Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹14.6 L+₹1.2 L (9.09%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | - | Rejected-Technical Tender Fees not Deposited |
| Sl No | Description | Qty | Unit | NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER L2 | M/s Kakul Traders L1 |
|---|---|---|---|---|---|
| 1.00Safe loading carriage including unloading & proper stacking of following store materials from any Electy.Store of Lucknow Zone to 33/11 KV S/S's EDC Gola (work site). | |||||
| 2.00 | Cost of 33 KV line Isolator | 1 | No. | 550 ₹550 | 500 ₹500 Lowest |
| 3.00 | Cost of 33 KV Bus Isolator | 2 | No. | 550 ₹1,100 | 500 ₹1,000 Lowest |
| 4.00 | Cost of Post Insulator | 6 | No. | 550 ₹3,300 | 500 ₹3,000 Lowest |
| 5.00 | Cost of 33 KV Lightening Arrester | 15 | No. | 550 ₹8,250 | 500 ₹7,500 Lowest |
| 6.00 | Cost of 33 KV VCB 800 Amp., 750 MVA | 9 | No. | 5,100 ₹45,900 | 5,000 ₹45,000 Lowest |
| 7.00 | Cost of 33 KV CT 400/200/1 Amp. | 3 | No. | 550 ₹1,650 | 500 ₹1,500 Lowest |
| 8.00 | Cost of 33 KV CT 200/100/1 Amp. | 9 | No. | 550 ₹4,950 | 500 ₹4,500 Lowest |
| 9.00 | Cost of 33 KV Double T/F Control Pannel with structure. | 2 | No. | 5,100 ₹10,200 | 5,000 ₹10,000 Lowest |
| 10.00 | Cost of 33 KV Single T/F Control Pannel with structure. | 2 | No. | 5,100 ₹10,200 | 5,000 ₹10,000 Lowest |
Tender Value
₹13.4 L
EMD Value
₹13,430
Closing Date
19 Sept 2025, 12:00 pmClosed
SE EWCL
MVVNL, TIPE IV/3, TRANSMISSION STAF COLONY, DEVA ROAD, CHINHAT, Lucknow
Replacement of Damaged 33 KV Isolator CT VCB and Control Panel at Various Substations in EDC Gola at Distt Lakhimpur Under Business Plan 2025 26
2025_MVVNL_1072481_1
19/EWCL/2025-26
Open Tender
Electrical Works
Item Wise
90 days
LAKHIMPUR
AS per PQR
2 documents required · 2 mandatory
₹3,540
SE EWCL
₹13,430
16 Oct 2025
8 Sept 2025
19 Sept 2025
8 Sept 2025
19 Sept 2025
8 Sept 2025
Amount
Safe loading carriage including unloading & proper stacking of following store materials from any Electy.Store of Lucknow Zone to 33/11 KV S/S's EDC Gola (work site).
Cost of 33 KV line Isolator
Cost of 33 KV Bus Isolator
Cost of Post Insulator
Cost of 33 KV Lightening Arrester
Cost of 33 KV VCB 800 Amp., 750 MVA
Cost of 33 KV CT 400/200/1 Amp.
Cost of 33 KV CT 200/100/1 Amp.
Cost of 33 KV Double T/F Control Pannel with structure.
Cost of 33 KV Single T/F Control Pannel with structure.
MS Channel 125x65, 3.2Mtr. Long 1,2,3,4 No Pieces for Top channel. 13.10 Kg/Mtr.+wastage.
MS Angles 75x75x8, 2.6mtr long, total 5.2 @ 8.9 Kg/Mtr.
Cost of ACSR Panther Conductor
33 KV Polymeric Pin Insulator With Nut & Washer
Fabrication, Errection & Grouting of Substation Structure:
Isolator Structure: Fabrication of Isolator Structure 3.5 mtr in height as per Drg. digging of two no. pits of size 1.075x0.9x0.3 mtr. providing Stone Pad at the bottom of the pit and grouting of two legs of the isolator structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the isolator structure shall be properly finished with smoothing of edges.
Lightening Arrestor, P.I. & CT Structure : Fabrication of Lightening Arrestor, P.I. & CT Structure 3.5 mtr. in height as per Drg. digging of two no pits of size 1.075x0.9x0.3 mtr. providing stone pad at the bottom of the pit and grouting of two legs of the Structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the structure shall be properly finished with smoothing of edges.
Plinth of VCB : Construction of Plinth of size 2.0 mtrx1.5mtrx0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:3:6 (cement, find sand & brick ballast) 1st class brick work in cement mortor ratio 1:4:8 (cement, coarse sand and stone grit of 20mm gauge).
Boring Type Earthing : Earthing for power T/F by way of boring and lowering of 40mm dia, 2.9 mm thick GI Pipe B class from ground upto the water level (minimum 60 feet deep) as per standard practice as per RESPO/REC Drg with making of earth pit of 300x300 mm & 1 feet deep with Cover. (All materials to be provided by Contractor).
Chemical Type Earthing : Earthing for power T/F by way of boring and lowering of 40mm dia, 2.9 mm thick GI Pipe B class from ground upto the water level (minimum 10 feet deep) and Connected To Chemical Bag as per standard practice as per RESPO/REC Drg with making of earth pit of 300x300 mm & 1 feet deep with Cover. (All materials to be provided by Contractor).
Stringing, Jumpering and Connections : Stringing and Stranthing of Existing 33KV Bus Bar using of ACSR Panther Conductor and making vertical/Horizontal jumper connection and connecting all the equipments with each other through PG clamps/clamps. Work includes all the jump ring from terminal gantry to Bus Bar and from Bus Bar to Transformer (1no. T/f bay's) (All decentralised materials to be provided by Contractor).
Shifting carefully and installation of 33KV Single/Double Transformer Control Panel in Control Room including fixing, bolting & grouting of above as per requared and testing, commisioning satisfaction of site incharge.
Installation of Isolators: Assembling and installation of line/ bus isolator on the isolator structure adjusting of opening mechanis in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat by G.I. erth strip 50x6mm for proper flexing if required.
Installation of P.I. : Assembling, installation & mounting of 3 No. Post insulator on the P.I. Structure/complete with making earth connections (separate) and line connections. The work includes fabrication for fixing if required.
Installation of CT: Installation of 3 No.(1 set) CT on the CT Structure along with CT Junction Box. The work includes fabrication for proper fixing of C.T. If required and proper commissioning & testing.
Installation of VCB: Installation of 33KV VCB complete work including commissioning & testing.
Installation of Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A.on the L.A Structure/complete with making earth connections (separate) with GI Strip 50x6mm. The work includes fabrication for fixing if required. (All decentralised materials to be provided by Contractor).
Painting of all structures and equipments with good quality ISI Mark one coat of red oxide primer & two coats of Aluminium Paint. (All materials to be provided by Contractor).
Supply and laying of following size Good Quality Armoured Copper Control Cable through underground/cable trench/trenching SGR interlinking through proper connections to T/F Control panel/protection board/Battery and Battery Charger/Bunch joints, Relay 33/11KV T/F junction Box/33KV VCB, CTs etc. as per site conditions:
2x2.5 Sq.mm
4x2.5 Sq.mm
6x2.5 Sq.mm
Control Cable Tray
Repair and Whole Maintenance of Existing 33 KV VCB
Supply and Installation of 24 Volt Battery and it charger with connections to existing control circuit complete in all respects.
Repair and Whole Maintenance of Existing 33 KV CRP
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER (BID ID -5545251)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
Tender Document • 6.23 MB
SBD19.pdf
Tender Document • 0.97 MB
TenderFormSchedule.pdf
Tender Document • 0.27 MB
BOQ_1957234.xls
BOQ • 25.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .