Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
24 May 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (T) UC
DGM (Technical) UC, The FACT, Udyogamandal, Cochin, Kerala
Opening, Boxing-up and Gasket replacement of Heat Exchanger end cups and other mechanical works in Lactam plant of FACT Petro UC.
2023_FACT_752017_1
5061/2023-2024/E27311
Limited
Miscellaneous Works
Item Rate
25 days
Udyogamandal
This tender is issued on limited tender basis and offers shall be accepted from the vendors on whom the enquiry is issued. Vendors interested in getting our future enquiries may contact DGM Projects and Planning -UC FACT Udyogamandal
5 documents required · 5 mandatory
₹0
₹12,000
Yes
25 May 2023
9 May 2023
25 May 2023
9 May 2023
24 May 2023
9 May 2023
Opening, Boxing-up and Gasket replacement of Heat Exchanger end cups and other mechanical works in Lactam plant of FACT Petro UC.
Opening and boxing up of the end cups of Heat Exchanger E- 7102 Ammonium sulphate circulation cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7106 Anone stripper after condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7201 Rearrangement cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7202 Neutralisation cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7303 Benzene distillation cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7302 Benzene distillation condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7315 Benzene stripper cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7317 Stripper after condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7401 IE feed cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7604 Evaporative 3rd stage condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7605 condenser cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7606 Evaporation 2nd step ejector condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7701 HW cooler in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7103 A.S Preheater in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7706 Surface condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7707 Surface condenser in Lactam plant.
Opening and boxing up of the end cups of Heat Exchanger E- 7708 Surface Condenser in Lactam plant.
Unbolting and Re-bolting, replacing of gaskets, leak testing of flange joints, dummies, manholes etc. with various pressure ratings in petro plant. Scope includes flange face Cleaning, gasket cutting and boxing up in leak proof manner. (Rate per bolt / stud to be quoted) Bolt / stud size # from M12 up to and including M20.
Unbolting,& Re bolting, replacing of gaskets, leak testing of flange joints, dummies, manholes etc. with various pressure ratings in petro plant. Scope includes flange face cleaning, gasket cutting, and boxing up in leak proof manner. (Rate per bolt / stud to be quoted) Bolt / stud size # above M20 up to and including M36
Unbolting, & Re-bolting, replacing of gaskets, leak testing of flange joints, dummies, manholes etc. with various pressure ratings in petro plant. Scope includes flange face cleaning, gasket cutting, and boxing up in leak proof manner. (Rate per bolt/stud to be quoted) Bolt/stud size – above M36 up to and including M56
INFANT JESUS SMITH AND ENNG WORKS
GOPAKUMAR E A
Mak engineering enterprises
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .