Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | ₹5.2 L | L1 | Accepted-AOC agreement executed |
| 2 | Rejected-Technical | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | Kailas Electricals & Power Solutions L1 | JEBIN JOHN MG POWER CONTROLS L2 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | 29 | point | 1,096.7 ₹31,804.30 | 975 ₹28,275 |
| 1.00 | 1.9:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLC PVC insulated copper conductor single core cable etc as required. | 1 | point | 1,573.11 ₹1,573.11 | 1,677.18 ₹1,677.18 |
| 1.00 | OD466482/2025-2026:Supply ,installation,testing and commissioning of 100 Watts LED flood light.
System Wattage 100W
Luminaire Efficacy >120 lm/W
Correlated Colour Temperature 5665K ±355K
Colour Rendering Index >70
Maintenance of Lumen Output 50,000 hrs.
Operating Temperature Range -10°C to 50°C
Beam Angle (±10%) NB-A5 (60°)
Net Weight 4.5Kg. Approx.
Ingress Protection (IP) IP66
Impact Resistance (IK) IK07
Input Voltage 140 to 270V AC
Input Frequency 50 Hz
Power Factor ? 0.95
THD (@240V AC) <10%
Built-in Surge protection 4 kV
External Surge protection 10kV | 4 | each | 7,748.02 ₹30,992.08 | 8,000 ₹32,000 |
| 1.00 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | each | 469.51 ₹939.02 | 490 ₹980 |
| 1.00 | OD466483/2025-2026:
Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)with two year warranty. | 1 | each | 8,799.54 ₹8,799.54 | 8,000 ₹8,000 |
| 1.01 | OD462093/2025-2026:Supply and installation of wall Fan with 3 speed energy saving motor .Sweep (mm):
400mm
Power Input (watts) : 125W , speed : 2100 RPM, Air delivery :105 CMM .Number of blade 3 | 3 | each | 2,274.73 ₹6,824.19 | 2,300 ₹6,900 |
| 1.01 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | 2 | each | 2,105.66 ₹4,211.32 | 2,200 ₹4,400 |
| 1.01 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | 2 | each | 175.43 ₹350.86 | 185 ₹370 |
| 1.01 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 2 | each | 397.96 ₹795.92 | 424 ₹848 |
Updated dates
Tender Value
₹5.5 L
EMD Value
₹13,737
Closing Date
11 Mar 2026, 11:00 amClosed
SE, Kollam municipal corporation
SE, Kollam municipal corporation
Renovation of Townhall -KMC-General Electrical Work
2026_LSGD_843221_7
PC4/16546/25
Open Tender
Electrical Works
180 days
Kollam Municipal Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,215
Yes
₹13,737
Yes
23 May 2026
3 Mar 2026
11 Mar 2026
3 Mar 2026
11 Mar 2026
3 Mar 2026
3 Mar 2026 - 11 Mar 2026
Electrification
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.9:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLC PVC insulated copper conductor single core cable etc as required.
OD466482/2025-2026:Supply ,installation,testing and commissioning of 100 Watts LED flood light. System Wattage 100W Luminaire Efficacy >120 lm/W Correlated Colour Temperature 5665K ±355K Colour Rendering Index >70 Maintenance of Lumen Output 50,000 hrs. Operating Temperature Range -10°C to 50°C Beam Angle (±10%) NB-A5 (60°) Net Weight 4.5Kg. Approx. Ingress Protection (IP) IP66 Impact Resistance (IK) IK07 Input Voltage 140 to 270V AC Input Frequency 50 Hz Power Factor ? 0.95 THD (@240V AC) <10% Built-in Surge protection 4 kV External Surge protection 10kV
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD466483/2025-2026: Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)with two year warranty.
OD462093/2025-2026:Supply and installation of wall Fan with 3 speed energy saving motor .Sweep (mm): 400mm Power Input (watts) : 125W , speed : 2100 RPM, Air delivery :105 CMM .Number of blade 3
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
90.12.2.39:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 6 sq mm
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
OD460271/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (25mm)
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm
OD462198/2025-2026:Supply installation and replacing of 35 Watt Square LED Panel Light, IP Rating: IP44 Shape :Square Wattage: 35 W Lighting Color: Cool White, Warm White, Natural White Color Temperature :3500-4100 K Lighting Type ":LED
OD462246/2025-2026:Supplying, installation and replacing 35W down light at roof top. 35W LED Cob Down Light for Ceiling, 130mm Ceiling Cut Size False Ceiling Light.
OD462199/2025-2026:Supply, conveyance, installation, testing and commissioning of recess mounting 18W down light fittings of all types on ceiling including cutting holes, giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. (LCDEP-12CDL of M/s Crompton / equivalent make)
OD462240/2025-2026:Supply installation testing and commissioning of 18 Watt Round Surface Led Panel Light VOLTAGE: 85V-265V SHAPE: Round BODY COLOR: White
OD462241/2025-2026:Supply 9w LED focus up light IP 66, fixing and giving connection using suitable steel screws
OD462277/2025-2026:Supply installation testing and commissioning of energy-efficient, weather-resistant fixtures 30W Outdoor Gate Light Input Voltage: Standard 85-265V AC, 50/60Hz. Brightness: ~1,125 lumens. Ingress Protection: IP65 rated (waterproof and dustproof).
OD470165/2025-2026:Supply, installation, testing and commissioning of Exide 150AH INVA GOLD Battery 3 year replacement warranty +2 year pro life
OD470167/2025-2026:Supply, installation, testing and commissioning of Exide 3KVA invertor using 2 battery.Replacement warranty 2 Year
OD472594/2025-2026:Providing and fixing double scaffolding system (cup lock type ) on the exterior side , up to seven story height made with 40mm dia . M.S tube 1.5 m centre to centre , horizontal & vertical tubes joining with cup & lock system with M.Stube challies , M.S clamps and M.S staricase system in the scaffolding for working platform etc . and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracing , runners , connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc . complete as per directions and approval of Engineer - in charge .The elevational area of the scaffolding shall be measured for payment purpose . The payment will be made once irrespective of duration of scaffolding . Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. (Reference : Civil price no : 14.72)
OD472715/2025-2026:Supply installation testing and commissioning of 3W LED foot lamps for stairs typically feature durable Aluminum or PVC construction, IP54/IP65 waterproofing for indoor/outdoor use, and 250/300 lumens output, often in warm white (3000K).
OD472756/2025-2026:Supply installation testing and commissioning of 20A 240W 12V-DC STRIP DRIVER
OD472770/2025-2026:Supply installation testing and commissioning of Strip Light Driver 5Amps, Amp Rating: 5A, Input Voltage: AC 80 - 275V, Output Voltage: 12V
OD473232/2025-2026:Supply installation testing and commissioning DC 12V Led strip light. IP Rating: IP67. 12V Constant Voltage. Input Voltage Range: 150V-265 V AC.
OD473271/2025-2026:Supply installation testing and commissioning of 6x4 inch (approx. 150x100 mm) sintex box for electrical fittings with water proof and dust proof protection
OD473272/2025-2026:Supply and fixing MCB Channel
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1423164.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tendernotice_2.pdf
PDF • 0.16 MB
Tendernotice_3.pdf
PDF • 0.02 MB
Tendernotice_4.pdf
PDF • 0.25 MB
Tendernotice_5.pdf
PDF • 0.02 MB
Tendernotice_6.pdf
PDF • 0.03 MB
BOQ_1423164.xls
BOQ • 0.33 MB
townhallelesbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid