Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | Rejected-Technical L2 |
Tender Value
₹8.5 L
EMD Value
₹16,949
Closing Date
12 Aug 2024, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division, Agartala
Annual maintenance repairing of Split type Vertical type Air Conditioning machines at Pragna Bhavan Agartala
2024_CEPWD_51345_1
36_EE_MECHDIVN_AGT_202425
Open Tender
Electrical Works
Works
730 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹16,949
18 Dec 2024
6 Aug 2024
12 Aug 2024
6 Aug 2024
12 Aug 2024
6 Aug 2024
Amount
Providing & Fitting fixing of new PCB Circuit for 2.0 TR inverter AC Indoor unit (same brand with the machine to be repaired) as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of new PCB Circuit for 2.0 TR inverter AC Outdoor unit (same brand with the machine to be repaired) as per the direction of the Engineer-in-charge
Providing, fitting fixing of Evaporator FAN motor of Split AC unit Inverter type (2.0 TR) indoor unit as per direction of the Engineer-in-charge
Providing, fitting fixing of Condenser FAN motor of Split AC unit Inverter type (2.0 TR) Outdoor unit as per direction of the Engineer-in-charge
Providing, fitting fixing of inverter compressor of Split AC unit(2.0 TR) with necessary circuit as per direction of the Engineer-in-charge
Repairing of indoor PCB Circuit for 1.5/2.00 TR as per the direction of the Engineer-in-charge.
Providing & Charging of Non CFC Refrigerant gas to Split AC as per the direction of the Engineer-in-charge.
Leak testing & leak repairing of condensing & evaporator unit by flushing nitrogen for performance and pressure testing etc for 1.5/2.0 TR capacities split type AC's and repair with brazing as per direction of the Engineer-in-Charge..
Providing & fitting fixing of 1” PVC drain Pipe as per the direction of the Engineer-in-charge.
Dismantling and re-installation of Split/vertical type AC machine as per the direction of the Engineer-in-charge.
General Servicing of 1.5/2.00 Tr capacity split AC machines in/c washing cleaning of (Indoor & Outdoor) units both by pressurised water by using Jet pump and servicing Jacket as per direction of the Engineer-In-Charge
Providing remote control unit of Split AC unit(1.5/2.0 TR) with necessary circuit as per direction of the Engineer-in-charge
Providing & fitting fixing of Gas Charging valve (1/4") dia as per direction of the Engineer-in-Charge
Providing & fitting fixing of Gas Charging valve (5/8") dia as per direction of the Engineer-in-Charge.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge
Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable.
Charges for transportation , lifting, lowering & placing at site of Split/window AC units from Office & vice versa for a to & fro trip(Once) as per the Direction of the Engineer-in-Charge
Providing, fitting fixing of Evaporator FAN motor of Vertical AC unit Inverter type (4.00 TR) indoor unit as per direction of the Engineer-in-charge.
Providing, fitting fixing of Condenser FAN motor of Vertical AC unit Inverter type (4.00 TR) outdoor unit as per direction of the Engineer-in-charge.
Providing & Fitting fixing of new Electronics Circuit sets for 4.00 TR Vertical AC both Indoor & Out door unit (same brand with the machine to be repaired) as per the direction of the Engineer-in-charge.
Providing, fitting fixing of inverter compressor of Vertical type AC unit(4.0 TR) with necessary circuit as per direction of the Engineer-in-charge
Providing, fitting fixing of Contractor for Vertical type AC machine for 3.0 TR/ 4.0 TR as per direction of the Engineer-in-charge
Supply installation testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF/VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as below for Suction and Liquid lines, all accessories as per specification etc as required: a) 15.86 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
b) 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Comprehensive Annual maintenance contract for 03(Three) nos 80 ltr storage capacity water cooler & water purifier for a period of two years including timely changing of iron removal filter & necessary accesories on half yearly basis as per direction of the Engineer-in-Charge
ARABINDA DATTA (BID ID -146775)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_52214.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .