GEMC-511687762526073
Awarded to GSP POWER PROJECTS RETAIL DIVISION
₹2.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| DG SET 5 KVA 1PH MECH & ITC -MAHINDRA POWEROL- GSP RETAIL | MAHINDRA & KD441-GSI2 | - | 1 NOS | ₹2.4 L | 242,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.4 LQualified Make: MAHINDRA GSP RETAIL
Model: MAHINDRA & KD441-GSI2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: MAHINDRA GSP RETAIL
Model: MAHINDRA & KD441-GSI2 | ₹2.4 L | L1 | Qualified MSE, Category: General |
| 2 | L2₹2.5 L+₹7,000 (2.89%)Qualified Make: Ashok leyland
Model: ASHOK LEYLAND LP 5D CHANDRASEKHARPUR BHUBANESWAR ODISHA 751016 INDIA | KHORDHA | ODISHA | 751016 | Make: Ashok leyland
Model: ASHOK LEYLAND LP 5D | ₹2.5 L+₹7,000 (2.89%) | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
₹12,500
Closing Date
6 Sept 2018, 11:00 amClosed
diesel generators- DG Sets Average Turn Over of Last 3 Years 8 Lakh (s) Experience with Gov. Required 1 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 5 5 (or higher) No of Phase - Single phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No
if applicable - * Type of Engine cooling Air Cooled Air Cooled Type of governer Mechanical Mechanical
Electronic (or higher) Class of governer A2 A2 1/4 (or higher) Number of cylinders (nos) 1 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 5 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 86 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 1 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 (or higher) Thickness of Foam 30 * Density of Foam for sound insulation 32 * Noise level at 1 meter (dB) 74 * BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles * 2/4 Battery capacity (Ah) - * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory No * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory No * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 1 1.0
2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Premjit Tripathy 762001
CDM & PHO Office
Near Medical Square
Phulbani
Kandhamal
Odisha 1 15
515194
GEM/2018/B/73100
GeM Contract
diesel generators- DG Sets
GeM Contract
15 days
Odisha; Kandhamal
PRODUCT
Awarded to GSP POWER PROJECTS RETAIL DIVISION
₹2.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| DG SET 5 KVA 1PH MECH & ITC -MAHINDRA POWEROL- GSP RETAIL | MAHINDRA & KD441-GSI2 | - | 1 NOS | ₹2.4 L | 242,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Average Turn Over of Last 3 Years 8 Lakh (s) Experience with Gov. Required 1 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 5 5 (or higher) No of Phase - Single phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No | - | - | - |
| if applicable - * Type of Engine cooling Air Cooled Air Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic (or higher) Class of governer A2 A2 1/4 (or higher) Number of cylinders (nos) 1 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 5 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 86 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 1 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 (or higher) Thickness of Foam 30 * Density of Foam for sound insulation 32 * Noise level at 1 meter (dB) 74 * BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles * 2/4 Battery capacity (Ah) - * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory No * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory No * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 1 1.0 | - | - | - |
| 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Premjit Tripathy 762001 | - | - | - |
| CDM & PHO Office | - | - | - |
| Near Medical Square | - | - | - |
| Phulbani | - | - | - |
| Kandhamal | - | - | - |
| Odisha 1 15 | - | - | - |
₹12,500
6 Sept 2018
24 Aug 2018
contract_GEMC-511687762526073.pdf
GEM_CONTRACT • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_515194.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .