| 1 | L1₹33.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹35.4 L+₹67,249.75 (1.94%)Rejected-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹36.9 L+₹2.1 L (6.12%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L3 | Rejected-Finance Being other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical not enlisted in requisite category |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
30 Oct 2023, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
SPL REPAIR TO BLDG Nos T223 OF SUPPLY POINT AND P53 OF MULE SHED OF KUMAON SCOUTS AND MISCELLANEOUS WORKS AT MH SUB STN AT MIL STN DHARCHULA
2023_MES_621266_1
8557/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Dharchula
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹88,000
Yes
26 Dec 2023
30 Sept 2023
6 Nov 2023
30 Sept 2023
30 Oct 2023
16 Oct 2023
3 Oct 2023 - 9 Oct 2023
Amount
DESCRIPTION OF ITEMS
Demolition of cement concrete in ground floor, paving nexc 15cm thick (below or above GL) complete all as specified and directed.
Demolition of precast cement concrete block /brick wall masonry built in cement mortar complete all specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided, complete all as specified & directed.
Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed.
Removing building materials etc. to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
M &L Glazed ceramic tiles colured in vertical surface 450X 300(7-8mm) thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 on fair face of brick work or concrete surfaces as backing for tiles complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6, type C-2, as in Plinth protection etc finished even & smooth without using extra cement complete all as specified & directed.
M&L for cement concrete 100 mm thick type B-1 (1:2:4) using 20 mm graded agg as in floor etc. finishing cement concrete surface even and smooth using extra cement complete all as specified and directed.
M&L for cement concrete 100 mm thick type B-2 (1:2:4) using 40 mm graded agg as in ramp, path etc. finishing cement concrete even and smooth without using extra cement complete all as specified and directed.
Forming 12mm thick expansion joint filled with pre formed bituminus filler and top 30mm primed and sealed with sealing compound grade B for 100mm thickness of concrete complete all as specified and directed.
M&L for brick work with sub class B Brick straight curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L, cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as in surface channel or drain complete all as specified and directed.
Extra for forming fair finished drains or channel 30 Cm inner girth in cement concrete , using extra cement including form, moulds, mitred / stopped ends etc complete as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto as above complete all as specified and directed.
Supply & Fix mild steel work in framed work such as grills, gratings, framed guard bars, ladders etc. with ends of bars shouldered and / or riveted or forged into spikes, and similar work confirming to Fe 290.Gde E-165 complete all as specified and directed.
M&L for precast cement concrete type B1 1:2:4 (Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainge cover set in cement mortar 1:6 including necessary formwok complete all as specified and directed.
M&L TMT bars, 6 to 8mm, cut to length, bent to shape required including cranking,bending spirally for hooping for column, hooking ends and binding with and incl MS wire(annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L rendering 12mm thick cement plaster on internal surface of wall in CM (1:6) complete all as specified and directed.
M&L three coats of white wash on walls including preparation of new plastered surface complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with WPC (WPC to be paid separately) as per manufacturer's instructions, finished even and fair complete all as specified and as directed.
Supply only liquid waterproofing compound ISI marked complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M&L 5mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces in ceiling complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of ceilings or wall surfaces and applying two coats of white wash complete all as specified and directed.
S&F 15 mm bore in repair GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking down old pipe, complete all as specified and directed.
-ditto- as item no. 28 above but 20 mm bore complete all as specified and directed.
S&F in repair triple layered 1000 Ltr rotational moulded polyethylene water storage tanks ( cylinderical vertical with closed top) hoisted & fixed in position including taking down old tank complete all as specified and directed.
S&F Ball valves 20mm dia., high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as spfd & directed.
S&F in repair 15 mm bore bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide, zinc chrome primer to new steel surfaces of any description exc 10 cm girth or width including prepration of surfaces complete all as specified and directed.
Dismantling plain or corrugated steel sheeting ,any gauge,thickness,including Nainital or similar pattern roof coverings and wall cladding complete all as specified.
Dismantling wall and ceiling boards (fibre,pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
Dismantling timber scantling 40sq.cm and over in section in any position in framed work complete all as specified and directed.
Dismantling timber in fillets,rails posts ,rafters,purlins etc under 40 Sq.cm in section all as specified and directed.
Taking down chowkats or frames exc 1.5sqm but N.exc 4 Sqcm each with shutter(without taking off shutters from the frame)all as specified and directed.
Taking down chowkats or frames n exc 1.5 sqm each with shutter(without taking of shutters from the frame)all as specified and directed.
Roughening surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc.complete all as specified and directed.
M&L for Joint free non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm and not exceeding 0.18 sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles with as in floor, finished the surface rough to receive tiles complete all as spfd & directed.
Ditto all same as item No 41 above but for skirtings as including 10mm thick rendering in cement mortar 1:4 on fair face of brick work or concrete surfaces as backing for tiles.all as specified and directed
M&L for providing cement concrete type B1 1:2:4 (20mmgraded stone aggregate) as in copings, apex stone including weathering ,slightly rounded or chamfered angles and throating as,directed and specified.
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for rendering 15mm thick cement plaster on external surface of wall in CM (1:4) all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with or without glazing bars dovetailed or welded complete all as specified and directed.
M&L for 2nd class hard wood as in scantling clean sawn framed & fixed as in wall & ceiling wks, complete all spfd & directed.
M&L for II nd class hard wood plain fillets square or rectangular in section clean sawn secured with nails sectional area exc 13 sqcm and n.exc 25 sqcm complete all as specified and directed.
M&L II nd class hard wood plain fillets square or rectangular in section cleansawn but bullnosed chamfared or rounded on one edge or face sectional area exc 6 sqcm and nexc 13 sqcm secured in nails complete all as specified and directed.
M&L for one coat of creasote oil to wooden surfaces new or old of any description including prepration of surfaces complete all as specified and directed.
M&L for 6mm thick Plywood, grade BWR, type BB, fixed in wall & ceiling cladding with screws to timber frame work complete all as sfd and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete drilled for fixing of steel sheeting or other coverings.etc fastening and fixing complete FE-410W Gde E-250 Qyality-A complete all as sfd and directed.
M&L for 35 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both side, face of door be lipping with 6 mm teak wood lipping, complete all as specified and as directed.
S&F 35 mm thick 2nd class hardwood as in Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as spfd & directed.
S & F of 3mm thick plain sheet glass, ordinary quality and glazing with oil putty or fixed with beads in square in each pane complete all as specified and directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in Door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 300mm long complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue,anodised with hard drown steel spring, fixed in floors 150 mm long all as specified and directed.
M&L for two coat of synthtic enamel paint over a coat of pink primer to new wooden surface of any description exc 10 cm girth or width including prepration of surfaces complete all as specified and directed
M&L for one coat of synthtic enamel paint to old steel surface of any description exc 10 cm girth or width including prepration of surfaces complete all as specified and directed
S&F 100mm long butt hinges,medium weight cold rolled mild steel and fixed to frame all as specified and directed.
S&F 250mm mild steel sliding door bolts,plate type ,stove enamelled black ,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate all as specified and directed.
S&F 125mm mild steel pressed handle, oval type stove enamelled black all as specified and directed.
S&F 150mm long mild steel barrel tower bolts stove enamelled black with bright bolt and fixed to frame all as specified and directed.
S&F 200mm long mild steel barrel tower bolts stove enamelled black with bright bolt and fixed to frame all as specified and directed.
S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fix with self tapping screw all as specified and directed.
S&F pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fix with self tapping screw all as specified and directed.
E/M Items :
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc all as specified and directed
Dismantling house service brackets, any type from existing position complete all as specified and directed.
M&L point wiring with 1.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in open PVC surface conduit 20mm or higher dia, complete with all accessories /fitting and Ist class hard wood (Shisham) terminal switch board of suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washer including unsheathed single core PVC insulated cable green in colour 1.5 Sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly complete all as specified and directed for One light point/Fan point/bell point controlled by one way switch of 5/6 Amps complete all as specified and directed.
~Ditto~ all as per item No 72 above but for one 3/5 pin socket outlet point on same board controlled by one way switch of 5 Amps complete all as specified and directed.
~Ditto~ all as per item No 72 above but for one 3/5 pin socket outlet point on independent board controlled by one way switch of 5 Amps complete all as specified and directed.
M & L point wiring with 2.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC conduit not less than 20mm dia, in concealed/open surface type complete with all accessories /fitting and Ist class hard wood (Shisham) terminal switch board of suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washer including unsheathed single core PVC insulated cable green in colour 2.5 Sqmm multistranded copper conductor cable as earth wire and connecting to earth dolly complete all as specified and directed for 3/5 pin, 15/16 Amps power socket controlled by one, one way switch of 15/16 Amps complete all as specified and directed.
M&L point wiring with 1.5 sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor FRLS cable drawn in existing PVC conduit, in concealed surface type complete with all accessories /fitting and MS terminal switch board of given size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly complete all as specified and directed for one light point/Fan point controlled by one way switch of 5/6 Amps.
~Ditto~ all as per item No 76 above but for one 3/5 pin socket outlet point on same board controlled by one way switch of 5 Amps complete all as specified and directed.
M&L power point wiring with 2.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable drawn in existing PVC conduit, in concealed surface type complete with all accessories /fitting and MS terminal switch board of suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washers including unsheathed single core PVC insulated cable green in colour 2.5 Sqmm multistranded copper conductor cable as earth wire and connecting to earth dolly complete all as specified and directed.
M&L point wiring with 1.5 sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor FRLS cable drawn in PVC conduit, in concealed conduit / surface type complete with all accessories /fitting and MS terminal switch board of given size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly complete all as specified and directed for one light point/Fan point/bell point controlled by one way switch of 5/6 Amps complete all as specified and directed.
S&F switch piano flush button single pole one way 5 Amps complete all as specified and directed.
S&F switch piano flush button single pole one way 15Amps complete all as specified and directed.
S&F socket out let 3 pin 5/6 Amps flush type complete all as specified and directed.
S&F socket out let two in one 3 pin 5/6 Amps and 3 pin 15/16 Amps, flush type, non shutters, non interlocking complete all as specified and directed.
S&F Ceiling rose, surface bakelite, AC, 60x30mm, 3 terminals complete all as specified and directed.
S&F lamp holder PVC/poly carbonated type with back plate suitable for pendants /angular /batten fittings complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
S&F sheet metal enclosure for DB SPN 8 way with 200 Amp rated bus bar 240 Volts, double door suitable for housing MCBs and isolators complete all as specified and directed.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F 32 Amp rating 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral , in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing LED lights fitting 1x 18/20W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S&F LED bulb 12 watts, 220V complete all as specified and directed.
M&L for 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with an inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 M apart including 4mm dia GI suspension wire one twin core flat or circular stranded conductor of size 10 Sqmm complete all as specified and directed.
M&L for house service bracket (hook type complete with 3.0 mtr long GI Pipe 40mm dia med grade, two nos 90 degree bend, clamps, nuts and bolts, washers, MS hooks and stay or guy complete all as specified and directed.
S&F in replacement of 1x35 watt LED building security light fitting, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including GI bracket made out of 1.5 mtr GI pipe bent to shape light grade of 40mm dia, bracket mounting clamps nut bolts etc and making electric connection with 3 core 1.5 sqmm PVC insulated copper conductore cable complete all as specified and directed.
Labour only for cutting chases in stone concrete, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metres below normal ground level, conneted to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, cheek nuts and washers of galvanised or iron protected by 15 mm bore GI pipe (medium grade) and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 6Cm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifitting made out of 8 mm dia MS bar, funnle, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR part-I, 2009.
Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 3-corex95 sqmm (insulated phase conductors) + 1-corex70 sqmm (bare neutral messanger conductor) ISI marked complete all as specified and directed.
Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 3-corex50 sqmm (insulated phase conductors) + 1-corex35 sqmm (bare neutral messanger conductor) ISI marked complete all as specified and directed.
Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 3-corex35 sqmm (insulated phase conductors) + 1-corex25 sqmm (bare neutral messanger conductor) ISI marked complete all as specified and directed.
Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 1-corex16 sqmm (insulated phase conductors) + 1-corex16 sqmm (insulated neutral messanger conductor) ISI marked complete all as specified and directed.
Supply and fix insulation piercing connectors (IPC) for main cable of 16-50 sqmm with taps ranging from 4-50 sqmm IPC type 002 for distribution/service/street light connections complete all as specified and directed.
Supply and fix insulation piercing connectors (IPC) for main cable of 70-95 sqmm with taps ranging from 4-50 sqmm IPC type 002 for distribution connections complete all as specified and directed.
Supply and fix suspension clamp suitable for 16-70 sqmm size neutral conductor with eye hook complete all as specified and directed. Note: MS Clamps incl nut-bolt & washers shall be measured seperately.
Supply and fix anchoring clamp suitable for cable size 16-50 sqmm with Al alloy body complete all as specified and directed. Note: MS Clamps incl nut-bolt & washers shall be measured seperately.
Supply and fix anchoring clamp suitable for cable size 70 sqmm with Al alloy body complete all as specified and directed. Note: MS Clamps incl nut-bolt & washers shall be measured seperately.
Supply and fix three phase Distribution box with spring loaded busbar connection for 2 Nos outgoing cable connections including Al. alloy bracket, stainless steel strap, buckles, eye hook incl nuts bolts and washers complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by 40 mm bore GI pipe (medium grade) all as shown in electrical plate No. 3, connected to earthing test point all as specified or indicated including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 6Cm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifitting made out of 8 mm dia MS bar, funnle, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR part-I, 2009.
Supply & fixing stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 20 mm dia with nuts including GI bow turn buckle etc., all as per Electrical plate No 1 or SSR -2009 Part I complete all as specified and as directed. Note. Loop type insulator, stay clamps, excavation, PCC will be paid seperately under relevant items of Sch A
M&L for loop type insulators vitreous porcelain white, brown or green large size with overall dimensions 65x90 mm clearance of hole 25.5 mm complete all as specified and directed.
Excavation in trenches/holes in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation/for poles etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road incl nut,bolts and clamps for fixing to pole etc. complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using 40mm graded stone aggregate in foundation of pole and stay as in mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in plinth block of pole and stay including necessary form work complete all as specified and directed.
M & L for Sand cushioningng (dry sand) to under ground cable for cable protection provided with layers 8cm thick before laying and 15cm thick after laying the cable and punned down to 10 cm thickness complete all as specified and directed. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR Part-I
Supply and laying sub class B bricks old size for protection of cables laid lengthwise perpendicular to the axis of cable, adjecent to each other complete all as specified and directed.
S&F steel tubular swaged pole complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 09 mtr long, all as specified and shown on drawings including the followings: (a) Excavation in trenches 1.20 x 0.60 mtr & 1.65 Mtr deep for pole foundation & getting out in any type soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (b) PCC (1:4:8) type D2 using 40mm graded stone aggregate as in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (c) PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation 600mm x 600mm x 1500 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (d) PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of size 300x300x300 including necessary form work
(e) Painting of poles externally with one coat of bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over one coat of red oxide primer including preparation of surface. (f) The portion above coping shall be painted in alternation bands of black and yellow colour (each band of 30 cm wide) by two coats of super enameled paint upto 1.5m height.
S&F steel tubular swaged pole complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55, 11 mtr long, all as specified and shown on drawings including the followings: (a) Excavation in trenches 1.20 x 0.60 mtr & 1.95 Mtr deep for pole foundation & getting out in any type soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (b) PCC (1:4:8) type D2 using 40mm graded stone aggregate as in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (c) PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation 600mm x 600mm x 1800 mm for concrete encasing the pole up to GL all as specified and directed. (d) PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of size 300x300x300 including necessary form work
(e) Painting of poles externally with one coat of bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over one coat of red oxide primer including preparation of surface. (f) The portion above coping shall be painted in alternation bands of black and yellow colour (each band of 30 cm wide) by two coats of super enameled paint upto 1.5m height.
M&L steel work in FE-410-S grade for cross arms, bracing, supported, clamps & back plates fabricted from structural steel section including nuts, bolts, washers, welding. Bending cold and hot Drilling hole for bolts, in any size as indicated or directed and inclusive of one primer coat of red oxide primer, one under coat and one finishing coat of paint aluminum grey complete as specified and directed.
Supply, installation, testing & commissioning Street light Timer panel suitable for 220 Volt, Single phase, 2 wire 50 Hz, AC supply system outdoor type, totally enclosed, dust, weather & vermin proof fabricated out of 3.0mm CRCA sheet (outer shall) & 2.0mm inner shell, duly spray painted with powder coated paint, bottom base channel of MS section not less than 30mm x 30mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 3 mm at the rear with 2 Nos earth stud, solid connections from main busbar to switchgears with required size of Aluminium busbars/copper conductor cables and control wiring with minimum 1.5/2.5 sqmm PVC insulated copper conductor wire, cable alleys, cable glands comprising of the following : INCOMING : (a) MCB SPN 220V 32 Amp with breaking capacity 16 KA OUTGOING : (b) MCB SPN 220V 20 Amp with breaking capacity 16 KA -02 Nos (c) 2 Pole power contactor with 1 NO + 1 NC & range 9-30 Amp (d)Time switch FM1 / Quartz Daily 240 VAC Base/DIN mounting
S&F in replacement of MCCB 4 pole, 125 Amp, 16kA, 415 V, 50 Hz thermal adjustable and fixed magnetic setting type complete all as specified and directed.
Supply, laying, testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, served with inner sheathing of PVC tape armoured with galvanised steel wire overall PVC sheathed 1100 volts grade, cross-sectional area 3½ core 70 Sqmm complete including taking up complete all as specified and directed.
Supply, laying, testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, served with inner sheathing of PVC tape armoured with galvanised steel wire overall PVC sheathed 1100 volts grade, cross-sectional area 3½ core 95 Sqmm complete including taking up complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road incl nut,bolts and clamps for fixing to pole etc complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed.
Dismantling insulators incl nut bolts & washers of any type, any size complete all as specified and directed.
Dismantling stay assembly complete all as specified and directed.
Dismantling earth wire or copper conductor, service feeder or distributor span
Dismantling of ACSR or AAC conductors complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 1,45,687.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/s J P Traders
SHAHJEE FRIDGE SERVICE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .