Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 CrAccepted-AOC 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹4.9 Cr | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹5.4 Cr+₹52.6 L (10.8%)Rejected-AOC 02 AB ADGAONKAR PLAZA NEAR ABB CIRCLE MAHATMA NAGAR NASHIK 422 007 MAHARASHTRA | NASHIK | MAHARASHTRA | 422007 | ₹5.4 Cr+₹52.6 L (10.8%) | 2 | Rejected-AOC Other Than L1 |
| 3 | 3₹5.8 Cr+₹86.9 L (17.8%)Rejected-AOC | ₹5.8 Cr+₹86.9 L (17.8%) | 3 | Rejected-AOC Other Than L1 |
| 4 | 4₹6.1 Cr+₹1.2 Cr (24.4%)Rejected-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹6.1 Cr+₹1.2 Cr (24.4%) | 4 | Rejected-AOC Other Than L1 |
Tender Value
₹4.6 Cr
EMD Value
₹5.3 L
Closing Date
21 Jun 2025, 6:00 pmClosed
Chief Engineer Pune Zone
HQ Chief Engineer Pune Zone-411001
PROVISION OF GUARD POSTS WITH WATCH TOWERS UNDER GE DEHU ROAD
2024_MES_661185_4
CA NO. CEPZ/MUM/TOKEN-03 OF 2024-25
Open Tender
Civil Works
Lump-sum
630 days
Dehu Road
Class A Category a(i) also refer NIT
8 documents required · 8 mandatory
₹2,000
GE Dehu Road
₹5.3 L
Yes
29 Jul 2025
13 May 2025
28 Jun 2025
13 May 2025
21 Jun 2025
3 Jun 2025
14 May 2025 - 17 May 2025
Amount
SCH 'A PART-I: BUILDING AND STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Construction of Block of Guard Post with watch tower (12.20 m staging above FFL) with Type 'A' foundation complete all as shown on drawings and as specified.
Construction of Block of Guard Post with watch tower (12.20 m staging above FFL) with Type 'B' foundation complete all as shown on drawings and as specified.
Construction of Block of Guard Post with watch tower (12.20 m staging above FFL) with Type 'C' foundation complete all as shown on drawings and as specified.
Construction of Block of Guard Post with watch tower (12.20 m staging above FFL) with Type 'D' foundation complete all as shown on drawings and as specified.
Construction of Block of Guard Post with watch tower (6.20 m staging above FFL) with Type 'E' foundation complete all as shown on drawings and as specified.
Construction of Septic Tank for 25 users all as shown on drawing Nos CEPZ/92/TD/17M Sheet No 1/2 to 2/2 and as specified.
Construction of Soakage well of size 1.20 m dia and 3.00 m deep all as shown in drawing No. CEPZ/2019/TD/03 sheet ½ & 2/2 and as specified.
NOTE: Schedule ‘A’ Part II to X items which are Prepriced by MES, Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Total amount of Sch ‘A’ Part II (Internal Water Supply)
Total amount of Sch ‘A’ Part III (Internal Electrification)
Total amount of Sch 'A' Part-IV (Lightening Protection)
Total amount of Sch ‘A’ Part V (Hardstanding)
Total amount of Sch ‘A’ Part VI (Sewage Disposal)
Total amount of Sch ‘A’ Part VII (Area Drainage)
Total amount of Sch ‘A’ Part VIII (External Water Supply)
Total amount of Sch 'A' Part-IX (External Electric Supply)
Total amount of Sch 'A' Part-X (Site Clearance, Excavation and Earthwork)
NOTE: Schedule ‘A’ Part II to X items, which are not Prepriced by MES are given hereunder, Bidders shall insert their rate in Column-7 only and the Estimated rate indicated as "0.0" are for that purpose.
SCHEDULE 'A' PART-XI (MISC B/R AND E/M WORKS)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas not exceeding 1.5m in depth, in all kinds of soils and getting out the excavated soil, complete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in trenches (not exceeding 1.5m in width or 10Sqm in plan) and not exceeding 1.5m in depth; for foundations etc. or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables etc., including dressing of sides and ramming of bottoms, in all kinds of soils including getting out the excavated soil, complete all as specified and directed.
Supply, installing, testing and commissioning out door type cubicle /KIOSK type totally enclosed, CPRI type tested, factory made, dust and vermin proof, single pin shutter in front, cubicle shall be made of 3.15 mm thick CRCA sheet, framing with 40 x 40 x 5 mm thick MS angle iron and legs grouted in PCC 30 cm deep in ground and 50 cm above ground, duly fabricated and having proper locking arrangement and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and the Panel shall also include all accessories, electrical cables including following items and electrical instruments and other accessories as per recommendation of manufacturer comprising with and including following accessories :-
INCOMING MCB SPN 16 Amps, 240 Volts, 50 Hz, 3 phase breaking capacity 16 KA -01 No OUTGOING (i) MCB SP 10 Amps, 240 Volts, 50 Hz, 1 phase breaking capacity 16 KA -01 No (Guard Post DB) (ii) MCB SP 6 Amps, 240 Volts, 50 Hz, 1 phase breaking capacity 16 KA -01 No (Watch Tower Security Light)
P L ADKE (BID ID -3322502)
haresh n hingorani (BID ID -3323159)
SHAILENDRA B TULSANI (BID ID -3318815)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.37 MB
Tenderdocument.pdf
Tender Documents • 29.78 MB
Tenderdocument_2.pdf
Tender Documents • 1.97 MB
Tenderdocument_3.pdf
Tender Documents • 8.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .