | - | each | 246.18 | - |
| 1.004 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | - | metre | 66.57 | - |
| 1.005 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | - | set | 8,603.47 | - |
| 1.006 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm | - | metre | 143.9 | - |
| 1.007 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm | - | metre | 463.09 | - |
| 1.008 | 2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door | - | each | 3,616.96 | - |
| 1.009 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
40 amps | - | each | 3,670.37 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1439211.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.37 MB
AFFIDAVIT.pdf
Tender Documents • 0.28 MB
FORM.pdf
Tender Documents • 0.29 MB
BOQ_1439211.xls
BOQ • 0.32 MB
FEE.pdf
Tender Documents • 0.47 MB
PA.pdf
Tender Documents • 0.30 MB
EPAYMENT.pdf
Tender Documents • 0.28 MB
FORMOFINTEGRITY.pdf
Tender Documents • 0.23 MB
SBD.pdf
Tender Documents • 1.04 MB
CORI.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .