Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹2.0 LAdmitted-Finance 112 21 A 2 K N MUKHERJEE ROAD P O TALPUKUR BARRACKPORE 24 PGS N | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹2.0 L | H1 | Admitted-Finance |
| 2 | H2₹2.0 L−₹1,319 (0.66%)Admitted-Finance 159 KAILASH GHOSHI ROAD KOLKATA WEST BENGAL 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | ₹2.0 L−₹1,319 (0.66%) | H2 | Admitted-Finance |
| 3 | H3₹1.9 L−₹6,876 (3.44%)Admitted-Finance | ₹1.9 L−₹6,876 (3.44%) | H3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | POWER INDIA H2 | MIK ENTERPRISES H1 | M/S STARLIGHT & CO H3 |
|---|---|---|---|---|---|---|
| 1.00 | The LT panel must be isolated from the power supply before commencement of the servicing work. Proper safety procedures should be followed to ensure the safety of personnel and prevent accidental energization. | 1 | Item | 6,605 ₹7,794 | 6,649 ₹7,846 | 6,420 ₹7,576 Lowest |
| 2.00 | Racking out and drawing out of ACB from LT panel and keeping the ACB in a workable position inside the room.
Open out the ACB cover carefully and complete dismantling of all the parts like roller guide, main drive shaft, S.S pin, silt spring, rechet assembly, trip bridge assembly, male & female contact etc, by the proper tools and tackles engaging expert personel. | 2 | Item | 12,705 ₹29,984 | 12,790 ₹30,184 | 12,350 ₹29,146 Lowest |
| 3.00 | Cleaning of all contact points, arc chutes, insulation barriers, and moving parts should be done thoroughly using appropriate CRC spray or contact cleaner. Dust, carbon particles, and accumulated grime must be removed to restore
dielectric integrity. | 2 | Item | 8,847 ₹20,879 | 8,906 ₹21,018 | 8,600 ₹20,296 Lowest |
| 4.00 | Checking & Tightening of all mechanical parts including operating linkages, tripping mechanisms, and latches should be done for free movement, alignment, and wear. Any loose fittings must be tightened, and worn parts should be replaced with new one. | 2 | Item | 6,800 ₹16,048 | 6,845 ₹16,154 | 6,610 ₹15,600 Lowest |
| 5.00 | Lubrication of all moving components and mechanical linkages should be done with dielectric grease or other manufacturer-recommended lubricants. Care must be taken to avoid over-lubrication or contamination of contact surfaces. | 2 | Item | 6,136 ₹14,481 | 6,177 ₹14,578 | 5,965 ₹14,077 Lowest |
| 6.00 | Removal of carbon deposits, moisture, and dust from the busbar and support insulators using CTC (Carbon Tetrachloride) / Petrol and lint-free cleaning agents. Application of high-grade insulating varnish and re-insulation using heat-shrinkable PVC sleeves or specialized insulating tape (as per requirement). | 2 | Item | 7,469 ₹17,627 | 7,518 ₹17,742 | 7,260 ₹17,134 Lowest |
| 7.00 | Replacement of the worn-out parts such as springs, auxiliary switches, interlocks, contact fingers, or arc runners must be done with new components . | 2 | Item | 7,664 ₹18,087 | 7,715 ₹18,207 | 7,450 ₹17,582 Lowest |
| 8.00 | Reassembly of the ACB should be made properly and mounted back into the panel board. All terminals must be reconnected, and the unit should be aligned and fixed securely to its original position. | 2 | Item | 10,648 ₹25,129 | 10,718 ₹25,294 | 10,350 ₹24,426 Lowest |
| 9.00 | Testing of Insulation Resistance (IR) must be performed using a megger (500V or 1000V). Resistance between phases and phase-to-earth should be measured including Contact Resistance (mV drop) test and to be recorded. | 2 | Item | 1,096 ₹2,587 | 1,103 ₹2,603 | 1,065 ₹2,513 Lowest |
| 10.00 | Functional testing of the ACB should be carried out to ensure proper closing, tripping, manual operation, spring charging, and indication features. After successful testing, the ACB may be commissioned and put back into service under supervision of the EIC. | 2 | Item | 3,570 ₹8,425 | 3,594 ₹8,482 | 3,470 ₹8,189 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
1 Aug 2026, 4:00 pmClosed
Dy. CE ( M/S and D)
25, Tiljala Road , Ballygunge,Kolkata,700039
Complete repairing, servicing,overhauling and testing of 2 nos. ACBs (1250A) including other allied works at Keorapukur SSE PS under Kudghat Unit / (S and D) Department.
2026_KMC_1034065_1
KMC/S_D/KGPS-06/26-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
Kudghat
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4,000
12 Aug 2026
24 Jul 2026
4 Aug 2026
24 Jul 2026
1 Aug 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | The LT panel must be isolated from the power supply before commencement of the servicing work. Proper safety procedures should be followed to ensure the safety of personnel and prevent accidental energization. | 1 | Item | 6,500 | ₹6,500 |
| 2 | Racking out and drawing out of ACB from LT panel and keeping the ACB in a workable position inside the room.
Open out the ACB cover carefully and complete dismantling of all the parts like roller guide, main drive shaft, S.S pin, silt spring, rechet assembly, trip bridge assembly, male & female contact etc, by the proper tools and tackles engaging expert personel. | 2 | Item | 12,300 | ₹24,600 |
| 3 | Cleaning of all contact points, arc chutes, insulation barriers, and moving parts should be done thoroughly using appropriate CRC spray or contact cleaner. Dust, carbon particles, and accumulated grime must be removed to restore
dielectric integrity. | 2 | Item | 8,700 | ₹17,400 |
| 4 | Checking & Tightening of all mechanical parts including operating linkages, tripping mechanisms, and latches should be done for free movement, alignment, and wear. Any loose fittings must be tightened, and worn parts should be replaced with new one. | 2 | Item | 6,650 | ₹13,300 |
| 5 | Lubrication of all moving components and mechanical linkages should be done with dielectric grease or other manufacturer-recommended lubricants. Care must be taken to avoid over-lubrication or contamination of contact surfaces. | 2 | Item | 6,030 | ₹12,060 |
| 6 | Removal of carbon deposits, moisture, and dust from the busbar and support insulators using CTC (Carbon Tetrachloride) / Petrol and lint-free cleaning agents. Application of high-grade insulating varnish and re-insulation using heat-shrinkable PVC sleeves or specialized insulating tape (as per requirement). | 2 | Item | 7,200 | ₹14,400 |
| 7 | Replacement of the worn-out parts such as springs, auxiliary switches, interlocks, contact fingers, or arc runners must be done with new components . | 2 | Item | 7,550 | ₹15,100 |
| 8 | Reassembly of the ACB should be made properly and mounted back into the panel board. All terminals must be reconnected, and the unit should be aligned and fixed securely to its original position. | 2 | Item | 10,500 | ₹21,000 |
| 9 | Testing of Insulation Resistance (IR) must be performed using a megger (500V or 1000V). Resistance between phases and phase-to-earth should be measured including Contact Resistance (mV drop) test and to be recorded. | 2 | Item | 1,100 | ₹2,200 |
| 10 | Functional testing of the ACB should be carried out to ensure proper closing, tripping, manual operation, spring charging, and indication features. After successful testing, the ACB may be commissioned and put back into service under supervision of the EIC. | 2 | Item | 3,520 | ₹7,040 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
Tendernotice_2.pdf
PDF • 0.80 MB
BOQ_2539635.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .