Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC PACHPADRA ROAD OPP MILK DAIRY BALOTRA TEHSIL PACHPADRA DISTT BALOTRA RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹9.1 L Quoted ₹9.5 L | L1 | Accepted-AOC M/S Bhera Ram and Sons is the Lowest Bidder, hence accepted |
| 2 | L2₹9.9 L+₹40,762.68 (4.31%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | ₹9.9 L+₹40,762.68 (4.31%) | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
| 3 | L3₹10.1 L+₹66,551.68 (7.03%)Rejected-Finance 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | ₹10.1 L+₹66,551.68 (7.03%) | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
| Sl No | Description | Qty | Unit | KRISHNA CONSTRUCTION COMPANY L2 | Deccan Enterprises L3 | M/S BHERA RAM & SONS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed. | 75 | CUBIC METRE | 150 ₹11,250 Lowest | 155 ₹11,625 | 341.49 ₹25,611.97 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed. | 31 | CUBIC METRE | 40 ₹1,240 Lowest | 40 ₹1,240 Lowest | 285.16 ₹8,839.84 |
| 3.00 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 44 | CUBIC METRE | 50 ₹2,200 | 40 ₹1,760 Lowest | 123.8 ₹5,447.16 |
| 4.00 | M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed.
Note- Punned down thickness will be measured for payment purpose. | 22 | CUBIC METRE | 225 ₹4,950 | 230 ₹5,060 | 89 ₹1,958 Lowest |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. | 1,558 | EACH | 15 ₹23,370 Lowest | 18 ₹28,044 | 39.34 ₹61,288.6 |
| 6.00 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 150 | RUNNING METRE | 150 ₹22,500 | 145 ₹21,750 Lowest | 172.22 ₹25,832.25 |
| 7.00 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 180 | RUNNING METRE | 190 ₹34,200 Lowest | 195 ₹35,100 | 221.65 ₹39,896.21 |
| 8.00 | Disconnecting and Taking out of old LT armored PVC cables of any size/core/any voltage grade from trenches for replacement complete all as specified and directed. | 330 | RUNNING METRE | 8 ₹2,640 Lowest | 10 ₹3,300 | 8.9 ₹2,937 |
| 9.00 | M & L replacement for PVC insulated and sheathed weather proof two core 6 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed. | 180 | RUNNING METRE | 35 ₹6,300 | 40 ₹7,200 | 17.8 ₹3,204 Lowest |
| 10.00 | S&F in replacement of garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and as directed. | 8 | EACH | 1,400 ₹11,200 | 1,800 ₹14,400 | 1,335 ₹10,680 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Sept 2025, 6:00 pmClosed
Sh Nitish Pathak, EE
GE (AF) Phalodi PIN-342301
REPAIR / MAINT OF SOLAR LIGHTS, DISPERSAL LIGHT AND CONNECTED ITEMS AT AFS PHALODI
2025_MES_728381_1
8735/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Stn Phalodi
As per tender docs
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹20,000
Yes
28 Nov 2025
29 Aug 2025
3 Oct 2025
29 Aug 2025
26 Sept 2025
12 Sept 2025
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Disconnecting and Taking out of old LT armored PVC cables of any size/core/any voltage grade from trenches for replacement complete all as specified and directed.
M & L replacement for PVC insulated and sheathed weather proof two core 6 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed.
S&F in replacement of garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and as directed.
S&F in replacement of unserviceable 35W LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete with all accessories suitable for connection of copper wires complete all as specified and directed.
S&F in replacement of Adjustable thermal & magnetic release MCCB 4 pole 100 Amps, 25 KA rating,Ics = 100% Icu (Icu = 25 kA), 415 volts AC complete all as specified and directed.
S&F in replacement of Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Analog Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 40 Amp load equally distributed over 3 phases. Minimum IP54 Degre of Protection complete all as specified and directed.
S&F in replacement of flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 150 W LED complete all as specified and directed.
S&F in replacement of flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 120 W LED complete all as specified and directed.
Disconnection of street light fittings and refixing,Material and labour in replacement for circuit /sub main wiring from junction box to street light fitting complete with 1.5 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade drawn through PVC conduit in street light poles complete all as specified and directed. NOTE :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc should be deemed to be included in the unit rate quoted.
S&F in replacement of LT Cable junction box outdoor shall be made out of Polycarbonate reinforced and size should be not less than 205mm x 255mm x 112 mm(upto Cable Size 25 sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60695.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60695 - . The Junction Box with Connectors or Terminal Trip or Bus Bar. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no. MCB SP 'B' curved 6-32 Amp and chromium plated clamps and nut bolts, Glands complete all as per manufacturer’s instructions.
S&F in replacement of LED decorative designer pole for LED street light 1X40 Watt, 3.5Mtr Long decorative Double bracket decorative side arms , lighting pole made from CRCA , fixture driver, holder, connector, antiquely designed for architectural street lighting applications and facade lighting applications suitable for mounting double street lights etc prewired including connecting up with 3 core copper cable in flexible pipe with LED Light complete all as specified and directed.
S&F in replacement of Solar Street Light - Luminary of wattage 30 W LED, with epoxy powder coated pressure die-cast aluminium housing with weather proof gasket and heat resistant toughened clear glass cover fixed with SS screw with inbuilt charge controller and auto switch from dusk to dawn operation with ingress protection 65 and suitable for side entry bracket of 20-30 MM OD complete all as specified and directed.
S&F in replacement of energy efficient LED street light fitting of 25 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed.
S&F in replacement of energy efficient LED street light fitting of 45 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed.
S&F in replacement of energy efficient LED street light fitting of 60 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed.
S&F in replacement of Solar Street Light all in one 50 Watt stand alone solar LED Street Light with integrated PV Solar panel, Charge controller, Rechargebale LI Battery pack , Passive infrasensor for dimming operation , Battery charge monitoring cable free Installation fixed with SS screw with inbuilt charge controller and auto switch from dusk to dawn operation with ingress protection complete all as specified and directed.
S&F in replacement of decorative LED light column 3 meter height of 50 watt with cylindrical aluminium pipe housing, opaque diffuser made from engineering grade polymer for rugged outdoor IP 65, complete all as specified and directed.
M&L for preparation of surfaces, scraping of old paint of steel surface of poles and applying two coats of aluminium paint over a coat of red oxide primer of LT steel tubular pole 9 metre hight, single swan neck /double swan neck, Including fixing of reflection tape in altternate coloured of width 6" on poles 1.5 to 1.8 metre above the ground level including writing pole number with black letter under yellow circle complete all as specified and directed. Note :- The tape colour shall be as directed by Engr-in-charge.
S&F in renewal for earthing with galvanized steel plate electrode 600 mm x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.
S&F in replacement of Copper strip 20 x 3.15mm with saddels and fixing screws for roof conductors and down conductors avobe ground ,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required 20X3.15mm copper strip complete all as specified and as directed.
S&F in replacement of GI tube, light grade, 40mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed.
S&F in replacement of GI tube, light grade, 80mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed.
S&F in repairs for rigid non-metallic PVC conduit of 20 mm dia heavy duty alongwith street light poles for wire from junction box to light fittings including fixing arrangement complete all as directed.
M&L for Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate for pole base foundation and coping complete all as specified and as directed.
M&L cement concrete PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in pole foundation complete all as specified and directed.
M&L for 40mm graded stone aggregate for spreading/ loose filling under four pole structure, E/M installation and other placeses where as complete all as specified and directed.
Material & labour for cleaning away all grass vegetation, scalping shrubs bushes under growth roots and trees up to zero level not exceeding 30 cm girth and removing rubbish up to distance of 50 mtr out the periphery of area under cleanness complete with JCB plants/ Manpower complete all as specified and as directed.
S&F in replacement of MCB SP 6 to 20 Amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
Cutting of road / hardstanding upto a size not exceeding 20 cms in width and not exceeding 60 cms in depth for laying of LT UG cable protection piep line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type C1 complete all as specified and as directed.
S&F in replacement LT feeder pillar box factor made cubical type dust proof, out door type both side opening of size 100 x 80 x 40 cm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of 400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate complete incoming / outgoing cable provision complete all as specified and directed.
Material & Labour in rectification of LT cable, fault existing / as and when occurs with diagonising equipments as applicable, and by joining with suitable method to restore supply complete all as specified and directed.
S&F in replacement of LT Cable junction box outdoor shall be made out of Polycarbonate reinforced and size should be not less than 104mm x 104mm x 70 mm The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60695.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60695 - . The Junction Box with Connectors or Terminal Trip or Bus Bar. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 complete all as specified and directed.
KRISHNA CONSTRUCTION COMPANY (BID ID -3436422)
Deccan Enterprises (BID ID -3436438)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .