Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹45.1 L
Closing Date
8 May 2026, 3:00 pmClosed
Yes (up to 3 members)
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
16 conditions · 5 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Bid Capacity:- The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of GCC 2022 with all correction slip.
Joint Venture:- Clause no. 17 of GCC-2022 with all correction slip with their qualifying criteria will be applicable in case of Joint Venture(JV).
Partnership firm:- Clause no. 18 of GCC-2022 with all correction slip with their qualifying criteria will be applicable in case of partnership firm
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar work means:- (i)Indoor work involving supply, installation, testing & commissioning of Electronic Interlocking/RRI/PI (OR) (ii) Both Indoor and Outdoor works involving supply, installation, testing & commissioning of Electronic Interlocking/RRI/PI (OR) (iii) Indoor & Outdoor works for IBS/ABS/LC Interlocking/Yard remodeling work involving installation or alteration to Electronic Interlocking/RRI/PI. NOTE : (i) The successful bidder shall submit an undertaking from RDSO approved EI OEM, before the supply of material, to confirm compliance with extant RDSO guidelines and to meet contract specific requirements. Note for Technical Eligibility Criteria :- Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
S&T cable clearance in the yard to facilitate the engineering earthwork , yard remodeling work and Modification/Alteration in Distributed Electronic Interlocking (M/s Hitachi STS (formerly known as Ansaldo STS) make) at Madwarani station and new Centralized Electronic Interlocking at Saragbundia and Auto signaling work (EI based) in connection with 3rd & 4th line work between SRBA-MWRN in CPH-GAD section in Bilaspur Division of SEC Railway
762-SRBA-MWRN
762-SRBA-MWRN
Open
Works - General
12 Months
Bilaspur, Chhattisgarh
₹0
₹45.1 L
8 May 2026
15 Apr 2026
24 Apr 2026
917 items across 17 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,37,72,150 | ||
| — | 2.00 | — | — | ||
| Dismantling of the following: - ix) Operating cum indication Panel. | — | — | — | 4,830 | |
| — | 12.00 | — | — | ||
| Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (i) all soils including soft rocky area. (b) Depth 1.0 Mtr. & width 0.3 Mtr. | — | — | — | 9,19,080 | |
| — | 500.00 | — | — | ||
| Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting. (a) Chase cutting and smoothening of inside surface of sizes 0.08 m deep and 0.17 m width at platform and cemented floor area. | — | — | — | 57,500 | |
| — | 7.00 | — | — | ||
| Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting. (b) Cutting the masonary wall to the depth of 0.25m to 0.75m at the entry of room placing of flexible HDPE pipe or G.I.Pipe (including supply) of suitable size as per drawing No. RE/S&T/ALD/SK/161/81. | — | — | — | 4,074 | |
| — | 2000.00 | — | — | ||
| Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (iii) Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI/HDPE pipe . (b) GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters). | — | — | — | 44,92,000 | |
| — | 150.00 | — | — | ||
| Laying of Signalling Cable/Power/Quad cable / PIJF cable in the excavated trench to Drg.No:CON/SK/T/5.Transportation, supply of 'U' clamps and anchoring of cable at every 10 Mtrs with 'U' clamp to Drg.No:CSTE/C/Cable/81 including back filling with excavated earth and ramming of trenches after cable laying. | — | — | — | 25,11,000 | |
| — | 2.00 | — | — | ||
| Laying of Power cable in the same excavated trench to Drg.No:CON/SK/T/5.Transportation, supply of 'U' clamps and anchoring of cable at every 10 Mtrs with 'U' clamp to Drg.No:CSTE/C/Cable/81. Transportation, supply and placement of 2nd class bricks in the trench length wise between power cable & other signalling/quad cable in the same trench all along the trench (4.5 bricks approx per Mtr.) including back filling with excavated earth and ramming of trenches after cable laying. | — | — | — | 51,052 | |
| — | 500.00 | — | — | ||
| Laying and Fixing of galvanised iron pipe (GI Pipe) with threaded collars (for jointing pipe) of 80 mm nominal dia Spec.No.IS-1239 medium grade, on bridges, culverts, drains including supply and transportation of GI pipes and all other materials required for fixing the pipe to Drg.No.Con/SK/T/2 and drawing of Signal/Power/Quad cables inside the pipe with masonary works over the entire length of the bridge and at entry and exit of the culvert and curing for 72 hrs, drilling of holes on the pipe at 10 cm apart to be clamped 2 Mtrs apart on culvert, for the Signalling, quad, power cable. NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 7 as mentioned above till commissioned. | — | — | — | 3,80,500 | |
| — | 300.00 | — | — | ||
| Laying of RCC pipe including supply of required quantity at site with collars (for jointing pipe) 150 mm nominal dia to Spec.No:IS-458 in excavated trench and laying of Signalling/ Power cable/PIJF cable/ Quad cables/HDPE pipe through RCC pipe. Power cable shall be laid in the same trench alongwith signalling/Quad cables but in a separate pipe RCC pipe at track/pucca road/ Platform crossing/ level crossing gate etc. NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 7 as mentioned above till commissioned. | — | — | — | 2,32,500 | |
| — | 200.00 | — | — | ||
| Laying of half round RCC hume pipe with 150 mm dia & 1 mtr long including supply at site on single/multiple cable laid in the trench . NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 7 as mentioned above till commissioned. | — | — | — | 50,800 | |
| — | 2.00 | — | — | ||
| Laying of second class bricks including supply of required quantity at site on single/multiple cable laid in the trench (Approx 9 bricks per mtr). NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 7 as mentioned above till commissioned. | — | — | — | 65,206 | |
| — | 10.00 | — | — | ||
| Shifting of cables in roll with or without wooden drums from other than nominated consignee depot and meggering before loading and after laying, and recording the values in cable insulation register along with representative of Railways. (here job unit stands for drum/roll) | — | — | — | 12,820 | |
| — | 140.00 | — | — | ||
| The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus case, fixing o f terninals, f u s e blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case a s required, testing, commissioning including subsequent alterations (if required), bunching o f cables, earthing o f cable, armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. (a) Steel appartus case (Large) to Drg.No. CON/SK/T/8 with 4 Nos. of foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest. NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 23,89,380 | |
| — | 10.00 | — | — | ||
| The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus case, fixing o f terninals, f u s e blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case a s required, testing, commissioning including subsequent alterations (if required), bunching o f cables, earthing o f cable, armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. Steel appartus case (half) with 4 Nos. of SS foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest. NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 85,340 | |
| — | 2.00 | — | — | ||
| The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus case, fixing o f terninals, f u s e blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case a s required, testing, commissioning including subsequent alterations (if required), bunching o f cables, earthing o f cable, armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. (c)Steel appartus case (Quarter) to Drg.No. RE/S&T/Sig./Tender/SK / 5A/91 with 4 Nos. of SS foundation bolts of size 20mm x 300mm or latest. NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 8,532 | |
| — | 20.00 | — | — | ||
| (a) Alteration/ Modifications in the existing location boxes, fixing of equipments, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 50,960 | |
| — | 20.00 | — | — | ||
| (b) Shifting of existing location boxes to facilitate earthwork of Engg./Con. This includes filling with sand and plastering inside location boxes. | — | — | — | 71,600 | |
| — | 10.00 | — | — | ||
| Cement Concrete of proportion 1:3:6 with graded aggregate of size 25mm. and below. | — | — | — | 29,430 | |
| — | 200.00 | — | — | ||
| Excavation o f earth pit, transportation, placing and fixing of earth electrode with construction o f cement encloser t o Drg.No.CON/SK/T/9 and CON/SK/T/9A and drawal of GI wire wrapped on MS strip (35 x 6 mm) from earth electrode to all signalling equipments, including fixing and soldering of lugs at both end of the wire. | — | — | — | 3,88,200 | |
| — | 8.00 | — | — | ||
| Installation of signal posts for Multiple Aspect Colour Light Signals complete with signal units, bases, LED unit, fixing and wiring of current transformers of LED units, ladders & other fittings, excavation of pit, casting of cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of the signal/signal post with necessary earthed screen protection arrangement, including drawing of cable through signal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply and fixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light Signal Post drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. (i) 2 ASPECT Note: Payment can be released in a part for the above said works after completion of- (i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting,sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 1,39,024 | |
| — | 21.00 | — | — | ||
| Installation of signal posts for Multiple Aspect Colour Light Signals complete with signal units, bases, LED unit, fixing and wiring of current transformers of LED units, ladders & other fittings, excavation of pit, casting of cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of the signal/signal post with necessary earthed screen protection arrangement, including drawing of cable through signal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply and fixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light Signal Post drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. (ii) 3 ASPECT/4 ASPECT Note: Payment can be released in a part for the above said works after completion of- (i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting,sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 4,10,571 | |
| — | 34.00 | — | — | ||
| Fixing of calling-on signals/dependent shunt signals with enameled markers including drawing of cable through the signal post, termination of cables, wiring, fixing of calling- on/dependent shunt signal legend board, LED, two coat painting and lettering, testing and commissioning as required. Note: Payment can be released in a part for the above said works after completion of- (i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting,sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 1,57,386 | |
| — | 7.00 | — | — | ||
| Installation, testing and commissioning of Position Light shunt signal (Independent), posts complete with lamps/LED lamps, LED units, Bases and other fittings, excavation o f pit, casting o f cement concrete foundation, fixing of complete fittings o f signal, LED lamps, current regulator including foundation bolts, washers, nuts, termination of cables, wiring, painting and lettering as required. NOTE:- The foundation for position light shunt signal Drg. No. Con/SK/T/13 and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA-110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. Note: Payment can be released in a part for the above said works after completion of- (i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting,sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | — | — | — | 26,992 | |
| — | 11.00 | — | — | ||
| Fixing, cable drawing and termination, wiring, painting, lettering, testing and commissioning of Junction type Route indicator complete along with lamp/LED unit (i) 1/2 Way | — | — | — | 23,210 | |
| — | 500.00 | — | — | ||
| Physical tracing and opening/locating of existing working cables by precession digging for diversion of cables in connection with cable clearance for engineering earth work without interfering the circuits as per the advice of Railway site engineer. | — | — | — | 1,20,500 | |
| — | 5.00 | — | — | ||
| Alteration/modification, testing, commissioning, t w o c o a t painting, lettering o f t h e existing 2 Aspect/3 Aspect/4 aspect signals/shunt signals/calling on signal/ LC gate to suit the circuit per approved wiring diagram including fixing of LED/Singal lamps and their wiring. | — | — | — | 6,370 | |
| — | 9.00 | — | — | ||
| (a) Supply & Erection alongwith casting of foundation of Stop board /Sighting board/SLB/BSLB/legend board as per approved drawings. | — | — | — | 45,846 | |
| — | 55.00 | — | — | ||
| (b) Supply of retro reflective signal/shunt signal enameled number legend board of size- 300mm X 200mm X 3mm (minimum) made up of alluminium composite - 4 panel (ACP) with white back ground and alphabets/numbers in black along with fixing clamps. Inspection by Rep. of Railway Engineer. | — | — | — | 16,940 | |
| — | 55.00 | — | — | ||
| (c) Installation of retro reflective signal/shunt signal enameled number legend board . | — | — | — | 4,235 | |
| — | 6.00 | — | — | ||
| Excavation & casting of pedestal foundation for left/right hand boom of lifting barriers. | — | — | — | 56,562 | |
| — | 6.00 | — | — | ||
| Excavation & casting of foundation for stop post. | — | — | — | 8,718 | |
| — | 3.00 | — | — | ||
| Erection and commissioning o f Lifting Barrier assembly complete including boom support, positive boom locking device, Emergency crank handle attechment, Timer unit to adjust the time for operating the barrier, Fixing of Hooters/Flashers on either side of gate barriers, 1 (one) control panel, weather proof painting, lettering, Neccessary MS weight for balancing the booms, etc. | — | — | — | 53,736 | |
| — | 15.00 | — | — | ||
| Dismantling of the following: - i) Signal posts/BSLB/SLB/Stop Board. | — | — | — | 3,480 | |
| — | 100.00 | — | — | ||
| Dismantling of the following: - ii) Steel apparatus case with fittings. | — | — | — | 23,200 | |
| — | 20.00 | — | — | ||
| Dismantling of the following: - iii) Relay racks with all fittings, battery racks complete, Equipment rack complete, SM's slide. | — | — | — | 7,200 | |
| — | 5.00 | — | — | ||
| Dismantling of the following: - iv) Battery charger, Battery set etc.TLBI, DLBI and other Misc. equipments. | — | — | — | 1,145 | |
| — | 3.00 | — | — | ||
| Dismantling of the following: - vi) Lifting barrier complete. | — | — | — | 10,869 | |
| — | 80.00 | — | — | ||
| Dismantling of the following: - vii) TLJB/Point JB | — | — | — | 4,800 | |
| — | 10.00 | — | — | ||
| Dismantling of the following: - viii) Electric Point Machine | — | — | — | 6,030 | |
| — | 100.00 | — | — | ||
| Dismantling of the following: - x) Location Foundation(By hydraulic breaker) | — | — | — | 1,08,700 | |
| — | 25.00 | — | — | ||
| Dismantling of the following: - xi) Signal Foundation(upto ground level by hydraulic breaker). | — | — | — | 54,350 | |
| — | 3000.00 | — | — | ||
| Collecting, stacking with deployment of Man power, Hydra etc for Loading/ Unloading and Transportation of Materials (Fresh/Released/ Unused) from (i) work site to GSD/Raipur, (ii) work site to the stotre of SSE(SIG)/CON,(iii) any store depot to any other store depot over Indian railways as decided by Railway Administation by suitable Trucks and stacking properly. (here job stands for Ton-Km) | — | — | — | 1,14,000 | |
| — | 2.00 | — | — | ||
| — | 31.00 | — | — | ||
| — | 15.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 3.00 | — | — | ||
| — | 10.00 | — | — | ||
| Installation and Fixing of "E" type lock along with Welding Work . | — | — | — | 7,040 | |
| — | 20.00 | — | — | ||
| Deployment of Prokline/ Hydra operation at site for exposing the burried cables or relocation the Location Box/ Signal Post with foundation as per the advice of Railway site engineer. | — | — | — | 12,060 | |
| — | 300.00 | — | — | ||
| — | 200.00 | — | — | ||
| Fixing of concrete cable route marker at 30-40 meter and at diversion point including supply & transportation of cable route marker at site. Detail size & fixing of cable route marker should be followed as per drawing no. SDO/Cable laying/020. | — | — | — | 83,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
MWRN3RD4THLINESIPWITHAUTO_version01ondate17-12-24.pdf
ATTACHMENT
SARAGBUNDIASIPFORAUTOSIGNALLINGONADDITIONALLINE_V1_APPROVE_P9.pdf
ATTACHMENT
3.Generalinstructionforschedule752.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf correction
ATTACHMENT
GCC-Apr-2022_compressed.pdf
ATTACHMENT
GCC-2022-Correction-Slip-I.pdf
ATTACHMENT
GCC-2022-Correction-Slip-II.pdf
ATTACHMENT
GCC-2022-Correction-Slip-III_compressed.pdf
ATTACHMENT
GCC-2022-Correction-Slip-IV.pdf
ATTACHMENT
GCC-2022-Correction-Slip-V.pdf
ATTACHMENT
GCC-2022-Correction-Slip-VI.pdf
ATTACHMENT
GCC-2022-Correction-Slip-VII.pdf
ATTACHMENT
GCC-2022-Correction-Slip-VIII.pdf
ATTACHMENT
GCC-2022-Correction-Slip-IX.pdf
ATTACHMENT
GCC-2022-Correction-Slip-X.pdf
ATTACHMENT
procedureofdigginginvicnityofcable.pdf
ATTACHMENT
scc_1.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .