| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC BALACHANDRAN K R BLOCK DEVELOPMENT OFFICER AMBALAPUZHA | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹5.6 L+₹8,651.61 (1.56%)Rejected-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹5.8 L+₹19,097.15 (3.44%)Rejected-AOC MEDICAL COLLEGE KOTTAYAM PHASE I GENERAL ELECTRICAL WORK ADDITIONAL WORKS OF BASEMENT FLOOR KERALA KL | L3 | Rejected-AOC L3 BIDDER | |
| 4 | L4₹6.2 L+₹65,492.15 (11.8%)Rejected-AOC HARIBHAVAN NORTH ARIYAD P O ALAPPUZHA | L4 | Rejected-AOC L4 BIDDER | |
| 5 | L5₹6.7 L+₹1.1 L (19.8%)Rejected-AOC | L5 | Rejected-AOC L5 BIDDER |
Tender Value
₹7.2 L
EMD Value
₹18,092
Closing Date
13 Feb 2024, 5:00 pmClosed
EXECUTIVE ENGINEER
ALAPPUZHA MUNCIPALITY
AMRUT AMURT project Alappuzha Municipality Development of green cover amp park of Valiyachudukadu phase2 Electrification General Electrical Work
2024_LSGD_653917_1
P/AMT/118460/23-24
Open Tender
Electrical Works
Item Rate
120 days
ALAPPUZHA MUNCIPALITY
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,600
Yes
₹18,092
Yes
18 Mar 2024
3 Feb 2024
16 Feb 2024
3 Feb 2024
13 Feb 2024
3 Feb 2024
Amount
OD347237/2023-2024:Supply, conveyance ,installation ,commissioning of post top lantern suitable for fitting 50mm dia. GI pipe, fitting size 395x275mm, 25 w LED ,metal core PCB fitted in position and giving connection as required. Make HPL/ Bajaj/ Havells. equivalent.
OD347270/2023-2024:Supply & fitting round LED down light philips make model no. DN092B LED 10S-6500 PSU WH or it's equivalent make in recess including cutting slots on ceiling as required and giving connection .
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD345226/2023-2024:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel .
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
15.4.1:Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required1 output per phase and suitable for single phase supply
OD345227/2023-2024:Supply & providing single phase 25A power contactor fitted in position as required.
OD345228/2023-2024:supply & fixing sintex or it's equivalent make box in position as required.size 200x140x95 mm
OD347315/2023-2024:Supply & providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to with stand 11KV dielectric strength.
OD347316/2023-2024:Supply & fitting sintex box with hinged door on wall (GS-MB. 3425, 350 x 250 x 150 mm size) in position as required.
OD345229/2023-2024:Supply & fixing 16A 4 way bakelite connector in position s required
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD345230/2023-2024:Supply & providing 12x3 mm brass bolt & nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required.
OD345231/2023-2024:Supply & providing 25x6 mm brass bolt , nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required.
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.12.1.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
OD345236/2023-2024:Supply & fabricating suitable size support made out of 35x35x5 mm or nearest size angle iron as required including painting as required.
OD345237/2023-2024:Earthing with 40 mm dia. medium class GI earth pipe 2.5 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode)
OD347268/2023-2024:Supply & laying ,jointing of DWC pipe 40/32 mm in the existing trench for protection of UG cable.
OD347269/2023-2024:Supply & laying 20mm dia. flexible PVC conduit in position as required.
OD347271/2023-2024:Supply & providing 50 mm dia /nearest size 'B' GI pipe inserting in the existing gate pillar in position as required for fixing gate light.
OD347272/2023-2024:Supply & fitting Alu. Anodised DNB of size 200x150 mm with inscriptions both in english & malayalam and conventional skull & bone in red colour.
OD347273/2023-2024:Supply & renewal of 6A ,3plate ceiling rose in place of damaged ones
OD347274/2023-2024:supply & providing 25x3 mm copper strip on wall as earth bus.
OD347275/2023-2024:Supply & installation of 0.5 HP centrifugal 1 phase motor pump set v- guard model No. VSPA H-80 with discharge of 1900 to 750 lpm at a head of 6 m to 14 m or equivalent Kirlosker make in position as required.
OD347276/2023-2024:Supply & providing 5 kg / nearest size Dry chemical powder type fire extinguisher with hose & clamps fixing it to wall as required.
OD347277/2023-2024:Painting letters/figures of the following sizes with enamel paint as identification mark to SB,DB,panel board etc. as required. 2.5x4 cm. size
OD347279/2023-2024:Supply & providing anchor bolt hook type on wall/ parapet for binding KSEB service connection cable as required.
OD347278/2023-2024:Charges for preparation of KSEB 3 phase service connection documents for availing 3 phase service connection & producing to the consumer.
OD345240/2023-2024:KSEB three phase connection charges & Concrete support post. actual amount reimbursed producing original bills. Non- competitive rate item.
OD347321/2023-2024:Supply & fixing fiber make motor cover suitable for 1/2 HP motor pump in position as required.
VARGHESE ANTONY
Mighty
HARISH AND CO
AJITH
V and V Electricals
Bidder Name
AJITH
Mighty
HARISH AND CO
BALACHANDRAN K R
V and V Electricals
VARGHESE ANTONY
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1008287.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .