Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹8.8 L+₹10,000 (1.15%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹8.9 L+₹20,125 (2.32%)Rejected-AOC PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-AOC Third lowest | |
| 4 | L4₹9.7 L+₹99,005 (11.4%)Rejected-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC Fourth lowest | |
| 5 | L5₹9.8 L+₹1.1 L (12.7%)Rejected-AOC | L5 | Rejected-AOC Fifth lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
16 Dec 2019, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P)
REPAIR MAINTENANCE AND REPLACEMENT OF LT PANELS SWITCHGEARS SERVICE CABLES AND MISC WORKS AT PALAMPUR MIL STN
2019_MES_297313_1
GEP-49(Token)/2019-20
Open Tender
Civil Works
Item Rate
270 days
Palampur
As per tender docus
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹24,000
Yes
6 Feb 2020
13 Nov 2019
17 Dec 2019
13 Nov 2019
16 Dec 2019
27 Nov 2019
Amount
Excavation in trenches not exceeding 1.5m wide and not exeeding 1.5m in depth and getting out in soft/loose soil for removing/laying of cable etc complete all as specified and directed.
Returning, filling excavated soil in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed.
Removing surplus excavated soil to a distance not exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
Sub class “B” brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal, to length of the brick, complete all as specified and directed.and directed.
GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer complete all as specified and directed of following sizes:-
40 mm bore
50 mm bore
80mm bore
S&F the following component in existing LT Panel boards including disconnecting and taking down at different lacation complete all as specified and directed.:-
Voltmeter Digital type 0- 500 Volts
Ammeter Digital type of 400 Amps capacity
Phase indicator lamp neon type complete with holder assy RYB
CT coils any capacity.
M&L for site clearance of electrical installation/four pole by cleared of shurbs, vegetation cutting of grass, bush, wood trees not exceeding 30cm dia branches and roots and leveling of area and removal of same outside MD land complete all as specified and directed.
Supply and fix in replacement of rubber mat, 1100 Volts of size 2.00m x 1.00m x 10mm complete all as specified and directed.
Supply and fix in repair of danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 20 X 15cm size complete all as specified and directed.
Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ ducts / pipe, on wall, poles of following size and removing unserviceable cable from site to store :-
120 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 3.5 core
16 sqmm 4 core
10 sqmm 2 core
Suplly and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles of following sizes complete all as specified and directed.
120 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 3.5 core
16 sqmm 4 core
10 sqmm 2 core
Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and supply and fixing cable end termination including sleeves heat shrinkable joint suitable for LT XLPE cable of size 16 to 50 Sqmm, 3.5 core complete all as specified and directed.
All as per the description of serial item No 13 here-in-before but of size 70 to 120 Sqmm.
Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 16 to 50 Sqmm, 3.5 core complete all as specified and directed.
All as per the description of serial item No 15 here-in-before but of size 70 to 120 Sqmm.
S&F MCCB suitable for 415 Volts, 3 phase 4 pole thermal magnetic release adjustable type, to be fixed in existing LT Panel and connecting with suitable size terminal contact with stranded PVC insulated copper cable with copper lugs complete all as specified and directed of the following capacity:-
250 Amps four pole (36 KA)
160 Amps four pole (25 KA)
125 Amps four pole (16 KA)
100 Amps four pole (16 KA)
M&L for preparation of existing old painted steel surfaces of any description such as panels any height and painted inside and outside (strictly as per existing shade) complete after scratching existing rusted surface then applying two coats of synthetic enamel paint with colour as directed over a coat of red oxide primer (superior quality) complete all as specified and directed.
Supply and fix in replacement of unserviceable copper bus bar of any size of exisiting LT Panel mounted on insulators including cutting/welding/drilling, making connection and testing all as directed at site.
Supply, installation, testing & commissioning of CPRI approval LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 HZ , AC supply system having busbars chamber with copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 40X40X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:- (A) IN COMMING (a) MCCB four pole 415 Volts AC supply 250 A, thermal magnetic release type 35 KA-01 No (b) Panel mounted multi function meter for measuring Voltage (0-500) Volts Current (0-400 Amps) and frequency-01 No (c) RYB LED indicating lamp panel mounting type (Set of three ) - 01 N0. (B) OUT GOING (a) MCCB four Pole 415 Volt 16 KA 125 Amp rating thermal magnetic relase type -04 Nos. (b) MCCB four Pole 415 Volt 16 KA 63 Amp rating thermal magnetic relase type -01 Nos. (c) MCB SPN 240 Volts 10 KA 20 Amp rating -02 Nos
Supply, installation, testing & commissioning of CPRI approval LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 HZ , AC supply system having busbars chamber with copper bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 40X40X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:- (A) IN COMMING (a) MCCB four pole 415 Volts AC supply 250 A, thermal magnetic release type 25 KA-01 No (b) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current (0-300 Amps) and frequency-01 No (c) RYB LED indicating lamp panel mounting type (Set of three ) - 01 N0. (B) OUT GOING (a) MCCB four Pole 415 Volt 16 KA 125 Amp rating thermal magnetic relase type -03 Nos. (b) MCCB four Pole 415 Volt 16 KA 100 Amp rating thermal magnetic relase type -02 Nos. (c) MCB SPN 240 Volts 10 KA 20 Amp rating -02 Nos
Supply, installation, commissioning and testing LT feeder pillar box outdoor type of size 0.90 mtr x.0.50 mtr x 0.60 mtr factory fabricated made out of MS sheet of thickness 3.15 mm with front door openable with locking arrangement mounted on angle iron legs made out of angle iron size 40 mm x 40 mm x 6 mm, 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30 mtr x 0.30 mtr x 0.50 mtr - 04 Nos, duly painted with two coats of synthetic enemel paint over a coat of red oxide, complete with 200 Amp rated copper bus bar LED phase indicators, suitable for 3 phase 4 wire supply system with MCCB 125 Amp 4 pole breaking capacity 25 KA -01 No, duly drilled holes for cable connection mounted on epoxy based post insulators all as required at site, complete all as specified and directed .
Mild steel galvanised chain link fencing of appropriate size for outdoor transformer of rectangular size of 10' x 12' x 8' with complete supports of 50x6mm angle iron embedded in block of PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) of size 0.30 mtr x 0.30 mtr x 0.50 mtr duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including 1.8 m wide steel gate complete all as specified and directed.
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to galvanized iron strip of size 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 40mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
DWARKA NATH
M/S ASHWANI KUMAR AND COMPANY
malghotra construction co
M/s Sheetal Associates
ranbir singh and Co Govt Contractor and Transporter
M/S RS KAUSHAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .