Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 CrAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹42.0 Cr+₹60.2 L (1.45%)Rejected-Finance | L2 | Rejected-Finance L2 Bidder | |
| 3 | Rejected-Technical VILLAGE MANDOUR AMBALA NARAINGARH ROAD AMBALA CITY 134003 HARYANA | AMBALA CITY | AMBALA | HARYANA | 134003 | - | Rejected-Technical Documents not as per requirement |
Tender Value
₹41.5 Cr
EMD Value
₹51.5 L
Closing Date
18 Apr 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, ITPO PD, PWD, GNCTD
Executive Engineer, ITPO Project Division, Flyover Zone, PWD (GNCTD), Bhairon Road T junction Near Pragati Power Station Ring Road New Delhi 110002
Covering of the ramps of all the underpass (entry and exit) ie Underpass 1 to 6 and main tunnel entry and exit ramps, branch tunnel entry ramps developed in the construction of Integrated Transit Corridor Development plan in and around Pragati Maidan
2022_PWD_219989_1
01/CE(Fly)/PWD/GNCTD/2022-23
Limited
Civil Works
Percentage
180 days
Mathura Road, Ring Road, Bhairon Road
Please refer tender document
10 documents required · 10 mandatory
₹0
₹51.5 L
Yes
Office of Chief Engineer Flyover
18 May 2022
4 Apr 2022
18 Apr 2022
4 Apr 2022
18 Apr 2022
8 Apr 2022
4 Apr 2022 - 17 Apr 2022
7 Apr 2022
30 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. | |||||
| 1.01 | Electric resistance or induction butt welded tubes (Mild Steel) | 14,54,243 | Kg | 146.41 | ₹21,29,15,717.63 |
| 2 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete | 2,38,595 | Kg | 116.37 | ₹2,77,65,300.15 |
| 3Providing and fixing Minimum 16mm thick Multicell having min. 45-50 microns Co-extruded UV protected on top Layer (exposed to Sun) and min. 15 micron on other side, over structural steel / MS purlin (to be paid separately) of approved color/shade. Panels shall have width of 700mm – 900mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Polycarbonate Panel System with minimum 5 cells and 6 walls structure shall be uniform in color having integral Tight-Cell/Multicell not exceeding 4mm x 4mm with cross section (Square or Rectangle cell), with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam with the height of min. 14mm at both sides of the panel. Panels shall be fixed on purlins with Fixing system of Continues Aluminum Cleat / Alu.spacer (Fixing System to be approve by Department Or Engineer in charge) along with the vertical standing seam and PC U-connector. Snap-on connectors to interlock the panels shall have a double grip-lock tooth locking mechanism to ensure maximum uplift capability. 16mm polycarbonate Panel ends shall be covered by Polycarbonate End-cap/ Aluminum U-profile/ Glazing bar for ends as per requirement. The weight of the panel shall not be less than 3 kg per square meter (excluding weight of Continues Aluminum Cleat (CW), PC end Cap and Aluminum UPD). | |||||
| 3.01 | The panel system shall confirm the following standards:
1. Dart drop impact test as per IS 14443-97 OR ASTM E 822-81 OR Equivalent test by any NABL Approved Labs. Panel shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155 OR ASTM G154 OR Actual environmental exposure OR Equivalent test by any NABL Approved Labs.
2. Yellowness Index as per ASTM D -1925 OR ASTM E-313 OR Equivalent test by any NABL Approved Labs, and change shall not be more then 10 Delta (DE)/Point change should not be more then 10 when tested on a sample exposed to UV for 500 Hours as per ASTM G 155 OR Actual environmental exposure OR Equivalent test by any NABL Approved Labs.The panel manufacturer shall have and submit manufacturer’s test certificate and undertaking regarding confirmation of above standards in 1 & 2.The panel manufacture shall give 10 years standard warranty for entire system against stability of structure, no sign of breakage of polycarbonate panels and any leakage, and have their own manufacturing plant of sufficient capacity. The contractor shall get the polycarbonate panel approved by Engineer-in-Charge before use. The contractor shall furnish the guarantee on appropriate stamp papers for the entire system for 10 years against stability of structure, no sign of breakage of polycarbonate panels and any leakage. (Approved make of polycarbonate panel system, M/S DANPAL (India) Pvt. Ltd, M/S Coxwell Domes India Pvt. Ltd or equivalent make approved by CE, Flyover Zone). | 41,811 | Sqm | 3,877.26 | ₹16,21,12,117.86 |
| 4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade | |||||
| 4.01 | Two or more coats on new work | 15,511 | Sqm | 136.64 | ₹21,19,423.04 |
| 5 | Supply and Installation of Hilti Anchor Fastener for Fixing of Supporting Bracket with RCC structures including drilling and grouting(Type-1)- Make M16X200 HIT-V (5.8) with dosage of 16ml of HY200 RV3 chemical; Bore Dia 18 mm, Embedment Depth 125 mm minimum, Dispenser HDE 500-A22 | 4,796 | Nos | 1,090.5 | ₹52,30,038 |
| 6 | Supply and Installation of Hilti Anchor Fastener for Fixing of Supporting Bracket with RCC structures including drilling and grouting (Type-2 ,3 & 4)- Make M20X240 HIT-V (5.8)-46ml of HY200 RV3 chemical; Bore Dia 24 mm, Embedment Depth 170 mm minimum, Dispenser HDE 500-A22 | 2,040 | Nos | 2,324.3 | ₹47,41,572 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_284020.xls
BOQ Document • 0.33 MB
95575127.pdf
Tender Document • 0.63 MB
95575129.html
Tender Document • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .