| 1 | L1₹58.6 LAccepted-AOC | ₹58.6 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹59.7 L+₹1.1 L (1.87%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹59.7 L+₹1.1 L (1.87%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹71.5 L+₹12.9 L (22.0%)Rejected-Finance | ₹71.5 L+₹12.9 L (22.0%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹76.0 L+₹17.4 L (29.7%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹76.0 L+₹17.4 L (29.7%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹80.9 L+₹22.3 L (38.0%)Rejected-Finance LANE NO 02 B BLOCK MANDAKINI VIHAR SAHASTRADHARA ROAD DEHRADUN UTTARAKHAND PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹80.9 L+₹22.3 L (38.0%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹65.2 L
Closing Date
24 Jan 2022, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO. CWE /HILLS /EWS/70 OF 2021-2022 FD ELECTRIFICATION AT AULI UNDER GE 871 EWS
2021_MES_497058_1
CA NO. CWE /HILLS /EWS/70 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
JOSHIMATH
CLASS C
10 documents required · 10 mandatory
₹1,000
GE 871 EWS
Yes
21 Mar 2022
23 Dec 2021
26 Jan 2022
23 Dec 2021
24 Jan 2022
19 Jan 2022
24 Dec 2021 - 13 Jan 2022
Amount
Supplying, design, loading, unloading, installing, testing and commissioning outdoor type floor mounted step down transformer 11000/433 volts (at no load) capacity 250 KVA, AC 3 phase 50 HZ double copper wound oil immerged naturally cooled with external cooling tube core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYn-11 (Vector group) with neutral brought out on secondary side (LV side) and having tapping at 2.5% interval from -7.5% to + 7.5% on HV side having facility to be changed voltage by means of hand operated off load tap changing gear. The maximum temperature rise should not exceed 50 degree Celsius in oil and 55 degree Celsius in HV/LV winding from ambient tempreture when measured by resistance method after continuous full load run in ambient temp of 40 degree Celsius. The transformer shall confirm IS : 1180 and latest relevant IS and ECBC marked and shall comprise of the following :- (a) One cable box on HV side (primary side) with 3 Nos porcelain bushing with arcing horn suitable for 11 KV complete with bushing copper rods, nuts and washers. (b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers with two nos cables glands, suitable for incoming/outgoing of 3 1/2 core 240 Sqmm LT 1100 volt grade XLPE insulated & PVC Sheathed armoured heavy duty cable including glands, joint and jointing materials complete. (c) Oil conservator with filter type drain valve and oil level indicator gauge. (d) De-hydrating breather (TRANSPARENT TYPE) with first fill dehydrating agent (silica gel) (e) Explosive vent. (f) Thermometer pocket with temperature indicator on tank cover. (g) Two earthing terminal's on tank cover to facilitate fixing of 32x6mm galvanised iron earth strip for earthing of neutral & body.
(h) Rating plate and terminal marking plate. (i) Oil drain filter valve. (j) Lifting lugs. (k) Oil filling hole with cap/plug with connecting plate complete. (l) Air release valve . (m) Four plain solid cost steel detachable rollers . (n) Extra bushing for neutral, outside the LT cable box for providing independent earthing for neutral. (o) First filling of new and unused transformer oil IS-335/93 (fourth revision) marked filtered and tested for not less than 50 KV dielectric strength at 2.5 mm air gap between testing electrodes. (p) Brick work foundation suitable for 250 KVA Step down transformer, having 100 mm PCC on top type C1 (1:3:6) at top and PCC B2 (1:4:8) at bottom complete all as directed at site. Note :- (i) Certificate of dielectric strength will be provided by contractor after initial filling of oil.
M&L for switch air break gang operated, outdoor, triple pole mechanically operated mounted on HT 11KV insulators (12 insulators type) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 2 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 3.5 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm 2 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 sqmm 3.5 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 sqmm 3.5 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 sqmm 3.5 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 sqmm 3.5 core complete all as specified and directed.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 sqmm 3.5 core complete all as specified and directed.
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 core complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable including watering and consolidation complete all as specified and directed.
Supply and laying old size sub class 'B' brick burnt clay bricks laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and laying GI steel tube light grade, 40mm bore including necessary GI fitting fixed with clamps, nuts and washers etc, laid in trenches or under floor or fixed with poles/ walls for protection of electric cable complete all as specified and directed.
Supply and laying GI steel tube light grade, 50mm bore including necessary GI fitting fixed with clamps, nuts and washers etc, laid in trenches or under floor or fixed with poles/ walls for protection of electric cable complete all as specified and directed.
Supply and laying GI steel tube light grade, 80mm bore including necessary GI fitting fixed with clamps, nuts and washers etc, laid in trenches or under floor or fixed with poles/ walls for protection of electric cable complete all as specified and directed.
Supply and laying GI steel tube light grade, 100mm bore including necessary GI fitting fixed with clamps, nuts and washers etc, laid in trenches or under floor or fixed with poles/ walls for protection of electric cable complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 meter long) in true vertical positionincluding painting of pole with two pole of Aluminium paint over a coat of red oxide primer including 30 cm alternate step of black and yellow paint up to height of 1.5 Mtrs from top of PCC coping complete with base plate of MS sheet 30 cm x 30 cm x 6 mm thick welded at the bottom of pole, complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
M&L for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, complete all as specified and directed.
M&L for earthing complete with galvansided steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion, complete all as specified and directed.
Supply, install, testing and commissioning of LT Panel board ,CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: Note : Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. (i) MCCB 4 pole 400 Amps 50 kA - 01 Nos (ii) MCCB 4 pole 100 Amps 35 kA - 05 Nos (iii) MCCB 4 pole 63 Amps 35 kA - 02Nos (iv) Multifunctional VAF meter, PF meter - 1 No (v) RYB Neon indicating lamp -1 set for each outgoing and incoming (vi) MS work incl angle iron frame and PCC work (vii) Space for mounting of additional MCB In future.
Supply, install, testing and commissioning of LT Panel board ,CPRI approved ,outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: Note : Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. (i) MCCB 4 pole 100 Amps 35 kA - 01 Nos (ii) MCCB 4 pole 63 Amps 35 kA - 01Nos (iii) MCCB 2 pole 40 Amps 10 kA - 05 Nos (iv) Multifunctional VAF meter, PF meter - 1 No (v) RYB Neon indicating lamp -1 set for each outgoing and incoming (vi) MS work incl angle iron frame and PCC work (vii) Space for mounting of additional MCB In future (viii) Internal wiring including copper lugs
Supply, install, testing and commissioning of LT Panel board ,CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: Note : Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. (i) MCCB 4 pole 63 Amps 35 kA - 01Nos (ii) MCCB 2 pole 40 Amps 10 kA - 03 Nos (iii) MCCB 3 pole 40 Amps 10 kA - 01 Nos (iv) Multifunctional VAF meter, PF meter - 1 No (v) RYB Neon indicating lamp -1 set for each outgoing and incoming (vi) MS work incl angle iron frame and PCC work (vii) Space for mounting of additional MCB In future. (viii) Internal wiring including copper lugs
Supply, install, testing and commissioning of LT Panel board ,CPRI Approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: Note : Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. (i) MCCB 4 pole 100 Amps 35 kA - 01 Nos (ii) MCCB 2 pole 40 Amps 10 kA - 08 Nos (iii) MCCB 3 pole 40 Amps 10 kA - 01 Nos (iv) Multifunctional VAF meter, PF meter - 1 No (v) RYB Neon indicating lamp -1 set for each outgoing and incoming (vi) MS work incl angle iron frame and PCC work (vii) Space for mounting of additional MCB In future. (viii) Internal wiring including copper lugs
Supply, install, testing and commissioning of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: Note : Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. (i) MCCB 4 pole 100 Amps 35 kA - 01 Nos (ii) MCCB 2 pole 40 Amps 10 kA - 07 Nos (iii) Multifunctional VAF meter, PF meter - 1 No (iv) RYB Neon indicating lamp -1 set for each outgoing and incoming (v) MS work incl angle iron frame and PCC work (vi) Space for mounting of additional MCB In future. (vii)Internal wiring including copper lugs
Supply, install, testing and commissioning of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: Note : Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. (i) MCCB 4 pole 100 Amps 35 kA - 01 Nos (ii) MCCB 2 pole 40 Amps 10 kA - 10 Nos (iii) Multifunctional VAF meter, PF meter - 1 No (iv) RYB Neon indicating lamp -1 set for each outgoing and incoming (v) MS work incl angle iron frame and PCC work (vi) Space for mounting of additional MCB In future. (vii) Internal wiring including copper lugs
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation of pole/ stay/ strut, filling and mass concrete etc complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation of pole/ stay/ strut, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in cills, copings, pole pedestals, plinth courses and the like including necessary form work, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
S&F Joist, channel,MS pipe,angle or tee sections as in post and and structs in fencing inch cutting of to shape as directed drilling holes knotching for wire etc flat iron fillet (for securing wire mesh/chain link fencing etc) inch all necessary drilling reveting etc and similar work confirming to Gde-Fe-410-0 or Fe-310-0 complete all as specified and directed.
S&F 4 mm dia GI wire chain link fencing and size of mess 100 x 100 mm fixed to any type of post with straining bolts etc including provn of binding wire complete all as specified and directed.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and directed.
S&F MS framed work such as grills grating etc. with ends of bars sholdered and / or riveted into spikes, framed guard bars / railings and similar work conforming to Fe. 290 Gde-E-165 complete all as specified and directed.
S&F HT lightening arrestor expulson type complete with all fittings transmission class discharge capacity 65 kilo amp suitable for 11 KV complete all as specified and directed.
M&L for cable route indicator fabricated from 50/6 mm angle iron of minimum length 450 mm including CI disc of size 100 mm dia duly engraved (in casting ) HT/LT cable duly reveted wit angle iron at one end and other end duly grouted in ground with PCC (C 1:3:6) of minimum size 30cm x 20 cm x20 cm complete all as specified and directed.
M&L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
S&F disc type insulator, vitreous porcelain white brown or green, over all dimension 140 mm high 240 mm dia and clearance of hole 25.5 mm, complete all as specified and directed.
M&L for ACSR conductor straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete of size 6/1x2.59mm (Weasel), complete all as specified and directed.
Vijaypower Generators Limited
Amit Engineering
KAPOOR ELECTRICALS
M/s Ruchi Rabh associates
M/s Ashok assosiates
Mahamaya Engineers Services
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .