Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 16 280 KALYANI NADIA WEST BENGAL 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L1 | Accepted-AOC AOC | |
| 2 | L2₹4.6 L+₹28,540 (6.68%)Rejected-Finance 6 GOODS SHED ROAD TITAGARH KOLKATA 700119 | TITAGARH | NORTH 24 PARGANAS | WEST BENGAL | 700119 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹5.8 L+₹1.5 L (35.5%)Rejected-Finance SIMURALI NADIA | PURBA BARDHAMAN | WEST BENGAL | 713502 | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹7,890
Closing Date
1 Oct 2024, 3:45 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
SITC of AC machine and allied work for newly constructed on duty rest room at Nabadwip SGH RATTIRER SATHI
2024_WBPWD_758245_1
WBPWD/EE/NED/Short NIQ/e-T/51/ (1st Call)24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,890
19 Nov 2024
26 Sept 2024
3 Oct 2024
26 Sept 2024
1 Oct 2024
26 Sept 2024
Amount
A. SITC of single-phase split AC Machines
Supply & delivery of 230 V, 50 Hz 2.5-ton capacity [BEE- 2 star rated (minimum); EFR(W/W:- 3.10] split type A.C. Machine fitted with fixed speed scroll compressors with copper made cooling coil, material for body of indoor unit ABS, nominal cooling capacity: (KCAL/Hr.): 7500, Min. guaranteed cooling capacity (KCAL/Hr.):7500, Moisture removal capacity, minimum room discharge Air Flow (CFM.): 925, with Remote etc. to complete without plug top (Make: O General / Mitsubishi Heavy / as per direction of EIC) SPLIT AC - 2.5 TR - OGENERAL ASGA30FUTD-B (R410A).
Installation, testing & commissioning of 2.5 Tr. Split-type AC both indoor/outdoor units incl. S& F of 40 mm x 40 mm x 5 mm MS angle iron frame for installation of ODU and sealing of the holes in the wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending well the damages as per direction of EIC.
Supply & laying of 9.38 mm (3/8") dia & 15.63 mm (5/8") dia Refrigerant Copper Pipe (Minimum thickness 0.7 mm (Make - Royku /Totaline/Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] and also raping the insulation & Copper wire with GKB Gold non-adhesive tape.
Supply & laying 3 core 4 sq. mm. P.V.C. insulated Copper wire (Make - Havells/Finolex /Polycab/RR Kabel) for connecting the Power hub to ODU as per requirement.
Supply & laying 4 core 2.5 sq. mm. P.V.C. insulated Copper wire (Make - Havells/Finolex/Polycab/RR Kabel) for connecting the ODU to IDU as per requirement.
S & F of flexible PVC high-quality water carrying pipe of the proper size for draining water from already installed AC to any available (nearest) drain water pipe or near ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high-quality sealing gum etc. as reqd. All these arrangements for fixing must be arranged by the agency itself as per the direction of EIC.
B . Shifting of existing AC Machines
Dismantling IDU & ODU of split type A.C machine of Main OT by Co's special tools & tackles including labour as per direction of EIC. (Required Due to construction of Doctor On duty )
Re-installation of dismantled Split & window type AC both indoor/ outdoor unit incl. refixing of MS angle iron frame for installation the same at new location after through checking by Co's own special tools & tackles incld. Labour as per direction of EIC .(Required Due to construction of Doctor On duty)
Supply & changing of strainer/capallary set as required as per direction of EIC.
Supply & refilling of the refrigerant gas R-410A/R32
Purging of cooling and condesor coil with nitrogen gas pressure, detecting leakage point and repairing it by gas welding including complete Flashing the system for gas charging as required.
Supply & laying of 6.25 mm (1/4") dia & 15.63 mm (5/8") dia Refrigerant Copper Pipe (Minimum thickness 0.7 mm (Make - Royku /Totaline/Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] and also raping the insulation & Copper wire with GKB Gold non-adhesive tape.
Supply & Fixing 9 mm thick internal adhesive foam preventing sweating on the surface & Maintaining proper cooling (for all existing AC M/Cs in NSGH)
5/8" dia Nitrel Foam
1/2" dia Nitrel Foam
1/4" dia Nitrel Foam
Tie Lock for proper fixing the above pipe insulation with necy. Other materials & srafholding etc as reqd. as per direction of EIC
Supply & laying 4 core 2.5 sq. mm. P.V.C. insulated Copper wire (Make - Havells/Finolex/Polycab/RR Kabel) for connecting the ODU to IDU as per requirement.
S & F of flexible PVC high-quality water carrying pipe of the proper size for draining water from already installed AC to any available (nearest) drain water pipe or near ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high-quality sealing gum etc. as reqd. All these arrangements for fixing must be arranged by the agency itself as per the direction of EIC. (19 mm dia)
ARATI ENTERPRISE (BID ID -5655464)
LOKNATH ENGINEERING (BID ID -5653936)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .