| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.8 L+₹1.9 L (4.89%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance L2 | |
| 3 | L3₹40.3 L+₹2.4 L (6.23%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹41.2 L+₹3.2 L (8.39%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L4 | Rejected-Finance L4 | |
| 5 | L5₹41.7 L+₹3.7 L (9.80%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINT OF LT DISTRIBUTION SYSTEMS AND CONNECTED PANEL, BUS BAR CHAMBER AT TECHNICAL AREA UNDER GE (AF) JAMNAGAR NO 1
2022_MES_545835_1
8174/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹80,000
Yes
19 Nov 2022
17 Aug 2022
16 Sept 2022
17 Aug 2022
15 Sept 2022
8 Sept 2022
Amount
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 300 sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 240 sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 185 sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 120 sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 95 sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 70 sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 50 Sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 35 Sqmm 3.5 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 Sqmm 4 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 16 Sqmm 4 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 4 core including cable cover & GI Tubing if any all as specified and directed.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 6 sqmm 4 core including cable cover & GI Tubing if any all as specified and directed.
Laying only including re-routing if any , LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 300 sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 240 sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 185 sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 120 sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 95 sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 70 sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 50 Sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 35 Sqmm 3.5 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 25 Sqmm 4 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 16 Sqmm 4 core all as specified and directed.
Laying only including re-routing if any, LT underground cable in trenches, ducts, poles, tubes etc, aluminium conductor of size 10 sqmm 4 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 4 core all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm 4 core all as specified and directed.
Excavation trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of cables and erectioning of poles and getting out in any soft /loose soil all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3 mtr in depth for foundation pole in Hard/ Dense soil [including interlocking tiles,hardcore,soling of roads,paths,Mecadam surfaces of any description(water bound,grouted,tarmac),lime concrete,stone masonary in lime concrete] and getting out all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3 mtr in depth for foundation pole in Soft / disintegrated rock (including plain cement concrete and stone masonary in cement mortar) and getting out all as directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25cm in soft/loose soil all as specified and directed.
Removing the excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed .
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009) for measurement purpose thickness of sand after punning down will be considered.)
Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
Laying only PCC cable cover for LT UG cable, of any description retrieved from item No 01 to 11, all as specified and directed by Engr-in-Charge.
Laying only Steel Tubes (of any bore & size) laid in trenches/wall for protection of underground cables complete all as specified & directed. Note : - Serviceable tubes retrieved from Sl item No. 01 to 12 herein before shall be laid under this item. Quoted rates is deemed to be inclusive of replacement of fittings / fixtures, if any
S&F 40 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches / wall for protection of underground cable when crossing the road complete.
S&F 50 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches / wall for protection of underground cable when crossing the road complete.
S&F 80 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches / wall for protection of underground cable when crossing the road complete.
S&F 100 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches / wall for protection of underground cable when crossing the road complete.
Boring under roads / pavement / hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including provision of HDPE pipe of 100 to 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. (Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost).
Supply and fix in repair MCCB 100 Amp, Four Pole, breaking capacity 15/16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 125 Amp, Four Pole, breaking capacity 15/16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 160 Amp, Four Pole, breaking capacity 15/16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 200 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 250 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 400 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, adjustable thermal and fixed magnetic setting type , fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 500 to 630 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, adjustable thermal and fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2/4 core, 16 to 25 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35/50 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70/95 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 240 to 300 Sqmm all as specified and as directed by Engineer-In-Charge.
Material and labour for provision of earthing in replacement complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip 32 x 6 mm size by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore .....
.........galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) and RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing of earthing on completion complete all as specified & directed. Note:- Quoted rates shall be deemed to include for earth strip with protection pipe upto 7.5 M length.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried on ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc including all fittings & fixtures as required, 25x4 mm size galvanized iron strip
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried on ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc including all fittings & fixtures as required 32x6 mm size galvanized iron strip complete all as specified and directed.
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, conforming to IS-5039 with IP 54 proction, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings, floor mounted with PCC 1:2:4 type B1 platform, nut bolts, ......./-
.....washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Pnel board with all accessories all as specified and as directed comprising the following:-(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeves of capacity of 400 Amps for phases and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty spoxy insulation in seoparate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral. (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(Make:-Siemens/L&T/Telematic or Equivalent ISI marked). (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors.
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete.(b) PCC 1:3:6 platform with angle iron frame for mounting LT panel 1.2m above ground level, all as directed by Engineer in Charge. (c) LT Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed by Engg-in- Charge.
(a) MCCB 320 Amps,415V, 4 POle, 35 KA - 01 No (In coming)
(b) MCCB 250 Amps, 415V, 4 pole, 25 KA - 01 Nos (Out going)
(c) MCCB 100 Amps, 415V, 4 Pole, 16 KA - 02 Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, conforming to IS-5039 with IP 54 proction, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings, floor mounted with PCC 1:2:4 type B1 platform, nut bolts, ........
.........washers etcfor grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Pnel board with all accessories all as specified and as directed comprising the following:-(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeves of capacity of 600 Amps for phases and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty spoxy insulation in seoparate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral . (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(Make:-Siemens/L&T/Telematic or Equivalent ISI marked). (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors.
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete.(b) PCC 1:3:6 platform with angle iron frame for mounting LT panel 1.2m above ground level, all as directed by Engineer in Charge. (c) LT Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed by Engg-in- Charge.
(a) MCCB 250 Amps,415V, 4 POle, 35 KA - 01 No (In coming)
(b) MCCB 200 Amps, 415V, 4 pole, 25 KA - 01 Nos (Out going)
(c) MCCB 63 Amps, 415V, 4 Pole, 16 KA - 04 Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, conforming to IS-5039 with IP 54 proction, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings, floor mounted with PCC 1:2:4 type B1 platform, nut bolts, ........
.........washers etcfor grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Pnel board with all accessories all as specified and as directed comprising the following:-(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeves of capacity of 400 Amps for phases and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty spoxy insulation in seoparate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & hase to neutral . (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(Make:-Siemens/L&T/Telematic or Equivalent ISI marked). (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors.
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete.(b) PCC 1:3:6 platform with angle iron frame for mounting LT panel 1.2m above ground level, all as directed by Engineer in Charge. (c) LT Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed by Engg-in- Charge.
(a) MCCB 400 Amps,415V, 4 POle, 35 KA - 01 No (In coming)
M&L for Painting of LT Panels (including frames above GL),all internal & external surface including complete removal of Existing painting and applying two coats of synthetic enamel paint over one coat of Ferrous resistant pimer complete all as specified and directed including Disconnecting & connecting the LT panel for painting.
M&L for Repairing of damaged LT Panels Boxes by replacement of Hinges,aldrop bolts and minor parts etc and prevent leakage from top of panel including welding of door and frames and greasing of hinges,aldrops etc complete all as specified and directed by Engg-in-charge including Disconnecting & connecting the LT panel for repairing.
Note: (i) LT cables If any fault occurs upto completion of contract peried should be attended by concerned rep within stripulated time frame without any failure , quoted rates is deemed to be included all such charges.(ii) Item no 1 to 69 If any above LTcable and connected itms become breakdown, the contractor shall loacate the problem/fault at site within 12 hours on intimation by JE/Engineer-In-Charge and ensure that the fault and rectified within 48 Hours , failing which an amount of Rs 200 /- per hour will be recovered as penal recovery from any payment due to contractor after expiry of 48 hours.)
JAMNAGAR ELECTRIC AND MACHINERY CO
Sukhi Electricals
M/s SK Traders
rajengineers
MADHAV ENTERPRISE
SURESH ELECTRICALS
Rameshwar Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .