Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC Selected | |
| 2 | L2₹7.1 L+₹190 (0.03%)Rejected-AOC | L2 | Rejected-AOC Selected | |
| 3 | L3₹7.3 L+₹17,612 (2.49%)Rejected-AOC | L3 | Rejected-AOC Selected | |
| 4 | L4₹7.5 L+₹42,086 (5.95%)Rejected-AOC | L4 | Rejected-AOC Selected | |
| 5 | L5₹8.0 L+₹94,655 (13.4%)Rejected-AOC 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L5 | Rejected-AOC Selected |
Tender Value
₹10.8 L
EMD Value
₹21,531
Closing Date
10 Jun 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Providing Electrical Repair/Renovation Work in Vigilance Branch 5-7th Floor at Police Station B.K. Road, New Delhi.
2019_PWD_173351_1
76/EE (E)/PWD DHC and ND/Central /2019-20
Open Tender
Electrical Works
Works
30 days
New Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹21,531
9 Nov 2020
31 May 2019
10 Jun 2019
31 May 2019
10 Jun 2019
31 May 2019
Amount
Supplying & fixing of energy efficient 15 to 18 watts LED down lighter luminaries in the surface including connection, testing etc. as required The Total minimum system efficacy of luminaries should be minimum 80 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required including dismantling alongwith credit for worn out luminaries under buy back arrangement. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
Supplying, installation, testing & commissioning of 20 to 22 watts, 6000K, 1200 mm long energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work on 230 volts, AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying, installation, testing & commissioning of energy efficient LED flood light luminaries of system wattages 90 to 100 complete with accessories on the existing boundary wall including connections with 1.5 sq mm FRLS PVC insulated copper conductor single core cable complete etc as required The LED luminaries should confirm the following technical specifications :- a. Type of LED: High power LEDs Nichia/Osram/Cree/Philips b. driver efficiency >85% c. System Efficacy >100lm/w d. color Index(CRI) Ra>70 e. Color Temperature (CCT) Cool white:5500°-6500°K f. Input Voltage. 140-270V AC g. Frequency Range 50-60Hz h. Power Factor(PF) > 0.95 i. Surge protection = 4.0KV j. Total Harmonic Distortion(THD)< 10% k. Working Environment 0°C to 50°C;10%-90%RH l. Working lifetime: >50000hrs m. IP Rating :- IP: 65/ IP: 66 n. Housing and finish :-epoxy powder coated die cast aluminum housing with elegantly designed heat sink for efficient thermal management and to excellent corrosion resistant, cable gland P49 is provided at cable entry cover & high quality toughned glass.
Supplying, installation, testing & commissioning of LED Post top lantern luminaries of system wattages of 40 to 50 multiple LED with lens optics and IP:65 pressure die-cast aluminum housing for effective thermal management, total system lumen efficiency should be >90 lumen/watt or above in cool day light (5700K to 6500J), power factor>0.90, CRI>70 complete with mounting brackets on gate including connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying, installation, testing & commissioning of energy efficient surface/recessed mounted type 20 Watts LED flat panel luminaries of size 295mm x 595 mm(nominal size) including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable from slab to False ceiling including cutting the false ceiling, if required & repairing the damages & making good the same etc as required. The Total system Lumen of 20 Watts LED flat panel should be 3000 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison
Supply and fixing of 400 mm sweep size wall mounted fan complete with inbuilt Electronic Regulator, Blade, wire lead with moulded plug top etc. as required.
Supplying, installation, testing & commissioning of energy efficient 1200 mm sweep size, ceiling fan, including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 ampers modular socket outlet and 15/16 ampers modular switch, connection, painting etc as required.
Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade in following manner etc. as required. (a) 3 x 6 sq.mm on wall surface
Less Credit of following electrical accessories etc. complete as required. (a) Assorted PVC copper cable.
(b) Scrap iron / conduit / box
(c) 1200/1400 mm sweep size ceiling fan
(d) Wall mounted fan
(e) LED luminaries
CHETAN ENTERPRISES
SUGANDHA ELECTRICAL
Classic Refrigeration Works
Shaka Electrical (India)
Batra Engineers
M/s Bhagwat Associates
A K Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .