Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.5 L+₹22,000 (9.61%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹6.6 L+₹4.3 L (188.2%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
30 Oct 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NITHIN C S
SM (P AND P) CD
Handling of Slip Plates and Slip Rings in SA Plant,FACT CD during ATA 2023
2023_FACT_776463_1
04097/2023-2024/E28302
Limited
Miscellaneous Works
Item Rate
45 days
AMBALAMEDU
This tender is issued on limited tender basis from the registered bidders of FACT (CD) (selected bidders).
4 documents required · 4 mandatory
₹0
₹5,000
Yes
6 Nov 2023
14 Oct 2023
31 Oct 2023
14 Oct 2023
30 Oct 2023
14 Oct 2023
Handling of Slip Plates & Slip Rings in SA Plant,FACT-CD during ATA 2023.Work Involves:
Removing the slip ring and fixing the slip plate and opening the dummy in 1800 mm dia gas duct (4th bed inlet) during shutdown
Removing the slip plate and fixing the slip ring and closing the dummy in the above duct during start up using sulphur
Fixing slip plate in 1800 mm dia duct (W4 outlet) during RLNG startup
Removing slip plate in 1800 mm dia duct (W4 outlet) during startup using sulphur
Fixing slip plate in 1800 mm dia duct (W6 outlet) during RLNG startup
Removing slip plate in 1800 mm dia duct (W6 outlet) during startup using sulphur gun
Providing vent in bottom manhole of W4 during start up using RLNG
Removal of vent in bottom manhole of W4 during start up using sulphur gun
Providing vent in bottom manhole of W5 during start up using RLNG
Removal of vent in bottom manhole of W5 during start up nusing sulphur gun
Providing vent in bottom manhole of W6 during start up using RLNG
Removal of vent in bottom manhole of W6 during start up nusing sulphur gun
Providing vent in bottom manhole of W3 during start up using RLNG
Removal of vent in bottom manhole of W3 during start up nusing sulphur gun
Removing slip plates in the hot air valves in the duct from 1st bed to 4th bed (2 no) and fixing slip ring during shutdown.
Fixing back the slip plates in the hot air valves in the duct from 1st bed to 4th bed (2 no) with out leak during start up using sulphur
Removing the slip ring and fixing the slip plate in 1800 mm dia gas duct (First bed inlet) during RLNG start up
Removing the slip plate and fixing the slip ring in the above duct during catalyst heating start up
Supply of cable tags, aluminium or SS for cables (cable No. pre-fix will be given at the time of erection)
Supply and Installtion of UG LT Cable Route Marker as per engineer in charge instructions for cable identification
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3.5 cores x 400 sq.mm. through the existing cable tray at Q10 substation 25 mts / excavated trench 85 Mts and cable tray at phosphorc acid dic wall (35 Mts) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3/3.5 x 50 sq.mm. through the existing and newly fabricated cable tray at various locations in Q10 berth installations of FACT, as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3 x 35 sq.mm. through the newly fabricated cable tray at phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 1 core x 70 sq.mm. (2 Run x 110 Meter) unarmoured, earthing cable through the existing cable tray at Q10 substation 25 mts / excavated trench 85 Mts and cable tray at phosphorc acid dic wall (35 Meters) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 1 core x 35 sq.mm. unarmoured, earthing cable through the newly fabricated cable tray at phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 5 cores x 2.5 sqmm armoured coper cable (4 run x 35 Meter) through the newly fabricated cable tray at phosphorc acid dic wall, as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Rerouting and Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3.5 x 185 sq.mm. through the excisting cable tray at phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Glanding and Termination of cable of size 3.5 core x 400 sq.mm. at PAT MCC Incomer and substation out going with suitable lugs and crimping.
Glanding and Termination of cable of size 3.5 core x 185 sq.mm. at PAT MCC Outgoing with suitable lugs and crimping.
Glanding and Termination of cables of size 3.5 core x 50 sq.mm. at various locations in Q10 berth installations of FACT with suitable lugs and crimping.
Glanding and Termination of cables of size 3 core x 50 sq.mm. at PAT to motor terminal (30 KW Motor, 2 Nos.) with suitable lugs and crimping.
Glanding and Termination of cables of size 3 core x 35 sq.mm. at PAT to motor terminal (15 KW Motor, 2 Nos.) with suitable lugs and crimping.
Termination of earthing cable of size 1 core x 70 sq.mm. at PAT MCC and substation with suitable lugs and crimping.
Termination of earthing cable of size 1 core x 35 sq.mm. at PAT MCC to motor terminals at acid P2O5 pump house with suitable lugs and crimping.
Glanding and Termination of cables of size 5 core x 2.5 sq.mm. at PAT MCC module to motor push button station with suitable lugs and crimping.
Jointing of armoured cable of size 3.5 cores x 300 sq.mm. using heat srinkable cable jointing kit
Jointing of armoured cable of size 3 cores x 185 sq.mm. using heat srinkable cable jointing kit
Jointing of armoured cable of size 3.5 cores x 120 sq.mm. using heat srinkable cable jointing kit
Excavation and back filling of cable trench for laying power/ earthing cables/ cable trench of not less than 300 mm width and 600 mm depth (0.6 meter depth from ground level)
Shifting of existing PAT MCC to temporary shed. The scope of work includes dismandling MCC and all incoming/outgoing cables and shifting to nearest temporary shed./reassembling/fixing the MCC and providing 1 number of incoming cable of size 3.5 cores x 400 sq.mm. and 5 numbers of out going power cables (2 no.s of 3 cores x 50 sq.mm., 2 no.s of 3 cores x 35 sq.mm., 1 no.s of 3.5 cores x 185 sq.mm.) and 4 numbers of control cables (5 cores x 2.5 sq.mm.) in newly fabricated cable tray/trench with suitable single compression gland.
HASSAN MM
PAREETH V V
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_816209.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .