Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,CSPZ, MLUG Car Parking, Asaf Ali Road, Delhi-110002
Replacement of DG sets in Kasturba Hospital under CSPZ
2024_MCD_186580_1
MCD/TR/9437/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
180 days
City- SP, JAMA MASJID
refer special conditions
2 documents required · 2 mandatory
₹1,180
₹3.9 L
29 Mar 2024
16 Feb 2024
23 Feb 2024
16 Feb 2024
23 Feb 2024
17 Feb 2024
Amount
DG set
OD19382/2023-2024:DSR(5.14) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
OD19383/2023-2024:(DSR 7.6.4) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
OD19384/2023-2024:(DSR 7.5.4) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
OD19385/2023-2024:(DSR 9.1.31) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
OD19386/2023-2024:(DSR14.16.5) Supplying and laying of following size DWC HOPE pipe lSI marked alongwith all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal)
OD19387/2023-2024:Supplying, Installation, testing and commissioning of earth pit of minimum dia. 100 mm size 3 mtr. Deep in hard rock soil, through machine or by any suitable means. Earth electrode consisting of 3 mtr. Long and 50 mm. Dia. Size pur copper earth electrode surrounded by highly conductive black fill compound chemical 2 bags (25 kg each) with necessary masonary encloser for 300 mm x 300 mm size GI earth pit cover complete as required.
OD19388/2023-2024:Supply, Installation, Testing and Commissioning of 500KVA(CPCB-IV+) rating silent DG set comprising of suitable engine coupled to suitable alternator mounted on a common base frame along with other accessories i.e., control panel, fuel tank, battery with leads Complete as required
OD19389/2023-2024:Supply, Installation, Testing and Commissioning of AMF panel suitable for 500 KVA DG setComplete accessories as required
OD19390/2023-2024:Supply, installation, testing and commissioning of DG stack height chimney height 10 meter from floor level such as 250mm pipe thickness 4.85 mm as per IS:3589 jindal make, supporting structure such as ISMC,Isa ,Foundation plate, Joint plate, Lightning arrestor, aviation lamp, civil work for stack height, insulation on exhaust pipe thick 50mm having a density of 96kg/m3 supported by chicken mesh and finally cladded by Aluminium sheet of 26 SWG, SS flexible bellow at the outlet of DG for vibration purpose
cable
122.1.26:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*400 SQMM
civil work
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
Water Power Engg Enterprises
Bidder Name
Water Power Engg Enterprises
VOID FIRE CONSULTANTS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .