Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹28.4 L Quoted ₹28.7 L | L1 | Accepted-AOC ok |
| 2 | L2₹31.6 L+₹2.9 L (10.3%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹31.6 L+₹2.9 L (10.3%) | L2 | Rejected-AOC ok |
| 3 | L3₹31.9 L+₹3.2 L (11.1%)Rejected-AOC 239 PHASE 2 MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | ₹31.9 L+₹3.2 L (11.1%) | L3 | Rejected-AOC ok |
| 4 | L4₹33.2 L+₹4.5 L (15.8%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹33.2 L+₹4.5 L (15.8%) | L4 | Rejected-AOC ok |
| 5 | L5₹34.5 L+₹5.8 L (20.1%)Rejected-AOC | ₹34.5 L+₹5.8 L (20.1%) | L5 | Rejected-AOC ok |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
26 Jul 2023, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR/MAINT AND SERVICING OF STP, OIL FIRED INCINERATOR AND MECHANICAL LAUNDARY UNDER AGE E/M-II OF GE DEHRADUN
2023_MES_587787_3
9790/DDN/E8
Open Tender
Civil Works
Item Rate
334 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹73,000
Yes
12 Oct 2023
5 Jul 2023
28 Jul 2023
5 Jul 2023
26 Jul 2023
12 Jul 2023
Amount
Supply and fixing PLC for drying tumbler.
Supply and fixing PLC for washing machine.
Supply and fixing PLC for Hydro extractor.
Supply, fixing, testing & commissioning of bronze globe steam Stop valve flanged of following sizes (IBR certified)
(a) 50 mm bore
(b) 40mm bore
(c) 25 mm bore
Supply and fixing of Gun metal Gate globe or gate valves, with iron wheel head screwed both ends for union pipe and fixed to pipe all as specified and as directed.
(a) 50mm bore
(b) 40mm bore
(c) 25 mm bore
(d) 15 mm bore
Supply and fixing the following type belts :-
(a) V Belt B-59
(b) V Belts B-73
(c) V Belt B-87
(d) V Belt B-92
(e) V Belts B-97
Supply and fixing the following type bearing :-
Supply & Fixing steam solenoid valve 15mmm cap 220 volt single phase of steam brass body ISI mark working at Max 185 o C and working at min operating pressure at 0.5 Kg/cm2 - max operating pressure at 15 Kg/cm2 as per OEM design complete all as specified and as directed.
All as per item No 8 above but of size 20 mm
Supply & Fixing water solenoid valve 25 mmm cap 230 volt single phase of steam vessel ISI mark as per OEM design complete all as specified and as directed.
All as per item No 10 above but of size 40 mm
Supply and fixing flush push type emergency switch suitable for industrial Laundry machines as per OEM design complete all as specified and as directed.
Supply and fixing door gas kit suitable for 60 Kg washing machine as per OEM design complete all as specified and as directed.
Supply and fixing door gas kit suitable for 30 Kg washing machine as per OEM design complete all as specified and as directed.
Supply and fixing steam flexible steel threaded pipe of 15 mm thick and 1 Mtr long
Supply and fixing the contractor following capacity :-
Supply and filling gear oil EP 90 for gear boxed complete all as specified and as directed.
Supply and filling gear oil 20W 40 for boiler pumps complete all as specified and as directed.
Supply and fixing graphite gland packing of 10 mm size for repairing leakages all as specified and directed by Engr in Charge.
S & F teflon pad of iron machine of 1200mmx750mm size per OEM design complete all as specified and as directed.
S&F heating element of iron machine single phase 900-watt 230 volt ISI mark as per OEM design complete all as specified and as directed.
S&F heating element 'U' shape for iron table single phase 3.0 KW 230 volt ISI mark as per OEM design complete all as specified and as directed.
S&F heating element of steam vessel three phase 9 KW cap ISI mark as per OEM design complete all as specified and as directed. Note :- (i) Thread of element should match with vessels thread.(ii) Contractor will ensure that no leakage be from threaded joint of elements."
S&F Aluminium shoes of iron machine ISI mark as per OEM design complete all as specified and as directed.
S&F steam rubber pipe 6 mm of (0-10kg) pressure 3 mtr long nylon embeded of iron machine ISI mark as per OEM design complete all as specified and as directed.
S&F pressure gauge of steam tank of 10kg pressure rating ISI mark as per OEM design complete all as specified and as directed.
S&F single phase micro switch of paddle ISI mark for steam iron press as per OEM design complete all as specified and as directed.
S&F single phase rocker switch 15 Amp cap ISI mark as per OEM design complete all as specified and as directed.
S&F cotton covered copper wire of size 1 sqmm and four core complete all as specified and as directed.
Supply and fix in replacement Wall mounting industrial socket 63 amp cap 5 pin ,3P+N+E 415 volts, AC splash proof IP 67 protected complete all as specified and as directed.
Supply and fix in replacement Wall mounting industrial plug 63 amp cap 5 pin ,3P+N+E 415 volts, AC splash proof IP 67 protected complete all as specified and as directed.
Supply and fix in replacement of MCCB 4 pole 63 Amp cap, breaking cap 16kA suitable for isolation , adjustable overload complete all as specified and as directed.
Supply and fix in replacement of MCCB 4 pole 200 Amp cap, breaking cap 35 kA suitable for isolation , adjustable overload complete all as specified and as directed.
Supply and fix in replacement, PVC insulated, un-armoured, heavy duty electric power cable 6 Sqmm 4 core copper conductor, 1100 volts grade, etc complete all as specified and as directed.
Comprehensive Maintenance for two boilers of cap 600 Kg/Hr - This service will be performed at the start of the maintenance service term. All manufacturers’ recommended yearly maintenance procedures on the unit(s) will be conducted. The inspection will be conducted on a mutually agreeable date(visit). The cost and schedule of maintenance includes the followings :-
(i). Preventative Maintenance - This service provides for regularly scheduled preventative maintenance inspections including descaling if reqd. There will be minimum one Preventative Maintenance visits per month at approximately equal intervals or as recommended by OEM inspection includes following :- • Check the general operation of the unit.• Check the general operation of the unit. • Log the operating temperatures, pressures, voltages, and amperages. • Check the operation of the control circuit. • Check the operation of the motor and starter. • Analyze the recorded data. Compare the data to the original design conditions. • Review operating procedures with operating personnel. • Provide a written report of completed work, operation log and indicate any uncorrected deficiencies detected. • Check & test the functionality of safety devices i.e. pressure release, high temp etc.
(ii). Written Reports - A report will be provided at the end of each inspection with recommendations of necessary repairs and maintenance procedures. Separate report be provided for each boiler.
(iii). Emergency Service - Includes two breakup/emergency calls between inspections as required for the purpose of diagnosis of trouble, adjustment, minor repair, or resetting of controls.
Notes:-
(a) The tenderers shall have to submit the copy of MOU with OEM M/s Thermax company through its authorized service provider as a proof to carry out quarterly/preventive maintenance etc recommended by OEM immediately after commencement of work and strictly follow the company maintenance recommendations. The rates quoted shall be deem to include all such maintenance cost."
(b) The contractor shall submit the record of preventive maintenance service carried out M/s Thermax company along with recommendation of necessary repairs and maintenance procedure along with documentary evidence for claiming payment. The contractor shall produce the ""purchase order"" issued to M/s Thermax company/auth service provider for Annual Maintenance.
(c) Contractors quoted rates shall be deemed to be inclusive of any miscellaneous minor spares such as wires, toggle switch, lugs, nuts, cable gland, connector, thimbles, gland packing etc when required or as ordered by Engr in Charge for smooth and uninterrupted operation of the complete system except spares such as mentioned here in after in relevant items of this schedule.
(d) The item rates include de scaling, cleaning/washing, overhauling of every two month complete all as directed by Engr in Charge failing which a penalty @ Rs 2000/- per two months will be charged.
(e) In case of any major break down the additional manpower if required will be arranged by the contractor to re-start the plant without any additional cost.
Comprehensive Maintenance for diesel fired hot water geyser of cap 300000 K Cal per hrs. - This service will be performed at the start of the maintenance service term. All manufacturers’ recommended bimonthly maintenance procedures on the unit(s) will be conducted. The inspection will be conducted on a mutually agreeable date(visit) and the cost of schedule of maintenance includes following:-
((i). Preventative Maintenance - This service provides for regularly scheduled preventative maintenance inspections including descaling if reqd. There will be minimum one Preventative Maintenance visits per month at approximately equal intervals or as recommended by OEM inspection includes following :-
• Check the general operation of the unit.
• Log the operating temperatures, pressures, voltages, and amperages.
• Check the operation of the control circuit.
• Check the operation of the motor and starter.
• Analyse the recorded data. Compare the data to the original design conditions.
• Review operating procedures with operating personnel.
• Provide a written report of completed work, operation log and indicate any uncorrected deficiencies detected.
• Check & test the functionality of safety devices i.e. pressure release, high temp etc.
(ii). Written Reports - A report will be provided at the end of each inspection with recommendations of necessary repairs and maintenance procedures.
(iii). Emergency Service - Includes two breakup/emergency calls between inspections as required for the purpose of diagnosis of trouble, adjustment, minor repair, or resetting of controls.
Notes:-
(a) The tenderers shall have to submit the copy of MOU with OEM M/s Alfa Therm Limited through its authorized service provider as a proof to carry out bimonthly from OEM immediately after commencement of work and strictly follow the company maintenance recommendations. The rates quoted shall be deem to include all such maintenance cost except material."
(b) Contractors quoted rates shall be deemed to be inclusive of any miscellaneous minor spares such as wires, toggle switch, lugs, nuts, cable gland, connector, thimbles, gland packing etc when required or as ordered by Engr in Charge for smooth and uninterrupted operation of the complete system except spares such as mentioned here in after in relevant items of this schedule.
(c) In case of any major break down the additional manpower if required will be arranged by the contractor to re-start the plant without any additional cost.
(d) The item rates include de scaling, cleaning/washing, overhauling of every two month complete all as directed by Engr in Charge failing which a penalty @ Rs 2000/- per two months will be charged.
(e) In case of any major break down the additional manpower if required will be arranged by the contractor to re-start the plant without any additional cost.
Taking down hydro extractor of 60 Kg complete from its base completely with the help of chain pulley . Note :- The rates of T&P required for taking down of hydro extractor are deemed to be included."
Dismantling the base of hydro extractor of 60 Kg from the platform completely all as specified and directed by Engr in Charge . Note :- The rates of T&P required for taking down of hydro extractor are deemed to be included."
M&L for repairing of main base of the hydro extractor of 60 Kg by the help of lathe work complete satisfaction of Engr in Charge.
M&L for refixing the hydro extractor of 60 Kg at its original position with the help of chain pulley complete satisfaction of Engr in Charge. Note :- The rates of T&P required for refixing are deemed to be included."
Supply only granular based Calcium hypo chloride water disinfectant packed in 45 kgs plastic drums (having 90% free chlorine) for day-to-day use in sewage treatment plant complete all as specified and directed.
Supply & Filling bacteria culture in suitable for MBBR type plant complete all as specified and directed.
Supply only poly aluminium chloride chemical for day-to-day use in Sewage treatment plant complete all as specified and directed.
Supply only DAP for day-to-day use in Sewage treatment plant complete all as specified and directed.
Supply & Filling molasses (Sheera) for day to day use in Sewage treatment plant complete all as specified and directed .
M&L for testing of treated sewage water from out let of chlorine contact tank once in every months from NABL accredited authorized lab as per IS 3025 for recording essential parameters such as BOD, COD, PH, suspended solids and total dissolved solids complete all as specified & directed.
M&L periodical maintenance of drying beds by dislodging of filter media scrapping out the media mixed with sludge to a depth 25 mm to 32 mm removing all floating material, cleaning well from inside, taking out sludge and algae and disposal off to a distance not less than 50 mtrs complete all as specified including digging out filter media up to 150 mm depth for improving the porosity, leveling the media uniformly in filter bed complete all as directed.
M&L for taking down electric motor from base frame and shifting to work shop for rewinding, dismantling and taking out rotor assembly from stator carefully and cutting/cleaning burnt wire from stator, repair to damage slots including rewinding with super enameled copper wire of suitable size, varnishing, drying and tapping with cotton tapes, reassembling, reinstalling at site including testing at full load complete for 15 HP motor complete all as specified and directed.
All as per item No 48.00 above but 7.5 HP motor.
All as per item No 48.00 above but 5 HP motor.
All as per item No 48.00 above but 3 HP motor.
All as per item No 48.00 above but 2 HP motor.
All as per item No 48.00 above but for 1 HP motor.
Supply & Filling of compressor oil 320 grade complete all as specified and directed .
Repair and maintenance to chlorine Dozing plant incl transporting to workshop of manufacture or authorized dealer, dismantling the dozing plant, cleaning, disconnecting electric connection and material and labour for taking out all defective parts and supply and fix new parts for replacement reassembling, testing and re-fixing complete all as directed during execution of work complete all as specified and directed.
Supply and fix replacement of UPVC pipe of normal dia 110mm and outer dia 113mm with sludge delivery pressure of 10 Kg/CM2 complete with all fittings incl elbow, T junction etc and fixing accessories like sockets, nut bolts etc along with PVC solvent cement etc complete all as specified and directed.
Supply and fix replacement of PVC ball valve suitable for UPVC pipe of normal dia 110mm and outer dia 113mm with sage delivery pressure of 10 Kg/CM2 complete with all fittings incl elbow, T junction etc and fixing accessories like sockets, nut bolts etc along with PVC solvent cement etc complete all as specified and directed.
Supply and fix replacement of flange suitable for PVC ball valve/metal body butter fly suitable for pipe of normal dia 110mm and outer dia 113mm with sludge delivery pressure of 10 Kg/CM2 complete with all fittings incl elbow, T jucntion etc and fixing accessories like sockets, nut bolts etc along with PVC solvent cement etc complete all as specified and directed.
Repairing, Overhauling and replacement of dual Filter Media and activated carbon filtration vessels of MBBR STP 0.4MLD including Performing the following:-
(a) Unloading of exhausted filter media from the Filter vessels with proper care etc.
(b) Thorough cleaning and scraping inside the existing Filter vessel properly including painting with two coats of anticorrosive black bituminous paint etc.
(c) Thorough cleaning, scrapping out side of vessel properly including painting with one coat zinc chrome primer & two coats of best quality synthetic enamel paint etc.
M&L for painting of different sizes connecting pipes, valves, panels etc and its related items including writing letters etc as per colour code with one coat of primer and two coat of synthetic enameled paint after making the surface and removing existing paint all as specified and directed
Supply and fix flex electric shock treatment chart with bidding hanger for installation as per sample
Supply only Test Kit for PH and residual chlorine for STP installations
Supply and fix First aid kit for installations at MH DDN.
M&L PVC insulated copper conductor 3 core 1.5 sqmm cable to be drawn inside the pole, including taking down of old one complete all as specified and directed.
Supply & fixing of adjustable type, 3/4" brass fountain nozzles complete all as specified and directed.
M &L for supply, installation, testing and commissioning of submersible pump set electric driven Single phase,50Hz 160-260 volt grade complete with 10 meters submersible cable and suitable starter capacity for motor 1.0 HP. Discharge capacity 3.7 LPS in 12 Mtr Head complete all as specified and directed.
S&F Single phase submersible pump controller suitable for 01 HP motor with over load relay of 6-9.3 Amps and starting capacitor of 100-120 mfd complete all as specified and directed.
Supply & fixing in repair 8-Watt waterproof/ underwater COB LED fountain lights (220 volts AC/24V DC) complete all as specified and directed.
S&F LED in repair focus light 18/20 Watt complete all as specified and directed.
S & F in repair wall mounted water pruifier of minimum capacity 180 Ltrs per hour or higher size 3 stage purification system with water control sensor complete all as specified and directed.
Supply and Laying XLPE insulated galvanized steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 16 sqmm 4 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed.
Supply, assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge.
Supply, Installation, commissioning and testing of LED based ceiling suspended double dome Operation Theatre(OT) light with provision only for suspended Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601 2-41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm to 700mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring for hanging arrangements as per manufacturers guidelines with following specifications incl taking down old unserviceable fittings :-
MAIN DOME SATELLITE DOME Intensity @ 1 meter distance (Lux) : 160000 + 10% 160000 + 10% Adjustable Field diameter (cm) : 14-38 14-38 Depth. of illumination L1+L2(cm) : >100 >100 Color Rendering Index (CRI) (Ra) : 95+3% 95+3% Color temperature (K) : 4500 + 10% 4500 + 10% Intensity control (%) : 25-100 25-100 Control : Dual control Dual control Manual and Remote Manual and Remote Type of field - focusing control : By sterilize able handle By sterilize able handle Type of Intensity control : By control panel on lamp head By control panel on lamp head ELECTRICAL AND MECHANICAL SPECIFICATIONS MAIN DOME SATELLITE DOME Power supply input voltage V 220-230 V 220-230 V Power consumption < 150 watts W < 150 watts W Frequency Htz 50/60 50/60 Dome Diameter 500mm- 700mm 500mm- 700mm LED service life Hrs 4500 + 10% 4500 + 10%
Checking of existing 3x40 TR AC plant complete including required minor accessories, refilling of gas, compressor AHU, cooling tower, LT Panel, AC Duct, Cooling pipe etc. complete all as specified and directed.
Supply & Fixing up to 60 KVA online UPS including microprocessor controlled, comprising of Rectifier, isolation transformer, static switch including By pass arrangement with 32 Nos 12V/100 AH SMF batteries complete all as specified and directed .
Supply install, testing and commissioning LT Distribution Panel (CPRI approved) as per IS / ICE 61439-part I&II, Cubicle type, indoor type, factory fabricated made out of 3 mm thick CRCA sheet outer &
2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links / interconnections shall be insulated with colour coded heat shrinkable sleeve. The cubicle shall have frame work, bottom & 45 CM long 4 legs of size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:3:6 as directed by Eng-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos. danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and air vent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following.
Incoming :-
(a) Insulation epoxy painted high conductivity alluminium bus bar 200 Amps for 3 phase and neutral complete all as specified and directed.
(b) Digital Voltmeter 0 to 500 Volts - 01 set
(c) Digital Ampere meter 0 to 200 Amps capacity - 01 Set
(d) Indicating lamps Neon type for RYB - 01 set
(e) MCCB 4 Pole 415 volts 125 Amps, 16 KA as incoming - 02 Nos.
Outgoing ;-
(a) MCCB 4 Pole 415 volts 100 Amps, 16 KA as outgoing - 02 Nos.
(b) MCB 63 Amps outgoing - 02 Nos
(c) On load change over 125 Amp
M&L required for refilling of 5 KG ABC type fire extinguisher of 70-90% MAP complete including de caning of existing material and refilling with fresh powder with cartridge etc complete incl disposal of existing retrieved material as per CPMB norms complete all as specified and directed .
All as per item No. 77 here in above but 4.5 KG CO2 type.
All as per item No. 77 here in above but 2 KG ABC.
All as per item No. 77 here in above but 10 KG ABC.
All as per item No. 77 here in above but 25 KG ABC.
All as per item No. 77 here in above but 9 KG Foam type.
All as per item No. 77 here in above but 9 Kg CO2 type.
All as per item No. 77 here in above but 3 KG CO2 type.
JS CONSTRUCTION COMPANY
SARASWATI CONSTRUCTION CO
shakti engineering and electrical works
SHRI RAM ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .