| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.3 L+₹40,664 (4.59%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.4 L+₹58,316 (6.58%)Rejected-Finance 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance L3 | |
| 4 | L4₹9.7 L+₹87,096 (9.83%)Rejected-Finance 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | - | Rejected-Technical Non submission of Documents in shortfall stage |
Tender Value
Refer Docs
EMD Value
₹19,943
Closing Date
20 Jun 2025, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Electrical installation and allied works at proposed Saj Ghar, Library Hall Corridor of 3rd Floor and other varrious places of different floor at Vidyasagar Bhawan----SITC of air conditioning system-----as and when required
2025_WBPWD_859744_1
WBPWD/EE/BED/e-NIQ-25/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Vidyasagar Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,943
31 Jul 2025
6 Jun 2025
23 Jun 2025
13 Jun 2025
20 Jun 2025
13 Jun 2025
Amount
SITC of (1.5-1.6 TR) Split type AC machines having cooling capacity range (5.2 kw to 5.3 kw), with fixed/varrious speed rotary comprcssor, refrigerant gas R32, BEE star rating- 3 (EER range 3.5 to 3.99), Air flow range CFM (600-780), both condenser and cooling coils made of copper tube connecting chord with plug top corfirming to IS 1391 (Part-l & Pad-ll) with all amendments (Make: Mitsubishi Electric-RJS18VF/ Mitsubishi Heary-SRK18YXP-W6/O General ASGG38CPTB-B (R32) (As per choice of EIC.)
Supply, Installation, Testing and Commissioning of Split type AC machine having Cooling Capacity range (6.8 kw - 7.7 kw) with fixed/varrious speed Rotary compressor, Refrigerant gas R32 / R410A, BEE star rating - 3, (ISEER range 3.5 to 3.99), Air flow range CFM (780 - 880 or better), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 139 l ( Part - I & Part - II) with all amendments (Make -Mitsubishi Electric RJS22VF/ Mitsubishi Heavy SRK24YYM-W6/ O General ASGGA24CPTBB (R32)As per choice of E.I.C.
Supply and delivery of Cassette Air Conditioner fitted with Rotary / Scroll Compressor: Cooling capacity nominal (K.Cal/Hr): 12000; Cooling Cap(Min) Guaranteed (K.Cal/Hr):10500 ; Min Room Discharge Air Flow (Cu.m/h): 1600. (4 TR) Make: Mitsubishi Heavy / O.General / Daikin as per EIC.
Installation, testing and commissioning Charges for Cassette type A.C machines including making proper arrangements to grout the indoor unit with the ceiling with fass-bolts, Iron Rods & accessories. a)For 4TR Cassette AC
Supply & fixing of pre-fabricated heavy duty MS angle for fixing of Cassette Outdoor unit. a)For 4TR Cassette AC
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 3/8" (9 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl.19mm thick insulation.
5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard 85864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supplying and fixing 6 Core 4 sq mm FRLSH Copper wire for Inter-Connecting Indoor & Outdoor Unit. (Finolex/Havells/RR Cable)
Supply and laying of 1.1 kV grade copper unarmoured round cable of 3 core 2.5 sq. mm from IDU Unit to ODU Unit for the above mentioned AC Unit. [Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]
Supply and laying PVC Drain Pipe 25mm dia with 6 mm thick Nitrile Rubber Insulation. [Make:- Suprime/Oriplast]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage for AC installation, per storey of building per vertical run
Supply & fixing for installation of 01 no outdoor unit of Split type AC Machine by Fabrication of suitable M.S. Structure by 9.75 mtrs 40x40x80x6mm MS U channel, 37.2 mtrs 25x6mm M.S flat & 12.2 mtrs 25x25x4 mm M.S. angle. The platform & gaurdwall of M.S. structure fixed on outside wall of building by cutting hole & necessary scaffolding arrangement incl. mending good the damages by cement concrete as per direction of EIC & painting the fabrication work with one coat of RO primer & 2 coat of oil paint. Approx weight in kg for M.S. structure = 98.64 kg (For 3 nos Outdoor unit = 98.64 kg X 5 = 295.92 kg)
Dismantling of existing old model both indoor & outdoor units for 1.5/2.0 ton A.C machines with own tools & tackles as per direction of EIC and Handed over to the Authority. Note : 1) Suitable quantity of AC machine unit, installtion kit, like, copper pipe, insulation tape, drain pipe, mounting bracket should be stored at site by the Agency in advance with his own responsibility to overcome emergency situations. 2) Works through requisition (i.e, Regular work) should be started within 16 hrs & the emergency breakdown works should be started within 4 hrs with requisite manpower after getting the information either from site or from office. Each individual work must be completed with minimum executing time as per site requirement. 3) The Agency must submit the details of communicating person in this regard along with his Mobile number & Email id.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
NATIONAL AIRCON (BID ID -6604286)
MODERN REFRIGERATION AND ELECTRICAL WORKS (BID ID -6595251)
WEATHER MAKERS INDIA (BID ID -6605244)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .