| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Rates | |
| 2 | L2₹27.9 L+₹1.5 L (5.68%)Rejected-Finance | L2 | Rejected-Finance above price | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Jun 2019, 5:00 pmClosed
Superintending Engineer
107 Nehru Colony, Phase-II, Dharmpur Dehradun
SITC of Addressable type Fire Alarm and Detection System at Vidhan Sabha Dehradun
2019_pwd_17895_1
1517/7CB(I)-11/2019 Dt. 27.5.2019
Open Tender
Electrical Works
Item Rate
180 days
Vidhan Sabh Dehradun
please refer tender documents
2 documents required · 2 mandatory
₹2,950
Executive Engineer EM Div., PWD Dehradun
₹70,000
Dehradun
19 Apr 2021
31 May 2019
19 Jun 2019
31 May 2019
18 Jun 2019
31 May 2019
10 Jun 2019
Amount
SITC of 32 bit microprocessor based fully Redundant TCP /IP networkable. Intelligent addressable Fire Alarm Control panel with 4 loop and shall support up to 30 loops with battery backup for minimum 48 hours. The panel shall be networkable. The control panel, batteries, battery charger etc shall be approved as per standard. The panel should be modular, decentralized, with redundancy in CPU and Power Supply with full functionality. Bidder not having redundancy shall supply 2 panels to comply. The panel shall consisting with minimum 600 character/ 5.7" Touch screen display and at least 5 custom programmable buttons for user specific programmable functional. The panel shall be capable of providing BACnet/ MODbus protocols with 2 way communication for BMS integration. Panel should be able to record at least 10000 events history. Each loop shall be capable to have 250 detector/devices in any combination. The number of loops should be calculated to accommodate all detectors and devices with 20% spares. Vds/UL-FM approved. (Makes: Makes: Bosch FPA 5000 Series/ Siemens Fire Finder XLS series/Edward EST3)
S.I.T.C of intelligent Analog Addressable type smoke detector that combine photo Electronic and fixed temp thermal with inbuilt isolator or isolator base complete with LED Hard Addressable Having rotary decade Address switches, with Mounting Base Complete as required conforming to BS 5839 standards and duly approved by EN54/UL/VDS respect up to the entire satisfaction of Engineer – in Charge of work. (Makes Bosch FAP-425-OT/ Siemens fire finder HFP 11+DB-11+isolator/ Edward SIGA PHS +SIGA IB
S.I.T.C of intelligent Analog Addressable type Rate of Rise/Fixed Heat Detector complete with LED, hard Addressable having rotary decade address switches with inbuilt isolator or isolator base, with Mounting Base complete as required conforming to BS 5839 standards and duly approved by EN54/UL/VDS respect to complete with job in all respect up the entire satisfaction of Engineer – in Charge of work. (Makes: Bosch FAH-425-T-R/ Siemens Fire Finder HFTP11+ DB-11 + ISOLATOR/Edward SIGA DHI+SIGA IB )
SITC of intelligent Analog Addressable type Double Action Manual Call Point with inbuilt isolator or isolator module having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. (Makes: Bosch FMC-210DM-G-R/ Siemens Fire Finder HMS/S / Edward SIGA 278
SITC of Addressable Loop powered sounder and addressable strobe / flasher with inbuilt isolator or isolator module complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.(Makes: (Bosch/ SIEMENS FIRE FINDER/ Edward)
Supply and Laying of PVC unsheathed s/c stranded ( ISI marked ) copper conductor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work MAKE – FINOLEX/ polycab/Bonton
2x 1.5 mm2 PVC unsheathed single core Copper wire DSR NO1.17.2
2x 1.5 mm2 PVC armoured single core Copper wire
Supply and Fixing of PVC Conduit Pipe, 25mm Heavy Duty, ISI Mark with complete accessories. DSR NO 1.21.2 (Make:Polycab/Finolex/ Shetia)
SITC of Addressable Control Relay Module with inbuilt isolator or isolator module flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification(Makes: Bosch/ Siemens fire finder/Edward)
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self-test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.(Makes: BOSCH FMR 5000-13/ Siemens Fire Finder SSDC/Edward 3 LCD ANN)
S/F of Display Type Exit Sign Board
S.I.T.C of 3KVA online UPS WITH 1 Hr Battery Backup. Make : APC/Libert/Emerson
SITC of 15 U Rack Make- Valrack/Comrack/HCL
Tej Security Solutions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .