Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC D NO CC XX 1487 B1 CC 18 1786 B1 NEAR VVLP SCHOOL KONAM PALLURUTHY P O KOCHI 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹8.7 L+₹34,075 (4.08%)Rejected-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹8.8 L+₹41,755 (5.00%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
28 Feb 2024, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
REPAIR/REPLACEMENT OF STREET/SECURITY LIGHTS LT UG CABLES, REPAIR MAINT FOR DG SETS, AND CONTROL PANELS AND CONNECTED WORKS AT SMA RAMESHWARAM UNDER GE FORT KOCHI
2024_MES_638853_1
8988/E8/GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹19,000
Yes
6 Apr 2024
24 Jan 2024
6 Mar 2024
24 Jan 2024
28 Feb 2024
9 Feb 2024
Amount
M & L repairs to unserviceable street/security/solar light fittings of LED, of any wattage and size by taking down from poles/buildings after disconnecting the electric connection, renew the unserviceable drive ,PVC connector etc, cleaninng, refixing the light fittings at its original position after rectifying the defects and connecting to street light feeder including testing complete all as specified and directed. Note for item No1: (i) Renewal of parts will be measured and paid seperatily as supply only (ii) The cost of labour and tools required for renewal of parts shall deemed to include in the unit rate quoted by the contractor.
Supply only LED driver suitable for LED street light/flood lights 25 to 70 watts 230V compatible with LED Luminaire at site in all aspects all as specified and directed .
Supply only LED driver suitable for LED street light/flood lights 70-90 watts 230V compatible with LED Luminaire in all aspects all as specified and directed .
Supply only LED driver suitable for LED street light/flood lights 100-150 watts 230V compatible with LED Luminaire at site in all aspects all as specified and directed .
M&L for factory made and Outdoor type powder coated CRCA sheet 1.6 mm thick suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system with prov of programmable timer switch for street lights (digital timer setting with mansoon/summer/winter etc) with three phase contactor 20 amps , 10 amps MCB TPN including taking down complete all as specified and directed
Supply and fixing in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fixing in repair post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete complete all as specified and as directed.
Supply and fixing in repairs LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in repairs LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in repairs LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed .
Supply and fix in repair energy saving LED Garden light of 9 W LEDs made up of aluminium casting with acryllicdiffuser for soft illumination effect and the bollard trunk is of black powder coated complete all as specified and as directed
Supply and fixing SMC junction box size of 300x200x105 mm fixed on pole including provision of MCB SP 20 Amps fixed on rail inside box with proper hinges locking arrangements with provision of clamping accessories complete including taking down old unsv item all as specified
Supply & Fix 2 core, 6 Sqmm PVC flat weather proof aluminum cable including taking down old unserviceable cable of any size complete all as specified.
Supply & Fix 2 core, 10 Sqmm PVC flat weather proof aluminum cable including taking down old unserviceable cable of any size complete all as specified.
M & L applying a coat of cement base paint to PCC Pole 9 metre long and writing pole number with synthetic enamel paint (White with black base) including applying a coat of aluminium paint to FI Clamps/ Brackets and applying oil paint black and yellow colour alternatively upto 1.2 mtr from ground complete all as specified.
M & L preparation of old steel surfaces over 10cm width or girth not otherwise described and applying a coat of synthetic enamel paint to steel tubular pole complete all as specified.
Supply and fix in repair PVC insulated 3 core copper conductor cable of size 1.5 Sqmm sheathed 1100 volts including pvc conduit pipe conforming to IS 694 from junction box to street light fitting , all as specified and directed
M & L for drawing wiring complete with two run 1.5 sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade multistranded with copper conductor(ISI Marked) drawn through PVC conduit ,with one run of 1.5 sqmm FRLS single core multistranded copper conductors as earth continuity conductor including dismantling unserviceable wiring including accessories complete alls as specified and as directed.Note:(1) Two runs of cable & one run of earth continuity conductor shall be measured as one running meter.
Supply and fix in repair GI bracket made out of GI pipe 25/32 mm dia medium grade, 1.5 mtr long bent to shape and fixing on poles with MS clamps of suitable sizes etc complete, all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep for laying /removing of cable/ erection of poles in Soft loose soil all as specified and directed by Engr in Charge
M&L riddled sand for cable cushioning in trenches all as specified and as directed. Note : Thickness of sand cushioning after punning down will be measured and paid.
Supply and lay sub class "B" burnt bricks of size 23x11.5x7.5 cm, laid length of brick perpendicular to length of cable complete all as specified and directed.
Returning and filling in of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified.
Supply and jointing as in repair straight through joint ,outdoor type 1100 volts grade ,heat shrinkable type suitable for 4/3.5 core ,10 sqmm to 25 sqmm LT,XLPE cable and testing after jointing complete all as specified and as directed.
M & L for PCC (1:3:6) ,Type C-1,(using 20 mm graded stone aggregate ) as in coping and the like including weathering,slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings not exc 15 cm thickness (below or above ground level) for laying UG cable or any other purpose complete all as specified and directed
Supply and fix in repairs indicating lemps LED type set (R,Y,B) all as specified and directed.
M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 10 sqmm 2 core cable 1100 volt grade ,Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed.
-Ditto- all as per item No 31 but 16 sqmm 4 core cable
-Ditto- all as per item No 31 but 25 sqmm 4 core cable
-Ditto- all as per item No 31 but 50 sqmm 3.5 core cable Note for item No 31 to 34 : Necessary earth works sand cushioning cable protection cover GI pipe etc will be measured and paid separately under relevent items.
M&L for fixing 40 mm dia GI pipe light grade for cable protection including taking up of old unseviecable pipe all as specified and as directed
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to GI strip of 25x3 mm by means of nut, bolts, check nuts and washers of galvanized iron or steel as shown in electrical plate No. 3, including necessary earth work and excavation , charcoal dust, common salt, PCC chamber, RCC cover 40mm thick 1:2:4 using 20mm graded stone aggregate reinforced with 6mm dia round bars 75mm C/C both ways, test point and watering pipe complete, including connecting to earthing test point or to DB / Panel complete as directed by Engr in charge and testing resistance etc complete, including taking down old earthing complete all as specified and as directed. Note: (i)The rate quoted shall be deemed to be included for main earth lead from earth electrode to test point up to 7.5 m only. (ii) On testing after completion if the desired earth resistance not obtained as per IE rules the earthing will be redone by the contractor as directed by Engnr in charge with out any extra cost to Govt.
M & L for Inspection and carrying out B-Checks of 380 KVA DG Set Once in Six months or 300 Hours of Run whichever is earlier installed at various locations by representative / authorised Service Engineer of OEM of the DG Set including inspection, maintenance, changing all types of filters and servicing of DG Set including Alternator, Non AMF / AMF Panels connected to DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Oil Bath Cleaner Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, cleaning of Oil Bath Air Cleaner Tray Screen, check / adjust Belts, checking Battery Voltage, Water Level and apply Jelly on Terminals, checking Fan Hub / Air Blower Hub and Water Pumps, cleaning of electrical connections with CTC solution, checking of safety controls, cleaning of Cooling System, cleaning of Engine and Radiator Assembly, including cleaning of Air Filter using Pressure Air, Corrosion Inhibitor, O Ring, Gaskets, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including applying Grease, CRC in moving parts and draining out water from radiator assembly and refilling new after mixing with coolant including tightening of all inlet and outlet connections and replacing minor items such as Hose Clamp, Screws, Washers etc., cleaning of Roof, Floor of the DG Set Room complete all as specified and as directed. Overhauling periodic servicing of DG sets on-site complete to engine and alternator, consisting of normal periodic repairs, whenever by checking of pulleys/belts, checking desired output values of alternator, and checking for any defects, allignment and rectification of the same for smooth operation. replacement of defective / worn out parts by new spares such as filters, gaskets , V belts, rubber hoses , worm drive clamps ,nuts & bolts and cleaning of alternator with vaccum cleaner complete for DG Set 380 KVA capacity in various locations. Note : - Spares will be measured and paid in relevant item.
-Ditto- all as per item No 37 here in above but for DG Set 100 to 160 KVA capacity
Supply only Air filter element suitable for DG Set 380 KVA capacity all as directed.
-Ditto- all as per item No 39 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
Supply only oil filter assembly including element suitable for DG Set 380 KVA capacity all as directed.
-Ditto- all as per item No 41 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
Supply only fuel filter assembly including element suitable for DG Set 380 KVA capacity all as directed.
-Ditto- all as per item No 43 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
Supply only Radiator fan belt set suitable for DG Set 380 KVA capacity all as directed.
-Ditto- all as per item No 45 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
Calibration and overhauling of fuel injection pump and complete injection system incl injectors from the authorised dealer to make the FIP functional incl tuning it in the engine to receive optimum exhaust out put for DG Set 380 KVA capacity all as directed.
-Ditto- all as per item No 47 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
Dismantling of radiator, overhauling & cleaning by descaling with acid, removal of leakage by welding brazing & refixing it duly repaired complete upto DG Set 380 KVA capacity all as directed.
M&L for fixing in repairs, push button suitable for 230/12 Volts AC/DC as required at site including making connections complete all as directed..
Overhauling periodic servicing of engine consisting of normal periodic repairs, whenever by checking of pulleys/belts, checking desired output values of alternator, and checking for any defects, allignment and rectification of the same for smooth operation. replacement of defective / worn out parts by new spares such as filters, gaskets , V belts, rubber hoses , worm drive clamps ,nuts & bolts and cleaning of alternator with vaccum cleaner complete for Engine of capacity 92 HP in various locations.Note: Spares will be measured seperately under relevant item
-Ditto- all as per item No 51 here in above but for Engine of 56 HP capacity.
Supply only Air filter element suitable for Engine 92 HP capacity all as directed.
-Ditto- all as per item No 53 here in above but for Engine of 56 HP capacity.
Supply only oil filter assembly including element suitable for Engine 92 HP capacity all as directed.
-Ditto- all as per item No 55 here in above but for Engine of 56 HP capacity.
Supply only fuel filter assembly including element suitable for Engine of 92 Hp & 56 Hp capacity all as directed.
Supply and fix belt suitable for Engine 92 HP capacity including taking down of old item all as specified and as directed.
M&L for topping up of coolant anti-freeze in pre-mixed condition brought to site in sealed containers and topping up of the same when and where as directed in DG Sets of capacities 100 to 380 kVA and fire fighting engine as required at site.
M&L for topping up of distilled water zero TDS, brought to site in sealed containers and topping up of the same when and where as directed in batteries of capacities upto 180 Ah as directed by Engr in Charge.
M & L for supply, fixing 4 Pole contactor 415 V AC, Amps rating 200, 415/240 V coil supply voltage including taking down of existing item all as specified and as directed
Supply, installation and commissioning of AVR in 380KVA/ 100 KVA / 160 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load including taking down old item all as directed by Engineer-in-Charge
M&L taking down of High Mast Lights by manual/motor operated for carrying out repair works in the light fitting and applying Greasing, Oiling, etc.on rope , Re-hoisting high Mast Lights after carried out necessery repair works all as specified and as directed. NOTE : Spares/Parts will be Measured and Paid separately under respective Items as 'Supply only'.
M& L for complete scraping of existing paints from fire fighting engine of capacity upto 92 HP/ DG Set of capacity upto 380 KVA thorough cleaning the surface from oil wet, rusted areas, applying 1 coat of metal primer and followed by two coats of synthetic enamel heat resistant paint by air compressor spray 2 coating all as specified including writing the SM / MES Nos. all as directed by Engineer-in-charge
M&L for fixing, installation, testing and connecting of maintenance free tubular Battery of capacity 180 Ah 12 volts with charged/discharged and water level indicators including taking down of old damaged battery, all as specified. and as directed.
M&L for cleaning of fuel tanks of DG Sets mounted in any position by draining out fuel and keeping aside in safe custody and refilling of the same after cleaning of deposited sludge and all visible impurities for DG Sets installed at SMA Rameswaram 100-380 kVA all as directed by Engr in charge.
M&L for Engine Oil 15W40 in sealed HDPE container opened at site and toping up/refilling in DG Sets after draining of unserviceable engine oil by qualified meachanic as and when directed by Engr-in-charge.
Supply & Fix in onload change over switch 4 pole 400 Amps capacity including taking down of unserviceable item complete all as specified and as directed
S & F 4 pole 415V ,25 kA, MCCB 160 Amps with over load adjustable thermal release and short circuit adjustable magnetic type with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete including taking down old unsv MCCB as specified and directed by Engineer in Charge.
S & F 4 pole 415V ,25 kA, MCCB 125 Amps with over load adjustable thermal release and short circuit fixed magnetic type with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete including taking down old unsv MCCB as specified and directed by Engineer in Charge.
-Ditto- all as per item No 70 but MCCB 100 Amps
-Ditto- all as per item No 70 but MCCB 63 Amps
M&L for taking down existing unserviceable UG cable all as specified and as directed
Supply and fix all in one solar LED illuminaries of capacity 40 W,battery capacity 18 Ah,autonomy 2 days mounting height 5 m,working temperature -10 °C to +55 °C including taking down of exisiting lights all as specified and directed.
M&L for pouring of salted water in to each earth pit through water pipe , minimum of 100 Ltrs dissolved with 5 Kgs of common salt to each earth pits / electrodes at various sub staions / buildings for improving the earth conditions , all as specified and as directed. Note :- . The contractor has to arrange wate and transport to various sub stations / installations for the above purpose and Testing of Earth resistance of Electrical earthings of various types , at various Buildings / sub stations by using digital type Electrical earth Tester instruments , registering the test results in the prescribed proforma including cleaning the earth chamber , identifying the earth lead wire , testing and writing by paint the test reults, date of testing etc. on the chambers all as specified and as directed . The job/test will be carried out in the presence of department staff and deatils registered all as specified and as directed.
M & L for cleaning of surrounding of pump house and DG sets by cutting bushes and trimming grass once in two months all as specified and as directed.
AR Traders
N.O. Antony Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .