Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹3.6 L+₹20,238.15 (5.98%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹3.6 L+₹23,039.20 (6.80%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹4.8 L+₹1.4 L (41.6%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
28 Jan 2020, 6:00 pmClosed
AGE (I) Dharamshala HP
AGE (I) Dharamshala HP
Repair to street light at Charri Camp and Military Station Dharamshala
2019_MES_310745_1
AGE(I)/DSL-47/2019-20
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Dharamshala and Charri Camp
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) MES Dharamshala HP
₹12,000
Yes
14 Feb 2020
31 Dec 2019
29 Jan 2020
31 Dec 2019
28 Jan 2020
15 Jan 2020
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Sand cushioning for under ground cables complete all as specified and directed by Engineer-in-Charge.
Brick covering with sub class 'B' brick, old size, brick covering laid dry, flat transversally along the length of cable on sand cushioning with width equal to the length of the brick complete all as specified and directed by Engineer-in-Charge.
Structural steel work in replacement of existing unserviceable cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts,bolts ,washers,welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable GI tubing, light grade, 50mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable SVL/HPSV fitting with new new generation energy saving and environmental friendly long life LED street light 60watt made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device including GI bracket of 40 mm bore 1.5 mtr long bent to any shape required as per site and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box complete all as specified and directed by Engineer-in-Charge. Make:-Havells cat part No.ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent in Crompton / Bajaj.
Replacement of existing unserviceable SVL/HPSV fitting with new new generation energy saving and environmental friendly long life LED street light 70watt made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device including GI bracket of 40 mm bore 1.5 mtr long bent to any shape required as per site and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat part No ENDURAPEARLPLUSSL70WLED757SASYTOPC or equivalent in Crompton/ Bajaj.
Replacement of old and weathered ACSR aluminium conductor of size 6/2.11 or 6/2.59 squirrel weasel and with aluminium binding wire on poles etc straightening / tightening with mechanical devices complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable Shackle type insulators, porcelain, vitreous, white, brown or green, working pressure 1100 Volts of 90mm dia, 75mm height including galvanized mild steel strip of size 31x3mm, size 12mm dia insulator bolt, washers and nuts complete all as specified and directed by Engineer-in-Charge.
Replacement of galvanised steel wire 4mm dia to earth wire on HT/LT poles for fabrication of cradles hexagonal/rectangular guards out of galvanised steel wire 4mm dia etc complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 35 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
All as per Srl No 14 here-in-before but of size 16 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl No 14 here-in-before but of size 16 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable choke electronic, single phase, 220 volts, AC supply 4X14 watt, complete all as specified and directed by Engineer-in-Charge. Make : Polycab Cat part No.PCBE 414 T HFP or equivalent in Havells/Wipro.
Replacement of existing unserviceable compact fluorescent lamp 18 watts, pin type complete all as specified and directed by Engineer-in-Charge. Make : Bajaj/Crompton Greaves/Havells/Wipro/Polycab
Replacement of existing unserviceable compact fluorescent lamp 11 watts, pin type complete all as specified and directed by Engineer-in-Charge. Make : Bajaj/Crompton Greaves/Havells/Wipro
Replacement of existing unserviceable fluorescent tube rod 1x14 watt complete all as specified and directed by Engineer-in-Charge. Make : Bajaj/Crompton Greaves/Havells/Wipro
Supply and fix in replacement of 25 watt LED new generation post-top energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including necessary electric connection complete all as specified and directed by Engineer-in-Charge. Make: Havells Model CORAL (OPAL) IP65, Cat Part No :CORALPT25WLED757PSYMTOPC or equivalent in crompton/wipro.
Replacement of existing unserviceable driver for LED fitting of capacity 45 Watt all as per sample complete all as specified and directed by Engineer-in-Charge.
Replacement of existing unserviceable driver for LED fitting of capacity 72 Watt all as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge.
Painting to existing steel tubular poles 11m long including cross arms, clamps etc. with two coats of aluminum paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC coping including preparation of old painted surface by scraping complete all as specified and directed by Engineer-in-Charge.
Cutting of existing road/ floor/ plinth/drain for taking out/laying of UG cable through GI pipe including necessary earth work, excavation and making good to match with existing surface with PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) complete all as specified complete all as specified and directed by Engineer-in-Charge.
Cutting/trimming tree branches along the over head HT/LT lines up to 2.0 mtr from electric line on both sides of the span and disposing of the cut tree/branches at places complete all as specified and directed by Engineer-in-Charge.
ess are electricals and electronic
Mahashakti Enterprises
KISHAN CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .