Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.5 L+₹1.3 L (16.2%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹10.4 L+₹2.2 L (26.2%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹11.3 L+₹3.1 L (37.5%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
21 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (I) (CG) Goa
Garrison Engineer (I) (CG) Goa HQ Coast Guard DHQ-11 Chicolna PO- Bogmalo Goa 403806
REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AT GOA UNDER GE(I)(CG) GOA
2023_MES_619175_1
8415/GOA/E8
Open Tender
Miscellaneous Services
Item Rate
180 days
COAST GUARD AT GOA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Goa
₹19,800
Yes
16 Nov 2023
16 Sept 2023
30 Oct 2023
16 Sept 2023
21 Oct 2023
1 Oct 2023
16 Sept 2023 - 23 Sept 2023
Amount
Supply and charging of refrigerant gas R-22/R 134 upto sufficient pressure for compressor of 1.5 / 2 ton capacity window/ split type Acs including connected works like pressure testing with nitrogen before filling of refrigerant gas including cutting of copper tubing and brazing and refixing in position complete all as specified and directed.
S & F in repairs brand new blower motor single phase,220 v,50 Hz suitable for 1.5/2 ton capacity Split AC and testing complete all as specified and directed.
S & F in repairs brand new Condensor fan motor single phase suitable for 2 ton/1.5 ton split / window AC as per existing model including making necessary connection complete all as specified and directed.
S & F in repairs of air swing fan motor, single phase suitable for 1.5 ton/2 ton split / window type AC complete all as specified and directed.
S & F in repairs wiring harmness assembly complete suitable for 1.5/2 ton capacity split / window type AC unit including dismantling the old one all as per manufacturer manual complete all as specified and directed.
S & F in repairs starting relay suitable for 1.5 ton /2 ton split AC capacity complete all as specified and directed.
S & F in repairs connector strips 6 way suitable for 1.5 ton /2 ton capacity split /window AC complete all as specified and directed.
S & F in repairs starting capacitor 100-120MFD suitable for 1.5 / 2 Ton split / window AC complete all as specified and directed.
S & F in repairs running capacitor 36 mfd 7 pin /4 pin suitable for split /window type AC complete all as specified and directed.
S & F in repairs running capacitor 45 mfd 7 pin /4 pin suitable for split/window type complete all as specified and directed.
S & F in repairs fan capacitor 4/6 MFD suitable for window /split type ACs complete all as specified and directed.
S & F in repairs capacitor 50 MFD suitable for 2 Ton Split AC including dismantling the old one complete all as specified and directed.
S & F in repairs condensing coil unit suitable for outdoor unit for 1.5/2 TR capacity split / window type air conditioning complete all as specified and directed.
S & F in repairs cordless remote control for existing split/window type AC complete all as specified and directed.
S & F in repairs insulation for copper tubes of split type AC units using superion quality insulation and size 3/8"dia complete all as specified and directed.
S & F in repairs insulation for copper tubes of split type AC units using superion quality insulation and size 5/8"dia complete all as specified and directed.
S & F in repairs insulation for copper tubes of split type AC units using superion quality insulation and size 1/2"dia complete all as specified and directed.
S & F in repairs insulation for copper tubes of split type AC units using superion quality insulation and size 1/4"dia complete all as specified and directed.
S & F in repairs copper tubing, soft grade, suitable for split type AC suction/ discharge line of 5/8" dia complete all as specified and directed.
S & F in repairs copper tubing, soft grade, suitable for split type AC suction/ discharge line of 3/8" dia complete all as specified and directed.
S & F in repairs copper tubing, soft grade, suitable for split type AC suction/ discharge line of 1/2" dia complete all as specified and directed.
S & F in repairs copper tubing, soft grade, suitable for split type AC suction/ discharge line of 1/4" dia complete all as specified and directed.
S & F in repairs compressor sealed unit suitable for 1.5/2.0 ton capacity of any make, including replacement of copper tubing/ capillary strainer etc, testing and commissioning complete all as specified and directed. [Note:- Warranty certificate shall be produced to Engineer in charge for claiming payment]
S & F in repairs PVC insulated and overall PVC sheathed circuler flexible copper conductor cable of 3 core 2.5 sqmm size complete all as specified and directed.
S & F in repairs PCB (remote control) unit suitable for indoor type 1.5/2 TR capacity split type AC existing make and model complete all as specified and directed.
Taking down indoor/outdoor unit of window/split type ACs of 1.5/2 ton capacity carefully and servicing complete including washing, clearing dust by vaccum cleaner, applying dilute solution to the condenser using spray nozzle, replacements of wornout nutbolts, burnt wiring etc washing/ clearing Air Filter, Cleaning compressor, condenser fan motor, AC capacitor, Control panel, Isolator switch, safety device, Evaporator, coil motor, drain system filters etc reinstalling the same at the same location complete all as specified and directed. (wet and dry service).
S & F in repairs strainer drier for 1.5/2 ton split /window type AC complete all as specified and directed.
S & F in repairs split type AC outdoor unit cabinet complete incuding condenser, condenser motor, blower, blower motor etc but without compresser complete all as specified and directed.
Cutting and removing old rusted bottom portion of including leg of water cooler and supply and fix new legs of existing size/guage made of mild steel by gas or arc welding complete including anti rust paint complete all as specified and directed. .
M & L for Condensor motor 1/32 HP with fan blades complete suitable for 40 to 150 ltr capacity water cooler including taking out old ones including necessary bolts, nuts etc complete all as specified and directed.
S & F in repairs PVC drain pipe 25mm dia with suitable standard clip etc complete fix to water cooler of any capacity complete all as specified and directed.
Supply and charging of F134/R-22 gas for water cooler40/ 80/120/150 ltr capacity including cutting and brazing of copper tubes complete complete all as specified and directed.
S & F in repairs PVC float valve 15mm dia for water cooler complete all as specified and directed.
S & F in repairs Voltage Stabilizer for automatic operation electronic type single phase naturally air cooled indoor type and designed for input variation between 130V to 300 V with output voltage stabilized at 220V with accuracy of plus 5%, 5 KVA capacity complete all as specified and directed. [Note:- Warranty certificate shall be produced to Engineer in charge for claiming payment]
Dhanu Refrigeration
Shree Ram Enterprises
D.K. ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .