| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.6 LAccepted-AOC 160 PREM NAGAR BAREILLY | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹15.2 L+₹23,334.50 (1.56%)Rejected-Finance 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹17.4 L+₹2.5 L (16.5%)Rejected-Finance | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹18.3 L+₹3.3 L (22.4%)Rejected-Finance | L-4 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹37,400
Closing Date
3 Apr 2021, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
REPAIRS TO PLASTER, JOINERY, ROOF TREATMENT, PLINTH PROTECTION, HARDSTANDING, DRAIN, RETAINING WALL ETC. AT AF STATION BHOWALI AND LKT UNDER GE (AF) BAREILLY
2021_MES_428743_1
8573 / E8
Open Tender
Civil Works
Item Rate
180 days
Bhowali, Nainital
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹37,400
Yes
27 May 2021
6 Mar 2021
6 Apr 2021
6 Mar 2021
3 Apr 2021
20 Mar 2021
Amount
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius using old size bricks built in cement mortar (1:4) all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc. 15cm thickness (below or above ground level) all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in surface channel and drains etc complete all as specified.
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Add or deduct for each 25mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
M&L for providing plain cement concrete type B1, 1:2:4 using 20mm graded aggregate as in lintels up to 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, copings, bed plates etc complete including necessary formwork all as specified.
M&L for 75mm thick cement concrete PCC 1:3:6 type C2 using 40mm graded aggregate as in flooring/ hard standing/ plinth protection finishing even and smooth without using extra cement
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified and as directed
M&L for preparation of new plastered surfaces of walls & applying two coats of cement based paint all as specified and as directed.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in any type of soil.
M&L for plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, sub base for flooring etc. all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC) any section, embedded in concrete, brick work, masonry etc. including taking out embedded portion and making good disturbed surfaces all as directed.
Dismantling fencing wire mesh, any type
Excavating in post holes (or similar holes) each n.exc. 0.5cu.m., getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc. 25cm, watering, and removing surplus soil to a distance n.exc. 50m and making good surface in hard/ dense soil all as specified.
M&L for mild steel work in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, any dia/ length all as specified.
Supply only Chain link MS galvanized fencing, any size or type all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire all as specified and as directed.
S&F in repairs Galvanized 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) all as specified.
Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10 meter openable length, having 50 Nos rounds per 6 metre length (before stretching), on ‘Y’ shaped angle iron brackets placed 2.4m to 3.00m apart, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, with reinforced barbed tape (R.B.T.)/ spring core (2.5mm thick) wire of high tensile strength of 165 kg/sq.cm with tape (0.52mm thick) and weight 43.478 gm/m complete all as specified and as directed including taking down existing rusted coil. Notes: (i) Angle iron supports shall be measured and paid separately under relevant items of Schedule ‘A’ (ii) Measurement shall be made for stretched length.
Supply only mild steel round bars of any dia in required lengths as in line wires for chain link fencing conforming to Fe-290 Gde-E-165 all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W (Gde-E- 250), quality-A all as specified.
Engagement of tire mounted excavator with back hoe (JCB) for clearing the earth from land slide/ snow fall and disposing the same as directed including crew and fuel complete time to time as ordered by the Engineer-in-Charge.
S&F in repairs fancy type PVC coated mild steel 20mm dia medium grade curtain rods complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Mild steel coloured brackets with PVC decorative dome for curtain rods complete all as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as directed.
Dismantling timber scantlings 40sq.cm and over in section, un-framed, in any position all as specified.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe.410-W. (Gde-E-250, Quality-A) complete all as specified.
M&L for preparation of new or previously untreated steel/ iron surfaces of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
S&F pre-painted Galvalume corrugated steel sheets of 0.50mm thick [Galvalume base-PPGL sheets] of approved colour and profile, fixed with self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed.
All as per Item No. 32 herein before but plain sheet as in eves trim, rake trim and closure trim, valley rain water gutter, down spouts and top rafters etc.
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc. complete all as specified.
All as per Item No. 34 herein before but plain sheet as in eves trim, rake trim and closure trim, valley rain water gutter, down spouts and top rafters etc.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar all as specified.
M&L for granite (of any type) tiles 18 to 20mm thick machine cut, laid over and including 15mm thick screed bed in CM 1:6, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in flooring complete all as directed.
M&L for granite (of any type) tiles 18 to 20mm thick machine cut, in skirting/ dado laid over and including 10mm thick cement screed in CM 1:3 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
M&L for non skid coloured ceramic joint free tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18sq.m but n.exc. 0.38sq.m, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in CM (1:4) complete all as specified.
M&L for non skid coloured ceramic joint free tiles 7 to 8mm thick (square/ rectangular) in skirting cut from tiles of size exc. 0.18sq.m but n.exc. 0.38sq.m, to suit the size of floor tile, set and jointed in neat cement slurry and pointed in coloured cement to match. laid over and including backing coat of 10mm thick in CM (1:3) complete all as specified.
M&L for glazed digitally printed ceramic tiles of size 300x450mm, 6 to 7mm thick in vertical surfaces of wall, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 10mm thick backing coat in CM 1:3 complete all as specified.
Taking down chowkats or frames with shutters (with out taking off shutters from frames) n. exc. 1.5sq.m. each all as specified.
Taking down chowkats or frames with shutters (with out taking off shutters from frames) exc. 1.5sq.m. but n. exc. 4sq.m. each all as specified.
S&F of aluminium windowss made of powder coated aluminium sections of approved colour, sliding type three track window or ventilator with sliding shutter and frame with and including aluminium grill, 5 mm thick tinted glass and mosquito proofing net as detailed below complete all as specified and directed: - (i) Frame made of section size 92 X 31.75 X 1.30 mm as suitable for bottom, top and sides of window. (ii) Shutter for top, bottom and side rails 40 X 18 X 1.29 mm. (iii) Glass 5 mm thick one side reflective glass and other side visible fixed with rubber gasket and aluminium clips of suitable size, 4 Nos. aluminium hold fasts with each window and necessary handles, tower bolt etc. as directed. (iv) Aluminium grill made of 5 mm dia powder coated aluminium section as per design No. DG-102 of make DEDO grill or design No. A-103 duly fixed with aluminium section 50 X 20 X 1.5 mm size. (v) Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of aperture 1.40 mm duly fixed with tined tacks or galvanised wire staples.
S&F of door frame with partially glazed shutter made of aluminum section powder coated of approved colour with 5.5 mm thick one side reflective glass and partially paneled with panel made of 5 mm thick PVC composite board duly fixed with aluminium clips comprising of the following complete as specified and directed:- (i) Door frame (Chowkat) made of section size 100 x 40 x 2 mm thick. (ii) Styles of shutter made of section size 85 x 44.45 x 3 mm thick. (iii) Top rail made of section size 95.25 x 44.45 x 1.7 mm thick. (iv) Middle rail made of section size 83.50 x 44.75 x 1.7 mm thick. (v) Bottom rail made of section size 114.30 x 44.15 x 1.7 thick. (vi) Glazing aluminium clips made of 0.70 mm thick section. (vii) 2 Nos. Handle Powder coated Aluminium 200 mm long as approved. (viii) Tower bolt having dia of bolt 9.90 mm dia and 200 mm long. (ix) Mortise lock 100 mm size, 7 Livers of make: Godrej. (x) Hold fast aluminium 100 mm long- 4 Nos/Each frame. (xi) One No. Floor door spring with each shutter. (xii) 1 No. 300 mm long sliding door bolt of Aluminium duly Powder coated.
S&F of door frame with partially glazed shutter made of aluminum section powder coated of approved colour with 5.5 mm thick one side reflective glass and partially paneled with panel made of 5 mm thick PVC composite board duly fixed with aluminium clips comprising of the following complete as specified and directed:- (i) Door frame (Chowkat) made of section size 100 x 40 x 2 mm thick. (ii) Styles of shutter made of section size 85 x 44.45 x 3 mm thick. (iii) Top rail made of section size 95.25 x 44.45 x 1.7 mm thick. (iv) Middle rail made of section size 83.50 x 44.75 x 1.7 mm thick. (v) Bottom rail made of section size 114.30 x 44.15 x 1.7 thick. (vi) Glazing aluminium clips made of 0.70 mm thick section. (vii) 2 Nos. Handle Powder coated Aluminium 200 mm long as approved. (viii) Tower bolt having dia of bolt 9.90 mm dia and 200 mm long. (ix) Mortise lock 100 mm size, 7 Livers of make: Godrej. (x) Hold fast aluminium 100 mm long- 4 Nos/Each frame. (xi) One No. Floor door spring with each shutter. (xii) 1 No. 300 mm long sliding door bolt of Aluminium duly Powder coated.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified.
All as per Item No. 48 herein before but except stone
M&L for providing precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to match
M&L for flush pointing to random rubble masonry, uncoursed or brought up to courses in CM (1:4) complete all as specified.
Extra over stone walling of granite or trap stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface n.exc. 40mm complete all as specified.
Removing mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified
M&L for Broken stone or boulders including hand packing (any thickness) at back side of weep holes and raising or lowering to the required level all as specified.
S&F Low density poly ethylene pipes (LDPE) 50mm bore of pressure rating 6kg/cm² laid in retaining wall as in weep holes complete all as specified
M&L for PCC 100mm thick type D2 (1:4:8) using 40mm graded aggregate as in sub-base for flooring/ hard standing complete all as specified.
Supply and laying 80mm thick Machine Pressed Precast Concrete M-40 Grade, Interlocking Paver Blocks, PVC mould reflective type conforming to IS - 15658 of any shape and size with Grey cement and pigment complete laid on and including 50mm compacted thick sand bed all as specified and as directed.
M&L for heavy duty coloured vitrified tiles of size 300x300 or 400x400mm, 10 to 12mm thick, scratch proof high grip tiles used for high traffic parking/ pathways, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in CM (1:4) complete all as specified. [Make: High traffic Super grip series of make: Johnson Endura or equivalent in Kajaria/ Orient]
M&L for pre-polished coloured chequered cement concrete tiles of size 300x300mm, 25mm thick, set, jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles laid over and including 20mm thick screed bed in CM 1:4 complete all as specified.
M&L for 75mm thick cement concrete PCC 1:2:4 type B2 using 40mm graded aggregate as in flooring/ hard standing/ plinth protection finishing even and smooth without using extra cement
M&L for 75mm thick cement concrete PCC 1:2:4 type B2 using 40mm graded aggregate as in flooring/ hard standing/ plinth protection finishing even and fair with spike rolling to surface or making impressions of expanded metal, whilst the concrete is green all as specified and as directed.
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade-A all as specified.
Removing building materials etc. other than spoil to a distance exc. 500m but n.exc. 1.0 km beyond the lead included in the rates, including loading, unloading and stacking at the destination
M&L for River sand filling under floors or in foundations including watering and consolidation all as specified. [Note: Thickness after consolidation shall be considered for payment]
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25cm in any type of soil.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
M&L for 50mm thick cement concrete PCC 1:2:4 type B1 using 20mm graded aggregate as in flooring/ hard standing/ plinth protection finishing even and smooth without using extra cement
S&F plastic dividing strips 48mm wide, 1.5mm thick, inserted in position, conform to design all as specified and as directed.
M & L for applying one coat of bituminous primer @ 0.30 Litres per Sqm including cleaning and preparation of plastered or RCC surface, as in sunken portion complete all as specified and directed.
M & L for applying evenly a tack coat of industrial bitumen 85 / 25 @ 1.20 Kg per Sqm including cleaning of surface, as in sunken portion complete all as specified and directed.
M & L for polythene film, black, 50 micron thick laid in floors/ DPC all as specified and as directed.
M & L for providing plain cement concrete, type E-2, 1:5:10 (using 40 mm graded stone aggregate) as in filling or mass concrete in any position complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators, partitions etc. with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty/ glazing clips in any size all as specified and as directed.
M & L for providing roof treatment comprising of the following specifications complete all as specified and directed: - (i) Rendering 15 mm thick cement plaster in cement mortar 1:3 mixed with and including polymer based water proofing compound over leveling course of concrete, when the concrete is still green. (ii) Applying a coat of bituminous primer @ 0.30 Liters per Sqm over fully dried plastered surface. (iii) Applying a coat of hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg per Sqm to the entire roof surface over primed surface. (iv) Laying of polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film and standard weight 3 Kg per Sqm with minimum 100 mm side and end laps as per manufacture’s instructions and strict supervision of manufacturer’s technical representative.
Taking down existing roof treatment of any description including brick tiles and cleaning the surface by scrubbing and washing with water and disposing the rubbish off the premises and stacking the serviceable brick tiles for reuse complete all as directed.
M&L for 40mm thick brick tiles laid and bedded in 15mm thick CM (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement all as specified
All as per Item No. 77 herein before but except brick tiles
Dismantling wall and ceiling boards (fibre, pulp, insulation, PVC etc.) any thickness, including cover fillets and frame work.
Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having knurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre all as specified and as directed.
M&L for Anodized aluminium snap grid frame work of size 605 x 605mm using standard sections such as wall angle of size 38x25x2.4mm weighing 0.36 kg/m, main/ cross tees of size 36.5x25x1.4mm weighing 0.24 kg/m for false ceiling including provision of 6mm dia. G.I. wire suspenders complete all as specified and as directed.
S&F Hangers 6mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete for ceiling grid of size 605x605mm all as
S&F 4mm thick non asbestos fibre cement boards of size 600x600mm fixed in ceiling with clips to aluminium snap grid complete including
S&F PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and as directed
M&L for vitrified tiles, light shade, first quality of size 600x600mm, 9 to 10mm thick as in Floors, set and jointed in cement slurry, finished with flush pointing in coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M&L for vitrified tiles, light shade, first quality for skirting cut from tiles of size 600x600mm, 9 to 10mm thick, to suit the size of floor tile, set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles over and including backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc. to receive plaster
M&L for rendering in two coats, 10mm thick each in CM (1:4) including mixing water proofing compound in top coat on concrete/ brick masonry surfaces, finished even and smooth without using extra cement all as specified and as directed. (NOTE :Supply only water proofing compound shall be measured and paid separately under relevant item.)
Supply only integral water proofing compound
M&L for rendering 5mm thick in CM 1:3 on surfaces of ceiling finished even and smooth without using extra cement.
M&L for preparation of new plastered surfaces of walls & applying two coats of distemper oil emulsion over a coat of alkali resistant primer all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified.
Taking down PVC SWR drain pipes, jointed in solvent cement from any location all as directed.
S&F PVC (SWR) pipe 110mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as directed.
S&F in repairs PVC (SWR) bends 110mm bore, any radius complete all as directed.
S&F in repairs PVC (SWR) vent cowls 110mm bore complete all as directed.
S&F in repairs PVC (SWR) bends 110mm bore, any radius without access door complete all as directed.
S&F in repairs 110mm bore PVC (SWR) junction, single (Single T) equal or un equal
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified.
S & F of 5 mm thick and 35 mm wide PVC sheet fillet for fixing of wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of solid PVC Wall Lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
om enterprises
M M CONSTRUCTIONS
NOORI ENTERPRISSES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .