Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.2 CrAccepted-AOC | ₹9.2 Cr | 1 | Accepted-AOC L1 ACCEPTED |
| 2 | 2₹9.3 Cr+₹14.7 L (1.60%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹9.3 Cr+₹14.7 L (1.60%) | 2 | Rejected-AOC L2 |
| 3 | 3₹10.7 Cr+₹1.6 Cr (17.3%)Rejected-AOC | ₹10.7 Cr+₹1.6 Cr (17.3%) | 3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | SWATHY CONSTRUCTIONS L3 | Shaijal TM L2 | BIJU P DANIEL AND CO L1 |
|---|---|---|---|---|---|---|
| 1.00Land Development Works | ||||||
| 1.01 | 2.32. Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. | 1,995.14 | sqm | 10 ₹19,951.38 | 10 ₹19,951.38 | 7.5 ₹14,963.53 Lowest |
| 1.02 | 2.31. Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 200 | sqm | 15 ₹3,000 | 20 ₹4,000 | 13 ₹2,600 Lowest |
| 2.00Building Earthwork Excavation | ||||||
| 2.01 | 2.8.1. Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil | 561.92 | cum | 300 ₹1,68,576.3 | 270 ₹1,51,718.67 Lowest | 280 ₹1,57,337.88 |
| 2.02 | 2.26.1. Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 45.09 | cum | 100 ₹4,508.9 Lowest | 100 ₹4,508.9 Lowest | 103 ₹4,644.17 |
| 2.03 | 2.6.1. Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil | 80.49 | cum | 215 ₹17,304.92 | 200 ₹16,097.6 | 195 ₹15,695.16 Lowest |
| 3.00Building concrete works | ||||||
| 3.01 | 5.9.1. Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete | 97.34 | sqm | 330 ₹32,121.54 | 310 ₹30,174.78 Lowest | 315 ₹30,661.47 |
| 3.02 | 5.9.2. Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 106.98 | sqm | 720 ₹77,028.48 | 715 ₹76,493.56 | 670 ₹71,679.28 Lowest |
Tender Value
₹9.9 Cr
EMD Value
₹11,800
Closing Date
17 Jul 2025, 11:00 amClosed
Chief Engineer KSHB
Chief Engineer KSHB
Construction of Working Womens Officers Quarters at Gandhinagar Kottayam Civil Electrical and MEP Works Package I
2025_KSHB_772228_1
2025_CE _KSHB_06(W)
Open Tender
Civil Works - Others
Item Rate
Gandhinagar Kottayam
Refer SBD
2 documents required · 2 mandatory
₹11,800
₹11,800
Office of the Chief Engineer KSHB
23 Sept 2025
27 Jun 2025
18 Jul 2025
27 Jun 2025
17 Jul 2025
27 Jun 2025
8 Jul 2025
Amount
Land Development Works
2.32. Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.31. Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
Building Earthwork Excavation
2.8.1. Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
2.26.1. Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.6.1. Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
Building concrete works
5.9.1. Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.9.2. Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.5. Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6. Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
od25079/2025_2026. Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work upto plinth level
od25098/2025_2026. Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work upto plinth level
od25110/2025_2026. Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work above plinth level upto floor V level
od25111/2025_2026. Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.All work above plinth level upto floor V level
4.1.8. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
14.90.1. Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25 degreee, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal degree and transverse direction at 23degree as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150degree. Cold flexibility shall be upto -2 degree when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
5.9.3. Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.6. Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7. Centering and shuttering including strutting, etc. and removal of form for: Stairs, (excluding landings ) except spiral - staircases)
5.9.15. Centering and shuttering including strutting, etc. and removal of form for: Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
5.9.16.1. Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and walls.Under 20 cm wide
5.9.19. Centering and shuttering including strutting, etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges
5.22A.6. Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo - Mechanically Treated bars of grade Fe-500D or more
od24044/2025_2026. Providing and fixing SS Fan clamp of 10 mm dia or nearest avialble size SS bar bent to shape with hooked ends in RCC slab , beams during laying including painting the exposed portion of loop and protecting the same during concreting , all as per direction
filling
2.25. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1. Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
2.34.1. Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lindane emulsifiable concentrate of 20%
2.35.3.1. Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
solid block
50.6.1.5. Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.6. Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
50.6.3.2. Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
50.6.1.8. Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
50.6.1.9. Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Building finishing
13.1.1. 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
5.23. Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
5.30.Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.
13.43.1. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.46.1. Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.60.1. Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
13.80. Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
50.9.12.1. Providing and fixing Thomson Multi wood board or equivalent make, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately) as per the direction of site Engineer-in-charge.
9.90.2. Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Size 50 mm
9.114.1. Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type
9.115. providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer -in-charge.
9.116. Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section ( The payment of C or E channel shall be made separately
9.165.2. Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100mm
51.13.21.1. Water proof plastering with Cement Mortar 1:4 (1 cement : 4 fine sand) 12mm thick plaster finished with a floating coat of neat cement mixed with water proofing compound of approved make @ 2kg/m2 of mix floated hard and troweled smooth including all labour, material, conveyance charges etc complete.
22.5. Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
doors and windows
9.48.2. Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13.61.1. Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
9.53. Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
50.9.15.1. Supplying and fixing 200 mm Aluminium aldrop
od26315/2025_2026 Supplying and fixing of Anchor Bolt ( m16 length 100 mm)
od245132/2024_2025. Supplying and fixing 200mm SS hooks and eyes for all floors
9.147B.1. 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
9.147D.1. Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
9.7.7.2. Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 5.5mm thick glass pane
9.147D.4. Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
9.147E.1. Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).<br> Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.)
9.75.1. Providing and fixing bright finished door latch with necessary screws etc. complete: 300x16x5 mm
9.103. Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.
9.121. Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.1. Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
9.147D.2. Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
9.147D.3. Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
9.153. Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete.
9.84. Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.1.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
9.5.1.1. Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood. Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters
9.70.1. Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete: 125x64x1.90 mm
10.6.1. Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7. Providing and fixing ball bearing for rolling shutters.
10.9. Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
floor and wall tile
11.41.2. Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completeSize of Tile 600 x 600 mm..
11.47.2. Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
od25226/2025_2026. Providing and laying rectified Anti skid Ceramic floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with epoxy grout and matching pigments etc., complete.
od25233/2025_2026. Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with epoxy grout@1 kg per sqm, including pointing with epoxy grout
11.55.1. Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
8.2.2.2. Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm
8.5. Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
8.9.1.2. Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. Granite of any colour and shade
handrail
10.26.1. Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. M.S. tube
10.28. Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
13.61.1. Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Plumbing & sanitory fixing
17.2.1. Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
17.7.2.Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
17.32.1. Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia
od26317/2025_2026Providing and fixing C.P adjustable type good quality shower rose with shower arm (18") including cost of conveyance of all materials to site, labour charges etc. All complet
od245133/2024_2025. providing and fixing 110mm PVC four way floor trap gully including stainless steel grating
50.17.1.1.Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.3.Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.5.Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.18.9.8.1.Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1.Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.14.1.Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
50.18.9.18.1.Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.19.1.Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing ISI marked uPVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes all fittings/ specials and jointing of pipes with one step solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
od26586/2025_2026 Providing and fixing ISI marked uPVC pipes including all fittings/ specials and jointing of pipes with one step solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
od26627/2025_2026 Providing and fixing ISI marked uPVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes all fittings/ specials and jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - Exposed on wall
50.18.9.21.4. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
50.18.9.21.5. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee
50.18.9.21.6. Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee
50.18.9.21.7. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.9.22.4. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
50.18.9.22.6. Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
50.18.9.22.8. Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
18.77. Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
18.50.1. Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
18.52.1. Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 8931 15 mm nominal bore
18.19.2.1. Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal bore Horizontal
18.19.2.2. Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal bore Vertical
17.10.2.3. Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink without drain board 470x420 mm bowl depth 178 mm
18.51.1. Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
19.7.1.1. Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.7.2.1. Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg): With common burnt clay F.P.S ( non modular) bricks of class designation 7.5
19.7.3.1. Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg) With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5
18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.8.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes
18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm nominal outer dia pipes
18.8.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm nominal outer dia pipes
od26339/2025_2026Providing and fixing ISI marked uPVC pipes includings jointing of pipes with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
od26340/2025_2026Providing and fixing ISI marked uPVC pipes includings fittings and jointing of pipes with one step uPVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
od26341/2025_2026 Providing and fixing ISI marked uPVC pipes including fittings and jointing of pipes with one step uPVC solvent cement, trenching, refilling & testing of joints as per direction of Engineer in Charge.20 mm dia 12 Kgf/cm2
od26342/2025_2026 Providing and fixing ISI marked uPVC pipes, fittings including fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
26343/2025_2026 Proviodding and fixing ISI marked uPVC pipes, fittings including fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
od26344/2025_2026 Providing and fixing ISI marked uPVC pipes, fittings including fittings fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10 Kgf/cm2- Internal work- exposed on wall
od26345/2025_2026Providing and fixing ISI marked uPVC pipes, fittings including fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2
od26346/2025_2026Providing and fixing ISI marked uPVC pipes, fittings including fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2
od26347/2025_2026Providing and fixing ISI marked uPVC pipes, fittings including fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 12 Kgf/ cm2
truss work
50.10.1. Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.61.1. Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
od26225/2025_2026Supply and laying 4 mm thick asphalt shingles over 6 mm thick cement board including labour cost
compound wall & Gate and drain
2.8.1. Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
2.25. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1. Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.2.2. Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.2. 12 mm cement plaster of mix: 1:6 (1 cement : 6 fine sand).
13.46.1. Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
5.22.6. Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
od25079/2025_2026Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work upto plinth level
13.61.1.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
10.25.2. Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
landscape
55.22. Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete.
4.2.A.2. Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. Grading-IV - For lower sub base - Mix in Place Method
11.3. Making lawns including plouhing and breaking of cold, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm
Road Work
3.6. Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
4.1.B.2. Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. Grading-VI - For sub base cum drainage layer - Mix in Place Method
4.12. Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a. Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.a.Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.3.2.a. Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder (VG 30), transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. For Grading II - (19 mm nominal size)
5.6.2.a. Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)
10.2. Maintenance of Earthen Shoulder (filling with fresh soil) Making up loss of material/ irregularities on shoulder to the design level by adding fresh approved soil and compacting it with appropriate equipment.
12.4. Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
UG Sump & Septic Tank
50.2.3.1. Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
50.18.8.8.1. Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.10.1. Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
2.6.1. Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
2.25. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.26.1. Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil
4.1.8. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.2. Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3. Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
5.9.16.1. Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide
5.22.6. Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
od25098/2025_2026. Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work upto plinth level
19.18.3. Supplying and fixing C.I with out frame for manholes: 560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg
19.7.1.1. Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.7.2.1. Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg): With common burnt clay F.P.S ( non modular) bricks of class designation 7.5
13.9.1. Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
13.21. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
22.1.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-charge and consisting of :i ) Ist layer of 22 mm to 25mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the leveling course ( leveling course to be paid separately). Joints separately) joints sealed and grouted with cement slurry mixed with water proofing compound. II) 2nd layer of 25 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate if 10 mm to 12 mm nominal size spreading @ 8 cudm/ sqm thoroughly embedded in the 2nd layer Using rough kota stone
22.2.1Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS : 2645 in recommended proportion with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-Charge: Using rough Kota stone
BORE WELL
od26300/2025_2026Boring / drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including hire & running charges of all equipments, tools plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 100 metre depth below ground level. All types of soil 150 mm dia
23.8. Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine /medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in- charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge. 150 mm nominal size dia
WIRING
1.10.1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
1.10.2. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
1.10.3. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
od23118/2025_2026. Wiring for twin control light point / fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthling the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.25. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.31. Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.33. Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.14.1. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.14.7. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
1.17.3. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm
1.17.6. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm
1.17.9. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 9 x 1.5 sq. mm
1.17.12. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
1.17.15. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 2.5 sq. mm
1.14.5. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
90.12.1.43. Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4 core 35 sq mm
90.12.7.43. Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 35 sq mm with factory made clamp
90.12.7.4. Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 16 sq mm with factory made clamp
90.12.7.31. Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 95 sq mm
90.12.7.41. Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp
9.1.3. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 16 sq. mm (22mm)
9.1.24. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 95 sq. mm (45mm)
9.1.33. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
9.1.35. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 35 sq. mm (32mm)
90.12.7.30 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 70 sq mm
90.12.7.32 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 120 sq mm
9.1.23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 70 sq. mm (38mm)
9.1.25 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
LIGHTS
od23100/2025_2026. Supply Conveyance, installation, testing and commissioning of 30W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The driver compartment should be separately accessible for maintenance
od23102/2025_2026. Supply, conveyance, installation, testing, and commissioning of the Post top/gate light with aluminum die-cast black powder-coated body with PC textured sheet Diffuser for 15-20 w Wall mounting including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
od23105/2025_2026. Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium powder coated black shade body, heat resistant polycarbonate OPAL/ prismatic glass cover suitable for 9W LED to wall/ceiling, including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
od23107/2025_2026. Supply conveyance, installation, testing and commissioning the light fittings of following types made with White powder coated/pre coated finish, CRCA channel for single for 1200 mm 18W/20W LED tube having IP20 , 6000 K, 20W - 2000 lumens, Aluminum housing with PC diffuser, THD<20%, Surge - 2kV, CRI-80, 50000 burning hours, single sided connection,. Multistage Isolated Constant Current Operated driver with range 110-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm 1X(18/20W) Aluminum housing with PC diffuser LED Tube(LTT8) with box type fixture
od23130/2025_2026. Supply, conveyance, installation, testing and commissioning of 10W ( 2 feet),600+/-100 mm, high-efficiency LED batten surface/wall mounted LED batten, Luminaire lumen ≥ 903 lumens (90 lm/W), IP20, Specially designed Co-extruded channel in thermally conductive material with plastic and HET diffuser. CRI 80, CCT - 6500K,50000 burning hours as per L70 Criteria, In-built electronic driver duly wired up to terminal block, Temperature range-0 to 50DegC, Driver efficiency-85%, Power factor-0.9THD-20%, Surge protection 2kV, Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level-60V DC as per IEC standard with all accessories and lamps etc. Directly on the wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
od23131/2025_2026. Supply, conveyance, installation, testing and commissioning of Slim panel Surface mounted 300x300 mm down lighter with all accessories, housing made up of die-cast aluminium for better heat management. High Transmittivity Diffuser for better light output and uniform light distribution without glare. Driver and accessories are pre-wired for easy installation and long service. CRI-70, Colour temperature-6000K, IP20, Ambient temp-0 to 45 °C, Driver efficiency-85%, THD<20%, Powerfactor>0.95, Surge protection 2KV, Multistage Isolated Constant Current operated driver with range 150- 270V AC and Safety Extra Low Voltage Safe level-60V DC as per IEC standard. Square Slim surface mounted, Wattage ≤ 24W, with luminaire lumen ≥ 2000 lm and giving connection with 3 core round flex wire, etc., complete.
FAN,EXHAUST FAN
90.5.1.3. Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required. Ding dong bell
od23120/2025_2026. Supplying and fixing following modular buzzer on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Buzzer
od23122/2025_2026. Supply, conveyance, installation, testing and commissioning the following sizes of Exhaust fan in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS - heavy duty 450 mm ( 18 ”) minimum Rated speed 1300rpm with with aire delivery- 5500m3/hr 4 nos of MS powder coated blade bolted to aluminium die cast spider balanced rated rpm frame is made from deep drawn steel the four arm fitted with rubber mounting for silent operation
od23123/2025_2026. Supply, conveyance, installation, testing and commissioning the following sizes of Exhaust fan in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS -225 mm ( 9”) minimum Rated speed 1300rpm with with aire delivery 3 nos of MS powder coated blade and frame
od23124/2025_2026. Supply, conveyance, installation, testing and commissioning the following sizes of WALL fans, fixing with necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS 400mm sweep with minimum air delivery 85 m3/hr with plastic / aluminium blades rotary switch with pull cord and full wall mounting
od23125/2025_2026. Supply, conveyance, installation, testing and commissioning the following sizes of WALL fans fixing with necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS 450mm sweep with minimum air delivery 230 m3/hr ,Aluminium die cast with 3 nos of blades full wall mounting
od23126/2025_2026. Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
PVC CONDUITS
90.1.1.1. Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required. 20 mm
90.1.1.2. Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required. 25 mm
90.1.1.3. Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required. 32 mm
1.21.1. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
1.21.2. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
1.21.3. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
1.21.5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 50 mm
DB, SWITCH,SOCKET,BOX
1.24.1. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
1.24.3. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
1.24.4. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
1.24.5. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
1.24.6. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
90.6.9.2. Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit 2 pair
1.24.7. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
1.27.1. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
1.27.2. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
90.10.3.15. Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator
90.10.3.32. Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A 3 pin plug top with indicator
90.10.3.33. Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A 3pin Shuttered socket
1.27.5. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)
2.18. Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.20. Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
90.11.1.18. Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.2.2. Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 125 Amp,16 KA,TPMCCB
90.11.1.11. Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.15. Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.4.3. Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
2.10.1. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.10.5. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
2.12.1. Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.14.2. Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.13.2. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.15.3. Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.13.3. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps
od23127/2025_2026. Supplying and fixing the following rating, four poles, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100mA in the existing MCB DB complete with connections, testing, and commissioning, etc. as required.100 amps
od24640/2025_2026. Supplying and fixing of double pole, (single phase and neutral), 240 V, 30 amps EB rating 3A Gen rating ACCL(Automatic Changeover Current Limiter) having indications for EB, DG and overload and reset button in the existing MCB DB complete with connections, testing and commissioning, etc. as required.
2.3.4. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 16 way, Double door
NAPKIN VENDING ,DISPOSAL MACHINE ,TOILET REFRESHNER, WATER HEATER
od23096/2025_2026. Supply and installation of hygiene auto clean dispenser for toilet
od23109/2025_2026. Supply, installation, Testing and commissioning of Sanitary Napkin Incinerator/Destroyer with the following specification: Power Source- Electrical, Waste Type- Sanitary Napkin, Capacity -10 Napkins/cycle, Energy Consumption – Electric, Burning time 20 minutes Operation -timer cut off 2-inch flexible hose exhaust heating base ss304, freely operating hingged front loading doorb vent on top and bottom operational voltage 230 v as per the direction of Engineer in charge
od23111/2025_2026. Supply, installation, Testing and commissioning of Sanitary Napkin vending machine with the following specification operation – Machine Manual, usage/application –all public and private places, Brand –Approved make and model, Power-Electric, Machine operating type manual coin acceptor accepts only one type of coin in single slot ,dispenses one napkin at a time , wall mounted type,with inspection window storage capacity approximate 20-30 napkins as per the direction of Engineer in charge
od23112/2025_2026. supply Conveyance, installation, testing and commissioning of a 25 L water heater with a 2000 W - 3000 W power range 4/ 5-star rated vertical water heater having a minimum 5-year warranty, with indications Bicolor LED Indicator for power & heating which is easly connected to 16 A socket with over thermal cut off thich steel tank with a coting having high resistance against correction water pressur 7 mpa or more and all BIS IS standards
od23114/2025_2026. supply Conveyance, installation, testing and commissioning of a 15 L water heater with a 2000 W - 3000 W power range 4/ 5-star rated vertical water heater having a minimum 5-year warranty, with indications Bicolor LED Indicator for power & heating which is easly connected to 16 A socket with over thermal cut off thich steel tank with a coting having high resistance against correction water pressur 7 mpa or more and all BIS IS standards
od23116/2025_2026. supply Conveyance, installation, testing and commissioning of a 5 L water heater with a 2000 W - 3000 W power range 5-star rated vertical water heater having a minimum 5-year warranty, with indications Bicolor LED Indicator for power & heating which is easly connected to 16 A socket with over thermal cut off and all BIS IS standards
EARTHING
5.4. Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.8. Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.9.Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.12. Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
5.15. Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.14. Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.16.1.2. Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG)
90.16.1.3. Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
MASTER CONTROL SWITCH
90.10.3.15. Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator
WATER PUMP
od23104/2025_2026 Suction & delivery fittings such as foot valve, delivery side NRV, 2no wheel valve and and giving connection
od26578/2025_2026 Supply, installation, Testing and commissioning of 1.5 HP 15 to 20 Stage Stainless steel Submersible pump set standard make including required 2.5 sq.mm flat cable ,12 mm Garware marine rope , good quality1” 6 kg HDPE Pipe, Digital Multi Colour DOL starter/Controller and required all other materials Including hire charges for tools and plants required for the works. Final measurement will be taken based on the data for preparing for estimate as per the direction of Engineer in charge.
od26579/2025_2026 Supply, Installation, Testing and Commissioning 2 nos, horizontal centrifugal pumps (submersible pump) set, having CI Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 3 lps @ 25mtr head, Head range 15 to 35 mtrs, ''F'' class Insulation, with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller with necessry cable for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation. (For Domestic Water from sump to OHT)
MAIN PANEL
od23215/2025_2026. METER PANEL Supply installation testing and commissioning of 125A,LT wall mounted type, dust and vermin proof, free standing / wall mounting cubical type construction, made out 16SWG CRCA sheet painted with approved colour and of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, complete with Aluminium/copper bus bars as below, inter-connection with copper conductor wires / aluminium strips, neutral links, earth bus etc. including control wiring with 1.5sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor single core cable for voltage & current respectively, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears etc. complete as required and after decreasing prickling, phosphating etc with cable gland plate on top, with provision for sealing by KSEB consisting of the following ,(a) Incomer : 1.125A TPN ISOLATOR - 1 No. (b) Bus bar: 125A Aluminium bus bar TPN Aluminium bus bar with heat shrinkable insulation and SMC supports -1set , (c) Outgoing: 1. 240V, 1phase, Cl 1.0, 40A, Digital Energy meter (tested and sealed by KSEB) -10 Nos,2. 32A DP MCB - 10 Nos ,32A Bakelite fuse carrier & bases with 32A HRC Fuses : 1. For cut outfuse - 10 sets (1 nos.)Earth bus : 25 x 3 mm Copper
od26485/2025_2026 MSB - Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.- Incomers-EB Incomer -250A, 25kA, FP Microprocessor based MCCB - 1 Set @ 200A, 250A 415V, 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement- Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, Current, Frequency, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts, Phase angle, THD, Neutral current, Max Demand (with RTC),Events (high-low) with time stamp, Individual Harmonics up to 31st, Meter with Ethernet port - 1 Sets-RYB phase indicating LED lamps with control fuses and switches - 1 set.-- Outgoings160A, 16kA, FP TM Based MCCB - 6 Nos., 125A, 16kA, FP TM Based MCCB - 1 Nos along with LT TOD meters with necessary CT of accuracy class 0.5s(Meter shall be provided by KSEB) with all accessories including cut out fuse set, neutral link, glass vision panel etc. required for complete with all accessories required for complete installation including its connections and inter connections etc. as per schematic layout. Switch gears shall be provided with OC & EF as per KSEI norms. The meter shall be tested and approval shall be taken from KSEBL - 1 Set , Supply, Installation, Testing and Commissioning of main panel.
SOLAR
od23098/2025_2026. SOLAR GRID-INVERTING SYSTEM-Supply, Installation, Testing, and commissioning of on-grid solar photovoltaic Power Plant, Conforming to MNRE Specification as amended, consisting of Mono/Polycrystalline silicon solar cell, Net metering facility, necessary protections, earthing mounted on Aluminium /GI Structure of suitable strength with following components complete as required. a)The solar photovoltaic module capacity of 330 wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part -2, Solar photovoltaic Module conversion efficiency shall not be less than 16.5%, PV Modules used in solar power plants /systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10 years and 80 % at the end of 25 years. b)Power conditioning unit (PCU) of 350- 800 V DC input voltage range and 400 V AC, three phases 4 wire, 50 Hz +/- 2.5hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperatures from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit the grid voltage frequency. c)Data monitoring system complete with all accessories. d)Fixing of array junction box & main junction box with IP 65 Protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc as required f) connection and interconnection by supplying & fixing the required size XLPE insulated copper conductor 1.1 KV grade armored power and control cable between solar modules, main power cable to grid supply PCU Unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc as required .( RATE FOR 1 kWp ) COST/kWp
Supply and installation of LED TV (43 inch) full HD smart LED TV display resolution of clear visual 43 inch Vide screen TV with the specification of an inbuilt speaker, AC power adapter AC power chord, Remote, Batteries, with mounting stand etc complete
od23095/2025_2026. Supply, installation & commissioning of Camera Box
od23103/2025_2026. Patch Cable - Supply, Installation, Testing and Commissioning of CAT6 LSZH Patch Cord with molded strain relief boot & 50u gold plated contact pins - 1 Meter etc. of approved make as required for complete installation.
1.53.1. Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable
1.53.2. Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 2 run of Cable
1.53.3. Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 3 run of Cable
od23117/2025_2026. Supply of Desktop with following specification - Intel Core i5 latest Gen Clock Speed - Turbo Frequency up to 4.6 GHz , minimum ram - 8GB DDR 4 , minimum ssd- 512GB+ 1TD hard disk with standed make motherboard , power supply unit , CPU Cooler , ,minimum with Graphics card support , Screen Size -22 inc, Full HD, IPS, micro-edge, Anti-glare , Screen Resolution - 1920 x 1080 Pixel , Wireless LAN-Wi-Fi 6 (2x2) and Bluetooth 5.3 wireless card,v5.2, Web Camera- Wide Vision 720p HD camera,Keyboard-Full-size, backlit,numeric keypad,HDMI Port-1 x HDMI 2.1 and wireless connectivity for wifi connection and bluetooth connection , Operating System- Windows 11 Home with lifetime activate microsoft office , USB Port- 2 x USB-A 3.2 , 2 x USB-C ,Speakers -Built-in stereo speakers ,, one micro SD card slot , standed make keyboard , mouse , one year manufacturer Warranty , with UPS having minimum backup 1 hr with standed Make
od25129/2025_2026. Supply, Installation, Testing & Commissioning of surveillance type Hard Disk having Capacity of 4TB Hard Disk specially designed and manufactured for NVR. The SATA HDD shall be having transmission speed of 6Gb/s and with a cache memory of 64MB
od25130/2025_2026. Supply, Installation, testing & Commissioning of 32 Port CAT 6 PATCH PANEL LOADED
od25131/2025_2026. Supply, Installation, testing & Commissioning of 32 PORT POE SWITCH
od25132/2025_2026. Supply, Installation, testing & Commissioning of Outdoor Weatherproof Heavy Duty CCTV Security Surveillance Cameras Housing Mount Enclosure suitable to mount on wall with hinged cover on front and back, adjustable camera tray and openable top swing.
od25133/2025_2026. Supply, Installation, Testing & Commissioning of 32 Channel Network Video Recorder r suitable to support cameras upto 8MP at 160mbps or higher , Supports 4K, 2 HDD SATA supports upto 8TB each , HDMI,VGA support, H264/H.265 Compression.Two year warranty. The unit shall be provided with HDMI Cable upto monitor, wireless mouse, power assembler with LA and other necessary connections.
od25134/2025_2026. Supply, installation, testing & Commissioning of outdoor type 4 MP high performance COMS bullet camera with resolution not less than 2560 × 1944 @20 fps, provided with 6mm lens having IR Cut filter. The camera sensitivity shall not be less than Color: 0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR and working on EXIR 2.0, DNR and WDR. The camera unit shall be IP67 type and working on POE I/O with RJ45 interface.
od25174/2025_2026. Supply, installation, testing & Commissioning of outdoor type 4 MP high performance COMS bullet camera with resolution not less than 2560 × 1944 @20 fps, provided with 2.8/3.6mm lens having IR Cut filter. The camera sensitivity shall not be less than Color: 0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR and working on EXIR 2.0, DNR and WDR. The camera unit shall be IP67 type and working on POE I/O with RJ45 interface.
od25175/2025_2026. Supply and Installation of Steel Frame 4U Wall Mount Rack, Configured for standard racks are welded frame integrated with side panels and vented top cover with fan mounting provision, while front glass with lock & key provides the visibility. Racks are fabricated out of CRCA steel, CNC programmed, punched, bended, welded and Powder coated with pretreatment process meeting all industry standards.
od24885/2025_2026. Supply, installation, testing and commissioning of 3phase, 415 V, 0.8 PF 50 Hz radiator cooled DG set of the rating 82.5 kVA Prime Duty Diesel Generator Set comprising of diesel engine alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories provided with standard control panel as per the norms of KSEI. The battery charger of auxiliary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge performance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc as required for complete installation. The Generator set shall have a integral type acoustic enclosure as per the CPCB 4+ norms. Diesel engine shall be turbocharged and aftercooled engine suitable for continuous operation. Erected on suitable platform provided with Diesel fuel not less than 75% of Tank capacity along with ADBlue and all necessary accessories etc as required.
FIRE PUMP
od24610/2025_2026. Supply, Installation, Testing and Commissioning of Pressure Switch having 1/4" BSP (F) connection IP - 32 enclosure protection, pressure range 0 to 200 psi with necessary contact.
od24611/2025_2026. Supply, Installation, testing and commissioning of Pressure Guage, 4" dial, 0- 200 psi range 3/8" BSP weather proof with stainless steel internals, siphon tube including fittings etc
od24612/2025_2026. Supply, installation, testing and commissioning of Motor Control Panel for Fire pumps incorporating starters and Switchgear suitable for the motor HP. The control panel shall be duly painted with 2 coats of anti-corrosive primer and Epoxy paint of Fire Red Color fabricated out 16SWG CRCA Sheet floor mounted type with all accessories as required etc. complete with Control and Power terminals, etc.with the following complete with all accessories as per Kerala State Electrical Inspectorate Standards
od24613/2025_2026. Supply, installation, testing and commissioning of Electrically driven Terrace pump raced 450 LPM at 24 M head high efficiency volute type with cast iron casting, impeller, pump coupled to a squirrel cage induction motor, totally enclosed fan cooled with supply condition 415V, 3 phases, 50Hz, foot mounted type rated for 5 HP at 2900 RPM .Power cable and Incoming is client scope.
Hydrant System
od24620/2025_2026. S I T C of 2 way Fire brigade Inlet connection fabricated from 100 mm dia MS Class B medium grade pipe comprising of two 63 mm dia gun metal male threaded non return valve.
od24621/2025_2026. Supply, installation, testing and commissioning of Hydraulic Hose Reel drum completed with swinging type drum with 19mm dia Rubber braided hose of 30M. length and Shut off nozzle, with necessary fittings, valves etc. complete.
od24622/2025_2026. Supply, installation, testing and commissioning of single acting Air Release Valve with screwed inlet 20 mm dia etc. 20 mm dia
od24623/2025_2026. Supplying, installing, testing and commissioning of SS Ball valves with fittings of screwed end type. 20 mm dia
od24624/2025_2026. Supply, installation, testing and commissioning of Non Return Valve single Plate wafer type swinch check valve,short pattern type with integral hinge pin disc , nitrile rubber O-ring seat and face sealing as per IS 5312 in PN 1.6 with ISI mark. 100 mm dia
od24625/2025_2026. Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type confirming to IS 13095 with required flanges, nuts, bolts etc. complete. 100 mm di a
od24626/2025_2026.Supply, Installation, Testing and Commissioning of MS"B" class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes or Angles in walls or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrosive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589) 80 mm dia
od24627/2025_2026. Supply, Installation, Testing and Commissioning of MS"B" class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes or Angles in walls or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrosive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589) 100 mm dia
EXTINGUISHER
od24630/2025_2026.Supplying and installing of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. "EXIT" "FIRE EXIT" "FIRE DUCT"
od24631/2025_2026. Supply and installation of Dry chemical powder type 4 Kg ABC Stored Pressure Fire Extinguisher complete with initial charges, Mono Ammonium Phosphate (MAP 90) based zilicon coated powder, pressure indicating gauge, discharge hose with nozzle,, wall mounting brackets etc. and with ISI mark.
od24731/2025_2026. Design, fabrication, supply of electric traction type with machine roomless type, Stainless steel 13 Passenger (910Kg) elevator (including freight & landing charges ,insurance and all applicable taxes and duties in country of origin and in India etc.without GST) and type suitable for operation on 415 V ± 10%, 3 phase , 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec ,electromagnetic brake system, Duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries,Safe landing device and Battery Operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with prerecorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE3 or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoistway complete as per technical specification. Having automatic side opening half portion Glass door, stainless steel car enclosure provided with stainless steel handrails on two sides as applicable in accordance of following details 3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 9.15mtrs. (Shaft Size 1850mm (width) x 2200mm (depth) ) with door opening of 900mm (width) and 2000 mm (height) . complying with the net inside car area as per IS14665 part 3/1) and door opening of 900mm (width) and 2000mm (height). The equipment should be BMS compatible and shall have provision for CCTV installation . All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications with three years warranty
od24732/2025_2026. Design, fabrication, supply of electric traction type with machine roomless type, Stainless steel 13 Passenger (910Kg) elevator (including freight & landing charges ,insurance and all applicable taxes and duties in country of origin and in India etc.without GST) and type suitable for operation on 415 V ± 10%, 3 phase , 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec ,electromagnetic brake system, Duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries,Safe landing device and Battery Operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with prerecorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE3 or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoistway complete as per technical specification. Having automatic side opening half portion Glass door, stainless steel car enclosure provided with stainless steel handrails on two sides as applicable in accordance of following details 2 stops & 2 openings and entrance & exit at same side and suitable for travel height of 9.15mtrs. (Shaft Size 1850mm (width) x 2200mm (depth) ) with door opening of 900mm (width) and 2000 mm (height) . complying with the net inside car area as per IS14665 part 3/1) and door opening of 900mm (width) and 2000mm (height). The equipment should be BMS compatible and shall have provision for CCTV installation . All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications with three years warranty
od24734/2025_2026. Design, fabrication, supply of electric traction type with machine roomless type, Stainless steel 10 Passenger (600Kg) elevator (including freight & landing charges ,insurance and all applicable taxes and duties in country of origin and in India etc.without GST) and type suitable for operation on 415 V ± 10%, 3 phase , 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec ,electromagnetic brake system, Duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries,Safe landing device and Battery Operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with prerecorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE3 or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoistway complete as per technical specification. Having automatic side opening half portion Glass door, stainless steel car enclosure provided with stainless steel handrails on two sides as applicable in accordance of following details 3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 9.15mtrs. (Shaft Size 1800mm (width) x 1800mm (depth) ) with door opening of 900mm (width) and 2000 mm (height) . complying with the net inside car area as per IS14665 part 3/1) and door opening of 900mm (width) and 2000mm (height). The equipment should be BMS compatible and shall have provision for CCTV installation . All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications with three years warranty
Shaijal TM (BID ID -2251901)
SWATHY CONSTRUCTIONS (BID ID -2245138)
Bidder Name
SWATHY CONSTRUCTIONS
Shaijal TM
BIJU P DANIEL AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
BOQ_1260622.xls
BOQ • 0.51 MB
174240190.html
Tender Documents • 0.10 MB
174325565.pdf
Tender Documents • 0.13 MB
175869847.pdf
Tender Documents • 0.11 MB
Bankerscert2.pdf
Tender Documents • 0.08 MB
SBDwwhktm.pdf
Tender Documents • 0.74 MB
archdwg.pdf
Tender Documents • 7.73 MB
strdwg.pdf
Tender Documents • 4.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .